6 Maintenance
6.3 8365/8390 PERIODIC MAINTENANCE
This section describes the periodic maintenance required for this machine. This maintenance helps ensure stable image quality. In the periodic maintenance, some service parts may be checked, cleaned, or replaced. Perform periodical inspections according to the table below.
N Action
1Clean wipers
2Tubing Flush and maintenance station cap flush
3Clean the edges of the caps in maintenance station
4Clean the area around the caps
5Clean around the bottom of the heads
6Replacing the sponge in the spitting box
7Replacing the wipers
8Replacing upper sponge at back of the capping station
Notes
Frequency
Daily maintenance
Weekly maintenance
Monthly maintenance
•All cleaning in “Ink areas” must be done with Xerox 8365/8390 cleaning solution.
•Above maintenance cycle is based on use:
8 hours / day, 5 days / week and 44 weeks / year.
If machine is used more, maintenance periods will come earlier.
Available kits for the end user and their order numbers
5.User and good shape kit for 6 months
No | Description | Quantity |
1 | Sponge plate | 6 |
2 | Wipers | 24 |
3 | Spitting box sponge | 12 |
4 | Cleaning Liquid 250 ml | 3 |
5 | Instruction sheet | 1 |
6 | Good shape kit | 1 |
6.Good shape kit
No | Description | Quantity |
1 | Gloves | 300 |
2 | Pipette | 12 |
3 | Swabs | 150 |
4 | Polyknit wiper | 300 |
7.Solvent cleaning in a bottle
112 | 8265/8290/8365/8390 User Guide |