TMS32020
SPRS010B Ð MAY 1987 Ð REVISED NOVEMBER 1990
absolute maximum ratings over specified temperature range (unless otherwise noted)²
Supply voltage range, VCC³ | . ± 0.3 | V to 7 V |
Input voltage range | . ± 0.3 | V to 7 V |
Output voltage range | . ± 0.3 | V to 7 V |
Continuous power dissipation | . . . . . . . . | . . 2 W |
Operating | . . . 0°C to 70°C | |
Storage temperature range | ± 55°C to 150°C |
²Stresses beyond those listed under ªAbsolute Maximum Ratingsº may cause permanent damage to the device. This is a stress ratingonly, and functional operation of the device at these or any other conditions beyond those indicated in the ªRecommended Operating Conditionsº section of
this specification is not implied. Exposure to
recommended operating conditions
|
|
| MIN | NOM | MAX | UNIT | |
|
|
|
|
|
|
| |
VCC | Supply voltage | 4.75 | 5 | 5.25 | V | ||
VSS | Supply voltage |
| 0 |
| V | ||
VIH | All inputs except CLKIN | 2 | VCC + 0.3 | V | |||
CLKIN | 2.4 | VCC + 0.3 | V | ||||
|
| ||||||
VIL | All inputs except CLKIN | ± 0.3 |
| 0.8 | V | ||
|
|
|
|
| |||
CLKIN | ± 0.3 |
| 0.8 | V | |||
|
|
| |||||
|
|
|
|
|
|
| |
IOH |
|
| 300 | ∝A | |||
IOL |
|
| 2 | mA | |||
TA | Operating | 0 |
| 70 | °C |
NOTES: 1. Case temperature (TC) must be maintained below 90°C. 2. RθJA = 36°C/Watt, RθJC = 6°C/Watt.
electrical characteristics over specified
| PARAMETER | TEST CONDITIONS | MIN | TYP§ | MAX | UNIT |
VOH | VCC = MIN, IOH = MAX | 2.4 | 3 |
| V | |
VOL | VCC = MIN, IOL = MAX |
| 0.3 | 0.6 | V | |
IZ | VCC = MAX | ±20 |
| 20 | ∝A | |
II | Input current | VI = VSS to VCC | ±10 |
| 10 | ∝A |
|
| TA = 0°C, VCC = MAX, fx = MAX |
|
| 360 | mA |
ICC | Supply current | TA = 25°C, VCC = MAX, fx = MAX |
| 250 |
| mA |
|
| TC = 90°C, VCC = MAX, fx = MAX |
|
| 285 | mA |
CI | Input capacitance |
|
|
| 15 | pF |
CO | Output capacitance |
|
|
| 15 | pF |
§ All typical values for ICC are at VCC = 5 V, TA = 25°C.
ADVANCE INFORMATION
This device contains circuits to protect its inputs and outputs against damage due to high static voltages or electrostatic fields. These circuits have been qualified to protect this device against electrostatic discharges (ESD) of up to 2 kV according to
should be placed in conductive foam. In a circuit, unused inputs should always be connected to an appropriated logic voltage level, preferably either VCC or ground. Specific guidelines for handling devices of this type are contained in the publication Guidelines for Handling
POST OFFICE BOX 1443 • HOUSTON, TEXAS 77001 | 21 |