Prestige 201 ISDN Access Router

8.6.1 Call Control Parameters

Menu 24.9.1 - Call Control Parameters

Dialer Timeout:

Digital Call(sec)= 60

Retry Counter= 0

Retry Interval(sec)= N/A

Press ENTER to confirm or ESC to Cancel:

Figure 8-15 Call Control Parameters

 

Table 8-5 Call Control Parameters Fields

Field

Description

Dialer Timeout:

The Prestige will timeout if it can not set up an outgoing digital call

Digital Call (sec)

within the timeout value. The default is 60.

Retry Counter

How many times a busy or ‘no answer’ telephone number is retried

 

before it is put on the blacklist. The default is 0 and the blacklist

 

control is not enabled.

Retry Interval

Elapsed time after a call fails before another call may be retried.

(sec)

This applies before a telephone number is blacklisted.

System Maintenance

8-15

Page 99
Image 99
ZyXEL Communications P-202 manual Call Control Parameters Call Control Parameters Fields