Toshiba STE 58760 instruction manual -1-17-

Page 25

STE 58760

Fig. 1.4 Maximum System Configuration

1-17

Image 25
Contents Industrial Robot SR Series START-UP Manual - i - Preface For Euporean Union EU - iv - Table of Contents Changing File DATA・・・・・・・・・・・・・・・・・・・・ Backing UP FILES・・・・・・・・・・・・・・・・・・・・・ Overview Chapter Before Operating SR Series Robot- 1-2 - - 1-3 - - 1-4 - PTP - 1-6 - - 1-7 - - 1-8 - Outline of Operational Procedure -1-10- Specifications -1-12- -1-13- Coordinate System -1-15- System Configuration -1-17- -1-18- -1-19- STE -1-20- Control Panel Names and Functions of SR7000 ControllerFault LED Power LEDTeach Pendant -1-24- -1-25- -1-26- STE -1-27- -1-28- Chapter Power on to Manual Guidance Cold Starting Turning on Main Power- 2-3 - Edit Load Save Testrun Reset Next Hot Starting - 2-6 - - 2-7 - Setting Controller Environmental Conditions Turning the Servo Power on Manual Guidance of Each Axis -2-11- -2-12- Manual Guidance Operation -2-14- -2-15- Motion Range Limit Setting Joint Limit Values by TeachingFormat Verify Zerop Jlimit Channel Next Jlimit Travel Joint Negative Positive NextChannel Next Setting Joint Limit by Numeric Value Entry-2-19- Travel Joint Negative Positive Turning OFF Servo Power Turning OFF the PowerTurning OFF the Main Power -2-22- -2-23- Setting Date Setting Date and TimeDate Date Time Next Date Time Next Setting TimeTime Date Time Next - 3-5 - Changing File Data Edit CONSTRUC.SYS Edit Load Save Testrun Reset Next - 3-8 - - 3-9 - -3-10- -3-11- Outline of Data Setting the System Configuration-3-13- File Format Specify for Gravity Compensation Servo Free ModeConstruction of MANIPULATER. =0WITHOUT,=1WITH Type of JOINT=0LINEAR.=1ROTATE, 1ST Joint to 5THMode of Serial Channel Specify for External File Selection SignalMode of Channel COM1 Mode of Channel COM2Mode of AIR Driven Axis Specify for USE or not USE -3-17- Details of Data -3-19- -3-20- -3-21- Host PRT=HOST -3-24- -3-25- Signals Used for Selecting File Setting External Selection FilesContents of File -3-28- Batch File Batch Processing-3-30- LOADPRO1 LOADPRO2 LOADPRO3 LOADPRO4 Loadpros LOADPRO6 Automatic Execution FileSelect PRO1 Using Batch Processing EffectivelyLoadconstruc .SYS LOADSYSTEM. PAR LOADUSER. PAR LOAD*. PRO -3-33- Program Execution Environment Program Execution Environment-3-35- Resetting Execution Environment Reset Timing of Program Execution Environment Robot Coordinate Systems Setting Coordinate System-3-39- System and the original coordinate system unit deg Teaching Coordinate Data-3-41- Program Sample Move P1 Move P2 END -3-43- -3-44- -3-45- Selecting Coordinate System in Data Editor Mode -3-47- Righty Z,C,TLefty -3-49- -3-50- -3-51- -3-52- Selecting Coordinate System in Utility Mode Robot Utility Work Tool Where Signal Memory -3-55- Timing of Changing Coordinate System Selecting Coordinate System Using Robot Language