STE 58760

Example)

An example of a batch processing which reads files from a floppy disk.

File name: FLOAD. BAT

LOADPRO1

LOADPRO2

LOADPRO3

LOADPRO4

LOADPROS

LOADPRO6

To execute the above batch file, enter the following from the teach pendant.

[F] [L] [O] [A] [D] [Exec]

When the batch processing is executed, the controller reads the file PRO1 to PRO6 from a floppy disk to the RAM drive in the controller.

Note 1)

In the external automatic mode, batch files cannot be executed from the teach pendant.

Note 2)

As opposed to selecting a program, batch files cannot be selected or executed using external input signals.

Note 3)

Unless a batch file is in the controller RAM drive, it cannot be executed.

3.5.2Automatic Execution File

A batch file which is executed just after the controller power is turned on is called an automatic execution file. The contents of the automatic execution file are just like any other batch file, although the file name of the automatic execution file is AUTOSTR. BAT.

The automatic execution file can be used to select a file in the external automatic mode. For details of how to edit files, see 3.2, "Changing File Data".

3-31

Image 90
Contents Industrial Robot SR Series START-UP Manual - i - Preface For Euporean Union EU - iv - Table of Contents Changing File DATA・・・・・・・・・・・・・・・・・・・・ Backing UP FILES・・・・・・・・・・・・・・・・・・・・・ Chapter Before Operating SR Series Robot Overview- 1-2 - - 1-3 - - 1-4 - PTP - 1-6 - - 1-7 - - 1-8 - Outline of Operational Procedure -1-10- Specifications -1-12- -1-13- Coordinate System -1-15- System Configuration -1-17- -1-18- -1-19- STE -1-20- Names and Functions of SR7000 Controller Control PanelPower LED Fault LEDTeach Pendant -1-24- -1-25- -1-26- STE -1-27- -1-28- Chapter Power on to Manual Guidance Turning on Main Power Cold Starting- 2-3 - Edit Load Save Testrun Reset Next Hot Starting - 2-6 - - 2-7 - Setting Controller Environmental Conditions Turning the Servo Power on Manual Guidance of Each Axis -2-11- -2-12- Manual Guidance Operation -2-14- -2-15- Setting Joint Limit Values by Teaching Motion Range LimitFormat Verify Zerop Jlimit Channel Next Next Jlimit Travel Joint Negative PositiveSetting Joint Limit by Numeric Value Entry Channel Next-2-19- Travel Joint Negative Positive Turning OFF the Power Turning OFF Servo PowerTurning OFF the Main Power -2-22- -2-23- Setting Date and Time Setting DateDate Date Time Next Setting Time Date Time NextTime Date Time Next - 3-5 - Changing File Data Edit CONSTRUC.SYS Edit Load Save Testrun Reset Next - 3-8 - - 3-9 - -3-10- -3-11- Setting the System Configuration Outline of Data-3-13- Construction of MANIPULATER. =0WITHOUT,=1WITH Specify for Gravity Compensation Servo Free ModeFile Format Type of JOINT=0LINEAR.=1ROTATE, 1ST Joint to 5THMode of Channel COM1 Specify for External File Selection SignalMode of Serial Channel Mode of Channel COM2Mode of AIR Driven Axis Specify for USE or not USE -3-17- Details of Data -3-19- -3-20- -3-21- PRT Host=HOST -3-24- -3-25- Setting External Selection Files Signals Used for Selecting FileContents of File -3-28- Batch Processing Batch File-3-30- Automatic Execution File LOADPRO1 LOADPRO2 LOADPRO3 LOADPRO4 Loadpros LOADPRO6Using Batch Processing Effectively Select PRO1Loadconstruc .SYS LOADSYSTEM. PAR LOADUSER. PAR LOAD*. PRO -3-33- Program Execution Environment Program Execution Environment-3-35- Resetting Execution Environment Reset Timing of Program Execution Environment Setting Coordinate System Robot Coordinate Systems-3-39- Teaching Coordinate Data System and the original coordinate system unit deg-3-41- Program Sample Move P1 Move P2 END -3-43- -3-44- -3-45- Selecting Coordinate System in Data Editor Mode -3-47- Z,C,T RightyLefty -3-49- -3-50- -3-51- -3-52- Selecting Coordinate System in Utility Mode Robot Utility Work Tool Where Signal Memory -3-55- Selecting Coordinate System Using Robot Language Timing of Changing Coordinate System