DIAGNOSTIC TEST PROGRAM

The Diagnostic Test Program is designed to be an aid for authorized service technicians to objectively test the washer’s water fill valves, drain pump and the clutch/brake solenoid, drive motor, water level sensor, lid switch, LEDs and rotary switches. There are four tests in the program all accessed from the control panel by following a specified entry sequence. NOTE: Check the Tech Sheet provided with the washer for most recent test sequences.

Entry Sequence

The entry sequence to begin the Diagnostic Test Program is as follows:

1.Set the TEMP SELECT switch for the desired test according to the following table:

Table 7

 

TEST

TEMP SELECT

 

SETTING

 

 

 

 

Actuator and Switch Test

 

Hot/Cold (HC)

 

(PREFERRED SERVICE TEST)

 

 

 

 

 

 

 

 

 

Automatic Operations Test

 

Cold/Cold (CC)

 

 

 

 

 

Interface Test*

 

Warm/Warm (WW)

 

 

 

 

 

*Interface Test

 

available on 4-temperature models

2.Unplug the washer power cord from the household outlet for more than five seconds.

3.Plug the washer back into the electrical power outlet.

4.Set the CYCLE SELECT switch so the flat on the stem faces position 1 - Knob points to the right. (Fig. 30)

 

Permanent

Off

 

Super

 

Press

Wash

Fig. 30

Delicate

Cottons:

 

Heavy

 

 

 

Soak

Cottons:

 

 

Normal

 

 

Spin Only

Flat of Shaft

5.Press and hold the START/PAUSE button while turning the CYCLE SELECT switch one step clockwise.

6.Release the START/PAUSE button.

NOTE: To terminate any diagnostic test and return to normal operation, unplug the washer power cord from the power outlet for more than five seconds and then plug the power cord back into the outlet.

61

Page 69
Image 69
Whirlpool 4322616 manual Diagnostic Test Program, Entry Sequence