Toshiba STE 58760 instruction manual Manual Guidance of Each Axis

Page 46

STE 58760

2.4MANUAL GUIDANCE OF EACH AXIS

The operation where the robot is operated using the teach pendant is called manual guidance. When the servo power is turned on, conduct manual guidance for each axis and check to see that the robot works correctly. When actually operating the robot, make absolutely sure that the robot will not hit anybody or anything.

Conduct manual guidance in the following manner.

Caution

If the guidance is performed manually, DO NOT enter the robot dangerous area.

If the robot moves abnormally, immediately effect an emergency stop.

If the robot will not move in the specified direction, consult Toshiba Machine.

(1) Select the joint coordinate mode as the coordinates.

Press the "Coordinate" key on the teach pendant several times until the "Joint" LED lights up.

(2) Set the guide speed to low.

Press the "Teach Speed" key on the teach pendant several times until the "Low" LED lights up.

2-10

Image 46
Contents Industrial Robot SR Series START-UP Manual - i - Preface For Euporean Union EU - iv - Table of Contents Changing File DATA・・・・・・・・・・・・・・・・・・・・ Backing UP FILES・・・・・・・・・・・・・・・・・・・・・ Chapter Before Operating SR Series Robot Overview- 1-2 - - 1-3 - - 1-4 - PTP - 1-6 - - 1-7 - - 1-8 - Outline of Operational Procedure -1-10- Specifications -1-12- -1-13- Coordinate System -1-15- System Configuration -1-17- -1-18- -1-19- STE -1-20- Names and Functions of SR7000 Controller Control PanelPower LED Fault LEDTeach Pendant -1-24- -1-25- -1-26- STE -1-27- -1-28- Chapter Power on to Manual Guidance Turning on Main Power Cold Starting- 2-3 - Edit Load Save Testrun Reset Next Hot Starting - 2-6 - - 2-7 - Setting Controller Environmental Conditions Turning the Servo Power on Manual Guidance of Each Axis -2-11- -2-12- Manual Guidance Operation -2-14- -2-15- Motion Range Limit Setting Joint Limit Values by TeachingFormat Verify Zerop Jlimit Channel Next Next Jlimit Travel Joint Negative PositiveSetting Joint Limit by Numeric Value Entry Channel Next-2-19- Travel Joint Negative Positive Turning OFF Servo Power Turning OFF the PowerTurning OFF the Main Power -2-22- -2-23- Setting Date and Time Setting DateDate Date Time Next Setting Time Date Time NextTime Date Time Next - 3-5 - Changing File Data Edit CONSTRUC.SYS Edit Load Save Testrun Reset Next - 3-8 - - 3-9 - -3-10- -3-11- Setting the System Configuration Outline of Data-3-13- Construction of MANIPULATER. =0WITHOUT,=1WITH Specify for Gravity Compensation Servo Free ModeFile Format Type of JOINT=0LINEAR.=1ROTATE, 1ST Joint to 5THMode of Channel COM1 Specify for External File Selection SignalMode of Serial Channel Mode of Channel COM2Mode of AIR Driven Axis Specify for USE or not USE -3-17- Details of Data -3-19- -3-20- -3-21- PRT Host=HOST -3-24- -3-25- Setting External Selection Files Signals Used for Selecting FileContents of File -3-28- Batch Processing Batch File-3-30- Automatic Execution File LOADPRO1 LOADPRO2 LOADPRO3 LOADPRO4 Loadpros LOADPRO6Select PRO1 Using Batch Processing EffectivelyLoadconstruc .SYS LOADSYSTEM. PAR LOADUSER. PAR LOAD*. PRO -3-33- Program Execution Environment Program Execution Environment-3-35- Resetting Execution Environment Reset Timing of Program Execution Environment Setting Coordinate System Robot Coordinate Systems-3-39- Teaching Coordinate Data System and the original coordinate system unit deg-3-41- Program Sample Move P1 Move P2 END -3-43- -3-44- -3-45- Selecting Coordinate System in Data Editor Mode -3-47- Righty Z,C,TLefty -3-49- -3-50- -3-51- -3-52- Selecting Coordinate System in Utility Mode Robot Utility Work Tool Where Signal Memory -3-55- Selecting Coordinate System Using Robot Language Timing of Changing Coordinate System