The operator should set items such as the robot configuration and the communication channel modes before he or she operates the robot system. The operator should set the date and time for the controller for file management and fault display information. The operation for setting such data is called controller environmental condition setting. Except for the date and time, such data is stored in a system configuration file (CONSTRUC. SYS).

In addition, to use external signals to select a file to be executed, it is necessary to first create an external selection file (EXTRNSEL. SYS).

This chapter describes how to set individual data which defines the environmental conditions of the controller.

3.1SETTING DATE AND TIME

The controller provides a clock function which indicates the current date and time. When the robot system detects an error, the function indicates the date and time when the error occurred along with a related error message.

Date and time have been set at factory. However, when the controller power has been turned off for a long time, the controller clock may become off. In this case, it is necessary to reset the correct date and time.

Note)

The accuracy of the controller clock is within 15 sec per month. Thus, it is necessary to periodically check and adjust the clock.

3.1.1Setting Date

Set the current date in the following manner.

(1)Turn on the controller main power and place the MASTER MODE KEY switch on the control panel in the "MANU" position. The following monitor command menu will appear at the bottom on the teach pendant LCD display.

3-1

Image 60
Contents Industrial Robot SR Series START-UP Manual - i - Preface For Euporean Union EU - iv - Table of Contents Changing File DATA・・・・・・・・・・・・・・・・・・・・ Backing UP FILES・・・・・・・・・・・・・・・・・・・・・ Chapter Before Operating SR Series Robot Overview- 1-2 - - 1-3 - - 1-4 - PTP - 1-6 - - 1-7 - - 1-8 - Outline of Operational Procedure -1-10- Specifications -1-12- -1-13- Coordinate System -1-15- System Configuration -1-17- -1-18- -1-19- STE -1-20- Names and Functions of SR7000 Controller Control PanelPower LED Fault LEDTeach Pendant -1-24- -1-25- -1-26- STE -1-27- -1-28- Chapter Power on to Manual Guidance Turning on Main Power Cold Starting- 2-3 - Edit Load Save Testrun Reset Next Hot Starting - 2-6 - - 2-7 - Setting Controller Environmental Conditions Turning the Servo Power on Manual Guidance of Each Axis -2-11- -2-12- Manual Guidance Operation -2-14- -2-15- Setting Joint Limit Values by Teaching Motion Range LimitFormat Verify Zerop Jlimit Channel Next Next Jlimit Travel Joint Negative PositiveSetting Joint Limit by Numeric Value Entry Channel Next-2-19- Travel Joint Negative Positive Turning OFF the Power Turning OFF Servo PowerTurning OFF the Main Power -2-22- -2-23- Setting Date and Time Setting DateDate Date Time Next Setting Time Date Time NextTime Date Time Next - 3-5 - Changing File Data Edit CONSTRUC.SYS Edit Load Save Testrun Reset Next - 3-8 - - 3-9 - -3-10- -3-11- Setting the System Configuration Outline of Data-3-13- Specify for Gravity Compensation Servo Free Mode File FormatConstruction of MANIPULATER. =0WITHOUT,=1WITH Type of JOINT=0LINEAR.=1ROTATE, 1ST Joint to 5THSpecify for External File Selection Signal Mode of Serial ChannelMode of Channel COM1 Mode of Channel COM2Mode of AIR Driven Axis Specify for USE or not USE -3-17- Details of Data -3-19- -3-20- -3-21- PRT Host=HOST -3-24- -3-25- Setting External Selection Files Signals Used for Selecting FileContents of File -3-28- Batch Processing Batch File-3-30- Automatic Execution File LOADPRO1 LOADPRO2 LOADPRO3 LOADPRO4 Loadpros LOADPRO6Using Batch Processing Effectively Select PRO1Loadconstruc .SYS LOADSYSTEM. PAR LOADUSER. PAR LOAD*. PRO -3-33- Program Execution Environment Program Execution Environment-3-35- Resetting Execution Environment Reset Timing of Program Execution Environment Setting Coordinate System Robot Coordinate Systems-3-39- Teaching Coordinate Data System and the original coordinate system unit deg-3-41- Program Sample Move P1 Move P2 END -3-43- -3-44- -3-45- Selecting Coordinate System in Data Editor Mode -3-47- Z,C,T RightyLefty -3-49- -3-50- -3-51- -3-52- Selecting Coordinate System in Utility Mode Robot Utility Work Tool Where Signal Memory -3-55- Selecting Coordinate System Using Robot Language Timing of Changing Coordinate System