Fluff Air Cycle

The Fluff Air Cycle provides up to 30 minutes of unheated drying time.

CLEAN TOUCH CONTROL PAD

The clean touch control pad provides push button control of the following operations:

TEMPERATURE SELECTION - Four levels of temperature ranging from Extra Low to High.

FINISH GUARD - Allows this option to be turned On or OFF.

CYCLE SIGNAL - Allows this option to be turned On or OFF.

PUSH-TO-START KNOB

This knob must be pushed to start the dryer. The door must be closed for the dryer to operate. If the door is opened during any drying cycle, the dryer will not operate again until the Push-to-Start knob is pushed again.

“C” VERSION ELECTRONIC DRYER CONTROL

The “C” version dryer control system consists of an electronic control board located in the console area and a moisture sensor attached to the lint screen grille inside the dryer drum. The dryer control system measures the resistance across the moisture sensor during the automatic dry cycle. The electronic control board turns power to the timer motor on and off based on input from the moisture sensor.

Theory of Operation

When a cycle is selected, Timer Switch 1 will be closed. This applies 120VAC through the orange/ white wire to the electronic control board. Timer Switch 0 will be open if the selected cycle is not a timed dry cycle, so there is no alternate path for current flow through the timer motor. (Fig. 4-2)

W/BK

T/W

Fig. 4-2