Chapter 5 Initial Setup Example

3Since the VLAN2 network is connected to port 1 on the Switch, select Fixed to configure port 1 to be a permanent member of the VLAN only.

4To ensure that VLAN-unaware devices (such as computers and hubs) can receive frames properly, clear the TX Tagging check box to set the Switch to remove VLAN tags before sending.

5Click Add to save the settings to the run-time memory. Settings in the run-time memory are lost when the Switch’s power is turned off.

5.1.4Setting Port VID

Use PVID to add a tag to incoming untagged frames received on that port so that the frames are forwarded to the VLAN group that the tag defines.

In the example network, configure 2 as the port VID on port 1 so that any untagged frames received on that port get sent to VLAN 2.

Figure 26 Initial Setup Network Example: Port VID

1Click Advanced Applications and VLAN in the navigation panel. Then click the VLAN Port Setting link.

2Enter 2 in the PVID field for port 1 and click Apply to save your

changes back to the run-time

memory. Settings in the run-timeEXAMPLE memory are lost when the

Switch’s power is turned off.

 