ZyXEL Communications 480 manual Filter Rules Summary Menus, Abbreviations Description Display

Models: 480

1 240
Download 240 pages 53.25 Kb
Page 146
Image 146

Prestige 480 Dual BRI ISDN Router

 

 

Menu 21.1 - Filter Rules Summary

 

# A Type

Filter Rules

M m n

-

- ----

-------------------------------------------- --------- - - -

1

Y IP

Pr=6, SA=0.0.0.0, DA=0.0.0.0, DP=137

N D N

2

Y IP

Pr=6, SA=0.0.0.0, DA=0.0.0.0, DP=138

N D N

3

Y IP

Pr=6, SA=0.0.0.0, DA=0.0.0.0, DP=139

N D N

4

Y IP

Pr=17, SA=0.0.0.0, DA=0.0.0.0, DP=137

N D N

5

Y IP

Pr=17, SA=0.0.0.0, DA=0.0.0.0, DP=138

N D N

6

Y IP

Pr=17, SA=0.0.0.0, DA=0.0.0.0, DP=139

N D F

Enter Filter Rule Number (1 -6) to Configure:

Figure 9-3 Menu 21.1 - Filter Rules Summary

 

 

Menu 21.2 - Filter Rules Summary

 

# A Type

Filter Rules

M m n

-

- ----

-----------------------------------------------------

- - -

1

Y IP

Pr=17, SA=0.0.0.0, SP=137, DA=0.0.0.0, DP=53

N D F

2

N

 

 

3

N

 

 

4

N

 

 

5

N

 

 

6

N

 

 

Enter Filter Rule Number (1 -6) to Configure: 1

Figure 9-4 Menu 21.2 - Filter Rules Summary

9.2.1 Filter Rules Summary Menus

The preceeding screens show summaries of the existing rules in the filter set. The following tables contain a

brief description of the abbreviations used in Menu 21.1and Menu 21.2.

Table 9-1 Abbreviations Used in the Filter Rules Summary Menu

Abbreviations

Description

Display

 

 

 

#

Refers to the filter rule number (1-6).

 

 

 

 

A

Refers to Active.

[Y] means the filter rule is active.

 

 

 

9-4

Filter Configuration

Page 146
Image 146
ZyXEL Communications 480 manual Filter Rules Summary Menus, Abbreviations Used in the Filter Rules Summary Menu