Leica CM1950 manual Optional Accessories, Ordering Information

Page 53

11. Optional Accessories

11.1 Ordering Information

 

Specimen disc ø 20mm assembly

0477 43739

Specimen disc ø 30mm assembly

0477 40044

Specimen disc ø 40mm assembly

0477 40045

Specimen disc ø 55mm assembly

0477 40046

Specimen disc 80x50mm, assembly

0477 43714

O-ring blue (10 pieces), 20 mm

0477 43247

O-ring red (10 pieces), 20 mm

0477 43248

O-ring blue (10 pieces), 30 mm

0477 43247

O-ring red (10 pieces), 30 mm

0477 43248

O-ring blue (10 pieces), 40 mm

0477 43249

O-ring red (10 pieces), 40 mm

0477 43250

O-ring blue (10 pieces), 55 mm

0477 43251

O-ring red (10 pieces), 55 mm

0477 43252

Blade holder base complete

0477 40351

Blade holderextension CE-BB, complete

0477 43005

Insert for low-profile blades for blade holder CE, complete

0477 42488

Finger rest, complete

047740387

Anti-roll plate 70 mm - 50μm spacer

0477 42491

Anti-roll plate 70 mm -100μm spacer

0477 42492

Anti-roll plate 70 mm -150μm spacer

0477 42493

Glass insert 70mm, polished

0477 42497

Knife holder base assembly

0477 42359

Knife holder CN assembly

0477 42358

Knife support CN short

0477 42380

Knife support CN

0477 42370

Knife holder attachment CNZ, assembly

0477 42363

Anti-roll plate assembly glass 50mm

0419 33981

Heat and cold extractor, assembly

0477 41039

Cold extractor, assembly

0477 43737

Heat extractor, assembly

0477 43126

Leica CM1950 – Cryostat

53

Image 53
Contents Leica CM1950 Page Page Table of contents 12.1 11.112.2 12.3Important Information Symbols Used in This Manual and Their MeaningQualification of Personnel Designated UseUnpacking and Installation Safety and DesignGeneral Safety Instructions Opening the packaging Removing the packaging Ramp assemblyTransport to the Installation Location Microtome knives Safety FeaturesSecuring/Locking the Handwheel Knife guardCleaning, Disinfection Turning the Instrument Back On Removal of the Microtome MaintenanceHandling Specimens Defrosting Technical Data Refrigeration system CM1950, 50 Hz CM1950, 60 Hz Technical DataSet of filters 5 pieces Standard DeliveryHandwheel, motorized General Overview Control Panel Fields and Cryostat Chamber Site Requirements InstallationRight side Left sideTransport to the Site Assembling the Handwheel Emergency-stop function active, or Locking/Unlocking the HandwheelCentering the Handwheel Optional Only for instruments sold in Japan Selecting the frequency Connection to Power Supply SystemExisting power system Installation Shelf, Movable Optional Installing the Storage Systems Optional For reasonsInserting the Section Waste Tray Section waste tray with the a Cutout a facing the userInstalling the Heat Conductor Block, Stationary Optional Installation Mark for suction nozzle Control Panel Fields on the CM1950 Control Panel Field Instrument Controls12 o’clock Position 6 o’clock 0μm Retraction20.0μm 60.0μmBrief press of the button retracts the specimen by 20μm Coarse feed functionsMotion continues as long as the button is held Sectioning modes Control panel 3 Motorized sectioning optionalLeica Cryofect is not available in all countries Disinfection Duration 30min Duration 180 minTurning the Instrument On Working with the InstrumentConfiguring the Parameters Working with the Instrument Working with the Instrument Manual defrosting of the specimen cooling Entering the trimming thickness Working with the Precooled Cryostat 8.4.1 Preparatory Work Trimming with Extraction Anti-roll Guide Installed Handwheel position 12 3 o’clock, valve open all the way Shut off VAC LED in VAC button goes out Cutting with Extraction Anti-roll Guide installedSpeed Extract. value 1μm 5 μm 40% 60% 80% 100% 10μm Speed10μm 40% 60% 80% 100% 20μm 30μm 40μm Working with the Instrument Problem Causes Remedies TroubleshootingProblems During Work Cryochamber Sections tear Alternately Longer sufficient Tissue type Chamber temperature Temperature Selection Chart in minus COrdering Information Optional AccessoriesCryofect, VPE Leica Cryofect 4x 350ml With anti-roll guide When using low-profile blades, the rulerLever 6 for the lateral shift Lever 7 for clamping the bladeBlade holder CE with finger rest for NB + BB Inserting the blade into knife holder CE Will result Unscrew the bolts 35 of the pressure plate Cleaning the knife holder CE Daily cleaningNot Visible Optional Accessories Anti-roll guide system Optional Accessories Specimen discs in various dimensions Optional Accessories General Maintenance Maintenance and CleaningChanging Fuses Replacement of the Lamp/UVC Lamp Installation of the new lamp Decontamination Certificate master This equipment has been cleaned and decontaminatedNB Microtome knives must be in boxes Yes No indicated belowBU Return Authorization Number EC Declaration of Conformity Anne De Greef-Safft President Biosystems DivisionWarranty and Service Peoples Republic of China