2.— Pull the Cables (at the input locations) The following cables need to be installed:
•CAT 5 cables for signal transmission from the AV wall plates to the PVS 305SA IP
NOTES:
• For PVT RGB D IP Plus four CAT 5 cables (two for video input and two for LAN) are needed, and for PVT RGB D wall plates, two CAT 5 signal cables for each input are needed.
• Maximum distance from the
PVS 305SA to the Wallplate is 100 feet.
The optimum distance is between 50 and 75 feet. Minimum distance is 15 feet.
• CAT 5 cables supplied are terminated to the TIA 568A standard. Other CAT 5 cables can be used if they are TIA 568A or 568B standards and terminated to the same standard at both ends.
•CAT 5 cables (included) for MLC network connection.
•PoleVault switcher communication cable from the MediaLink controller (MLC
•Projector communication cables from the MediaLink controller (IR Serial Comm, 50 feet, part number
a.Drill cable pathways through any obstructions (for example, wall caps,
b.Label the CAT 5 signal cables at both ends with the supplied labels.
c.Pull the cabling through the wall from the ceiling space down to the location of the transmitters and other wall devices, and out through the openings.
TIP: Secure cables with cable clamps to |
provide strain relief. |
Signal Cable | Label color |
|
|
RGB 1A (Input 1 RGB) | Orange |
RGB 1 B (Input 1 RGB) | Orange |
|
|
RGB 2A (Input 2 RGB) | Yellow |
RGB 2B (Input 2 RGB) | Yellow |
|
|
RGB 3A (Input 3 RGB) | Magenta |
RGB 3B (Input 3 RGB) | Magenta |
|
|
RGB 4A (Input 4 RGB) | Light Green |
RGB 4B (Input 4 RGB) | Light Green |
|
|
Video 3 (Input 3 Composite Vid) | Dark Green |
|
|
Video 4 (Input 4 Composite Vid) | Red |
|
|
NOTE: Fasten the colored section to the cable first, then wrap the clear section around it.
RGB #1A
ÉUse the supplied labels for clear cable identification during installation.
ÎPull the cables at each location.