Toshiba STE 58760 instruction manual - 2-6 -

Page 42

STE 58760

Note 1)

Should the "POWER LED" on the control panel not light even if the MAIN POWER switch is turned on, or should any fault occur in the system, immediately turn off the Main Power switch and check the cables connected to the controller.

Note 2)

If the system disk was in the FDD unit when the main power was turned on, the controller will perform cold start. Before turning on the main power, check to see that the system disk has not been inserted into the FDD unit.

Note 3)

If a floppy disk which contains any of the files CONSTRUC. SYS, SYSTEM. PAR, USER. PAR, EXTRNSEL. SYS, SCOL. LIB, ALARM.MES, or AUTOSTR. BAT has been inserted into the FDD unit, the contents of the files will be read to the controller when the main power is turned on. For an outline of each file, see Chapter 5.

(2) The controller starts up.

When the controller has been correctly started up, the following message appears on the LCD display on the teach pendant

>

EDIT LOAD SAVE TESTRUN> RESET NEXT

F1

F2

F3

F4

F5

F6

2-6

Image 42
Contents Industrial Robot SR Series START-UP Manual - i - Preface For Euporean Union EU - iv - Table of Contents Changing File DATA・・・・・・・・・・・・・・・・・・・・ Backing UP FILES・・・・・・・・・・・・・・・・・・・・・ Chapter Before Operating SR Series Robot Overview- 1-2 - - 1-3 - - 1-4 - PTP - 1-6 - - 1-7 - - 1-8 - Outline of Operational Procedure -1-10- Specifications -1-12- -1-13- Coordinate System -1-15- System Configuration -1-17- -1-18- -1-19- STE -1-20- Names and Functions of SR7000 Controller Control PanelPower LED Fault LEDTeach Pendant -1-24- -1-25- -1-26- STE -1-27- -1-28- Chapter Power on to Manual Guidance Turning on Main Power Cold Starting- 2-3 - Edit Load Save Testrun Reset Next Hot Starting - 2-6 - - 2-7 - Setting Controller Environmental Conditions Turning the Servo Power on Manual Guidance of Each Axis -2-11- -2-12- Manual Guidance Operation -2-14- -2-15- Setting Joint Limit Values by Teaching Motion Range LimitFormat Verify Zerop Jlimit Channel Next Next Jlimit Travel Joint Negative PositiveSetting Joint Limit by Numeric Value Entry Channel Next-2-19- Travel Joint Negative Positive Turning OFF the Power Turning OFF Servo PowerTurning OFF the Main Power -2-22- -2-23- Setting Date and Time Setting DateDate Date Time Next Setting Time Date Time NextTime Date Time Next - 3-5 - Changing File Data Edit CONSTRUC.SYS Edit Load Save Testrun Reset Next - 3-8 - - 3-9 - -3-10- -3-11- Setting the System Configuration Outline of Data-3-13- Construction of MANIPULATER. =0WITHOUT,=1WITH Specify for Gravity Compensation Servo Free ModeFile Format Type of JOINT=0LINEAR.=1ROTATE, 1ST Joint to 5THMode of Channel COM1 Specify for External File Selection SignalMode of Serial Channel Mode of Channel COM2Mode of AIR Driven Axis Specify for USE or not USE -3-17- Details of Data -3-19- -3-20- -3-21- PRT Host=HOST -3-24- -3-25- Setting External Selection Files Signals Used for Selecting FileContents of File -3-28- Batch Processing Batch File-3-30- Automatic Execution File LOADPRO1 LOADPRO2 LOADPRO3 LOADPRO4 Loadpros LOADPRO6Using Batch Processing Effectively Select PRO1Loadconstruc .SYS LOADSYSTEM. PAR LOADUSER. PAR LOAD*. PRO -3-33- Program Execution Environment Program Execution Environment-3-35- Resetting Execution Environment Reset Timing of Program Execution Environment Setting Coordinate System Robot Coordinate Systems-3-39- Teaching Coordinate Data System and the original coordinate system unit deg-3-41- Program Sample Move P1 Move P2 END -3-43- -3-44- -3-45- Selecting Coordinate System in Data Editor Mode -3-47- Z,C,T RightyLefty -3-49- -3-50- -3-51- -3-52- Selecting Coordinate System in Utility Mode Robot Utility Work Tool Where Signal Memory -3-55- Selecting Coordinate System Using Robot Language Timing of Changing Coordinate System