Actuator and Switch Test (Set TEMP SELECT: Hot/Cold - Initiate Entry Sequence) (Preferred Service Test)
The Actuator and Switch Test is designed to detect malfunctions in the transmission, water inlet valves, pump, solenoid and clutch, and the lid switch. Each function is tested separately by turning the TEMPERATURE SELECT switch as indicated in Table 8. Press the START/PAUSE button to start and end each test.
Opening and closing the lid during any of the these tests will verify the lid switch.
NOTE: CYCLE SELECT setting has no effect on the Actuator and Switch Test.
TEMP SELECT
POSITION
WATER LEVEL
SWITCH
ACTION
|
| Pump and Brake Solenoid |
|
| |
|
|
|
|
|
|
|
| HC | n/a | Pump & Solenoid | |
|
| Actuate | |||
|
|
|
| ||
|
| Agitate Function |
|
|
|
|
|
|
|
|
|
Table 8 | WC | n/a | Dry Agitate | ||
|
|
|
|
|
|
|
| Water Inlet System & Water Level Switch | |||
|
|
|
|
|
|
|
| CC | Empty | Warm Fill | |
|
|
|
|
| |
|
| Full | Agitate | ||
|
|
| |||
|
| Spin Function |
|
|
|
|
|
|
|
| |
|
| WW* | Empty | Pump & Brake | |
|
| (This setting only | Solenoid | ||
|
| on |
| Actuate, Spin | |
|
| models) | Full | Pump & Brake | |
|
|
| Solenoid | ||
|
|
|
| ||
|
|
|
| Actuate | |
|
|
|
|
|
|
To terminate this test and return to normal operation, unplug the washer power cord from the power outlet for more than five seconds and then plug the power cord back into the outlet.
Automatic Operations Test (Set TEMP SELECT: Cold/Cold - Initiate Entry Sequence)
The Automatic Operations Test checks LEDs, Valves, Solenoid, Pump and both Drive Motor Windings by turning each component on for approximately three seconds.
| STEP | 3 SECOND OPERATIONS |
|
|
|
|
|
| 1 | Wash Cycle/Status LED on |
|
|
|
|
|
| 2 | Rinse Cycle/Status LED on |
|
|
|
|
|
| 3 | Spin Cycle/Status LED on |
|
|
|
|
|
| 4 | Cold Water Valve |
|
|
|
|
|
Table 9 | 5 | Hot Water Valve |
|
|
|
|
|
| 6 | Motor Lead - Yellow |
|
|
|
|
|
| 7 | Motor Lead - Red |
|
|
|
|
|
| 8 | Pump and Solenoid |
|
|
|
|
|
| 9 | All OFF |
|
|
|
|
|
| 10 | Return to Step 1 |
|
|
|
|
|
To terminate this test and return to normal operation, unplug the washer power cord from the power outlet for more than five seconds and then plug the power cord back into the outlet.