Panasonic IMC80A Driver Voltage, Outline Rated Output Reactor Part No, Inductance Rated

Page 37

[Reference]

Reactor

Driver

Voltage

 

 

 

Figure 1

Specification

 

 

 

Outline

Rated Output

Reactor Part No.

Figure

 

Frame

for Power

 

Source of

 

 

 

 

Code

 

 

 

 

Driver

 

 

 

 

 

 

 

 

 

 

Single-

50 - 100W

DV0P227

1

 

 

phase

 

 

100V

 

 

 

 

MKDE

Single-

50 - 100W

 

 

 

phase

 

 

 

 

 

 

 

 

200V

 

DV0P220

2

 

 

Three-

50 - 200W

 

 

 

 

 

 

phase

 

 

Figure 2

 

200V

 

 

 

 

Single-

200W

DV0P228

1

 

 

phase

 

 

100V

 

 

 

 

MLDE

Single-

200 - 400W

 

 

 

phase

 

 

 

 

200V

 

DV0P220

2

 

 

Three-

400W

 

 

 

 

 

 

phase

 

 

 

 

200V

 

 

 

 

2-I

 

E

C

D

 

A

4-H

F

(Mounting dimension)

 

(Mounting

 

dimension)

BG

X Y Z

NP

R S T

6-IE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

C

 

 

 

 

 

 

 

 

 

 

A

4-H

F

(Mounting dimension)

 

(Mounting

 

dimension)

B

 

G

Figure

Part No.

A

B

C

D

E

F

G

H

I

Inductance

Rated

(mH)

Current (A)

 

 

 

 

 

 

 

 

 

 

 

1

DV0P227

55

80

68

90

90

41

55

ø 7

M4

4.02

5

DV0P228

2

8

 

 

 

 

 

 

 

 

 

 

2

DV0P220

65

125

83

118

145

70

85

Width 7 x Length 12

M4

6.81

3

The former Agency of Natural Resources and Energy of Ministry of International Trade and Industry (present Ministry of Economy, Trade and Industry) established higher harmonics suppression guidelines in September 1994.

(1)Drivers rated 4kW or lower are subject to “Higher Harmonics Suppression Guidelines for Home Electric and General Purpose Appliances”.

(2)Drivers rated over 4kW are subject to “Higher Harmonics Suppression Guidelines for High Voltage and Special Customers”.

The Ministry of Economy, Trade and Industry strongly demands manufacturers to enforce measures to curb harmonics.

In order to comply with the established regulatory level, connect a power-factor improvement reactor (L) to drivers of 4 kW or lower. For drivers of over 4kW, determine the level of harmonics according to the guideline and take a suppression measure, as appropriate.

<Reference>

[Harmonics Suppression Technical Guideline], JEAG 9702-1995, Japan Electric Association

[Harmonic Current Calculation Procedure for General-purpose Inverter at Special Customers], JEM-TR201-1996,

Japan Electrical Manufacturers’ Association

Reference

191

Image 37
Contents Reference Installing Panaterm on Hard Disk Outline of PANATERM, Setup Support SoftwareSteps of Procedure Connection MethodStarting Panaterm ReferenceOutline of Communications CommunicationsConnection of Communications Line Communications SpecificationRS232C Communications List of User Parameters Related to Communications Communications MethodHandshaking Code Line Control Transmission Sequence Transmission ProtocolProtocol Parameter Configuration of Data BlockExample of Data Communication Example of Changing Parameters Waiting for EOT State Transition Diagram RS232C CommunicationsCommunications Timing RS232C Communications Details on Communications Commands List of Communications Commands167 168 Reference 170 171 172 173 174 175 176 177 Description on Dividing/Multiplier Ratio Example EC Directives Conformance to EC Directives/UL StandardsEMC Directives Applicable StandardsEnvironment PowerCircuit Breaker Peripheral EquipmentSurge Absorber Noise FilterGrounding Noise Filter for Signal cablesLeakage Breaker Conformance to UL StandardsMINAS-E Series Table of Junction Cable by Model Optional PartsJunction Cable for Encoder Junction Cable for Motors Robotop 600V DPWire rod Connector Kits for Power Supply of the DriverName NumberManufacturer Wire rod Connector Kits for Connection of Motor and EncoderName Manufacturer’s part No Number Remarks Pin arrangement of connector for junction of encoder cable Interface Cable for Connection with Host Controller Connector Kit for Connection with Host Controller Number Manufacturer Remarks PANATERM, software for communications control Communications Cable Connection with Personal ComputerConsole External Regenerative Resistor Manufacturer’s Specification Remarks Ohmic ValueDIN Rail Mounting Unit Driver Voltage ReactorOutline Rated Output Reactor Part No Inductance RatedSurge Absorber for Motor Brake Recommended PartsList of Manufacturers of Peripheral Equipment Motor Surge Absorber for Motor BrakeDimensional Outline Drawing Output 50W, 100W 230mm 200W, 400W 220mm Motor Muma Series 50W to 400WSpecification of Keyed Version Operation Allowable Load of Output ShaftThrust Load Direction BMotor Characteristics S-T Characteristics Reference Servo Motor with Gear How to check the modelChecking Model of Servo Motor with Gear Check the Combination of Driver and Motor with Gear Incremental Specification 2500 P/rApplicable Motors with Gear Applicable Drivers Servo Motor with Gear Dimensional Outline Drawing of Motor with GearDetailed View of Shaft End Allowable Load of Output Shaft of Servo Motor with Gear Requests Concerning Installation200V 200W 100VDriver Internal Control Block DiagramDriver Motor SpecificationsZEROSPD/TC Warn Hit-and-stop InitializationLoad Pressing Control Hit-and-stop Initialization and Load Pressing ControlIndex Encoder Incremental specification 2500P/r 211 Recommended Parts Surge Absorber for Motor Brake 192 213 Reference Memo Repair After-Sale Service RepairElectronic data of this manual