DIAGNOSTIC TEST PROGRAM
The Diagnostic Test Program is designed to be an aid for authorized service technicians to objectively test the washer’s water fill valves, drain pump and the clutch/brake solenoid, drive motor, water level sensor, lid switch, LEDs and rotary switches. There are four tests in the program all accessed from the control panel by following a specified entry sequence. NOTE: Check the Tech Sheet provided with the washer for most recent test sequences.
Entry Sequence
The entry sequence to begin the Diagnostic Test Program is as follows:
1.Set the TEMP SELECT switch for the desired test according to the following table:
Table 7
| TEST | TEMP SELECT | |
| SETTING | ||
|
|
| |
| Actuator and Switch Test |
| Hot/Cold (HC) |
| (PREFERRED SERVICE TEST) |
| |
|
|
| |
|
|
|
|
| Automatic Operations Test |
| Cold/Cold (CC) |
|
|
|
|
| Interface Test* |
| Warm/Warm (WW) |
|
|
|
|
| *Interface Test |
|
available on
2.Unplug the washer power cord from the household outlet for more than five seconds.
3.Plug the washer back into the electrical power outlet.
4.Set the CYCLE SELECT switch so the flat on the stem faces position 1 - Knob points to the right. (Fig. 30)
| Permanent | Off |
| Super | |
| Press | Wash |
Fig. 30 | Delicate | Cottons: |
| Heavy | |
|
| |
| Soak | Cottons: |
|
| Normal |
|
| Spin Only |
Flat of Shaft
5.Press and hold the START/PAUSE button while turning the CYCLE SELECT switch one step clockwise.
6.Release the START/PAUSE button.
NOTE: To terminate any diagnostic test and return to normal operation, unplug the washer power cord from the power outlet for more than five seconds and then plug the power cord back into the outlet.
61