Hit-and-stop Initialization and Load Pressing Control

Load Pressing Control

 

 

 

 

 

 

 

 

Example of Application

 

 

 

 

 

 

 

 

 

 

PrNo.

Name

Example of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06

ZEROSPD/TC input

2

 

Press-fit Machine

 

 

 

 

 

 

 

 

 

 

 

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09

Warning output selection

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5E

Torque limit set-up

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

1st over-speed level

3000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

set-up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

2nd torque limit set-up

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

2nd over-position

10000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

deviation set-up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

73

2nd over-speed level

3000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

set-up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)

 

(2)

 

 

 

(3)

 

 

 

 

 

(4)

 

(5)

 

 

 

 

 

 

Pin 5 (ZEROSPD/TLC

On

 

: Torque limit switching input)

 

On

Pin 11 (WARN

:Under Torque limit output)

The value of second torque limit

(+)

Torque

(–)

 

 

 

 

B

(+)

A

Search Speed

(Low Speed)

 

Command

 

 

(–)

 

C = A + B

 

 

Distance for which the motor has not

moved is held in the deviation counter

(+)

Motor Rotation Speed

(–)

 

 

 

 

(1)

(2)

(3)

(4)

(5)

208

Image 54
Contents Reference Steps of Procedure Outline of PANATERM, Setup Support SoftwareInstalling Panaterm on Hard Disk Connection MethodReference Starting PanatermCommunications Outline of CommunicationsCommunications Specification Connection of Communications LineRS232C Communications Communications Method List of User Parameters Related to CommunicationsHandshaking Code Transmission Sequence Transmission Protocol Line ControlConfiguration of Data Block Protocol ParameterExample of Data Communication Example of Changing Parameters State Transition Diagram RS232C Communications Waiting for EOTCommunications Timing RS232C Communications List of Communications Commands Details on Communications Commands167 168 Reference 170 171 172 173 174 175 176 177 Description on Dividing/Multiplier Ratio Example EMC Directives Conformance to EC Directives/UL StandardsEC Directives Applicable StandardsCircuit Breaker PowerEnvironment Peripheral EquipmentNoise Filter Surge AbsorberLeakage Breaker Noise Filter for Signal cablesGrounding Conformance to UL StandardsJunction Cable for Encoder Optional PartsMINAS-E Series Table of Junction Cable by Model Junction Cable for Motors Robotop 600V DPName Connector Kits for Power Supply of the DriverWire rod NumberConnector Kits for Connection of Motor and Encoder Manufacturer Wire rodName Manufacturer’s part No Number Remarks Pin arrangement of connector for junction of encoder cable Connector Kit for Connection with Host Controller Interface Cable for Connection with Host ControllerNumber Manufacturer Remarks Communications Cable Connection with Personal Computer PANATERM, software for communications controlConsole Manufacturer’s Specification Remarks Ohmic Value External Regenerative ResistorDIN Rail Mounting Unit Outline Rated Output Reactor Part No ReactorDriver Voltage Inductance RatedList of Manufacturers of Peripheral Equipment Recommended PartsSurge Absorber for Motor Brake Motor Surge Absorber for Motor BrakeDimensional Outline Drawing Motor Muma Series 50W to 400W Output 50W, 100W 230mm 200W, 400W 220mmSpecification of Keyed Version Thrust Load Allowable Load of Output ShaftOperation Direction BMotor Characteristics S-T Characteristics Reference How to check the model Servo Motor with GearChecking Model of Servo Motor with Gear Incremental Specification 2500 P/r Check the Combination of Driver and Motor with GearApplicable Motors with Gear Applicable Drivers Dimensional Outline Drawing of Motor with Gear Servo Motor with GearDetailed View of Shaft End Requests Concerning Installation Allowable Load of Output Shaft of Servo Motor with Gear100V 200V 200WDriver Internal Diagram Control BlockSpecifications Driver MotorHit-and-stop Initialization ZEROSPD/TC WarnHit-and-stop Initialization and Load Pressing Control Load Pressing ControlIndex Encoder Incremental specification 2500P/r 211 Recommended Parts Surge Absorber for Motor Brake 192 213 Reference Memo After-Sale Service Repair RepairElectronic data of this manual