ZyXEL Communications P-202 manual Backup, Restore and Upload 10-3

Models: P-202

1 128
Download 128 pages 47.57 Kb
Page 111
Image 111

Prestige 201 ISDN Access Router

Step 1. Use telnet from your workstation to connect to the Prestige and log in. Because TFTP does not have any security checks, the Prestige records the IP address of the telnet client and accepts TFTP requests only from this address.

Step 2. Put the SMT in Command Interpreter (CI) mode by entering 8 in Menu 24 – System Maintenance.

Step 3. Enter command “sys stdio 0” to disable the SMT timeout, so the TFTP transfer will not be interrupted. Enter command “sys stdio 5” to restore the five-minute SMT timeout (default) when the file transfer is complete.

Step 4. Launch the TFTP client on your workstation and connect to the Prestige.

Step 5. Go to SMT menu 24.5. Note that you must remain in this menu until backup is complete.

Step 6. Use the TFTP client to transfer files between the Prestige and the workstation. The file name for the configuration file is “rom-spt”.

Note that the telnet connection must be active and the SMT in CI mode before and during the TFTP transfer. For details on TFTP commands, please consult the documentation of your TFTP client program. For UNIX, use “get” to transfer from the Prestige to the workstation, and “binary” to set binary transfer mode.

Backup, Restore and Upload

10-3

Page 111
Image 111
ZyXEL Communications P-202 manual Backup, Restore and Upload 10-3