Toshiba STE 58760 instruction manual Chapter Power on to Manual Guidance

Page 37

STE 58760

CHAPTER 2

POWER ON TO MANUAL GUIDANCE

This chapter outlines how to turn on the power and how to manually guide the robot. For details of how to create a robot language program, how to teach positions to the robot, and how to perform an automatic operation, see Chapter 4, "Example of Simple Operation". Before actually operating the robot, it is necessary to check that the cables have been correctly connected. For details of how to install the robot, see the Transportation and Installation Manual.

The operation procedure from the power ON operation to manual guidance operation is as follows:

(1)Turn on the main power of the controller.

(2)Set the environmental conditions of the controller.

(3)Turn on the servo power.

(4)Manually guide each axis and check that the robot works correctly.

(5)Perform the manual guidance operation and check the robot operation.

(6)Set the operation range.

(7)Turn off the power supply.

Note)

When performing operations described in this chapter, be sure to place the MASTER MODE KEY switch in the "MANU" (manual mode) position.

2-1

Image 37
Contents Industrial Robot SR Series START-UP Manual - i - Preface For Euporean Union EU - iv - Table of Contents Changing File DATA・・・・・・・・・・・・・・・・・・・・ Backing UP FILES・・・・・・・・・・・・・・・・・・・・・ Overview Chapter Before Operating SR Series Robot- 1-2 - - 1-3 - - 1-4 - PTP - 1-6 - - 1-7 - - 1-8 - Outline of Operational Procedure -1-10- Specifications -1-12- -1-13- Coordinate System -1-15- System Configuration -1-17- -1-18- -1-19- STE -1-20- Control Panel Names and Functions of SR7000 ControllerFault LED Power LEDTeach Pendant -1-24- -1-25- -1-26- STE -1-27- -1-28- Chapter Power on to Manual Guidance Cold Starting Turning on Main Power- 2-3 - Edit Load Save Testrun Reset Next Hot Starting - 2-6 - - 2-7 - Setting Controller Environmental Conditions Turning the Servo Power on Manual Guidance of Each Axis -2-11- -2-12- Manual Guidance Operation -2-14- -2-15- Motion Range Limit Setting Joint Limit Values by TeachingFormat Verify Zerop Jlimit Channel Next Jlimit Travel Joint Negative Positive NextChannel Next Setting Joint Limit by Numeric Value Entry-2-19- Travel Joint Negative Positive Turning OFF Servo Power Turning OFF the PowerTurning OFF the Main Power -2-22- -2-23- Setting Date Setting Date and TimeDate Date Time Next Date Time Next Setting TimeTime Date Time Next - 3-5 - Changing File Data Edit CONSTRUC.SYS Edit Load Save Testrun Reset Next - 3-8 - - 3-9 - -3-10- -3-11- Outline of Data Setting the System Configuration-3-13- File Format Specify for Gravity Compensation Servo Free ModeConstruction of MANIPULATER. =0WITHOUT,=1WITH Type of JOINT=0LINEAR.=1ROTATE, 1ST Joint to 5THMode of Serial Channel Specify for External File Selection SignalMode of Channel COM1 Mode of Channel COM2Mode of AIR Driven Axis Specify for USE or not USE -3-17- Details of Data -3-19- -3-20- -3-21- Host PRT=HOST -3-24- -3-25- Signals Used for Selecting File Setting External Selection FilesContents of File -3-28- Batch File Batch Processing-3-30- LOADPRO1 LOADPRO2 LOADPRO3 LOADPRO4 Loadpros LOADPRO6 Automatic Execution FileSelect PRO1 Using Batch Processing EffectivelyLoadconstruc .SYS LOADSYSTEM. PAR LOADUSER. PAR LOAD*. PRO -3-33- Program Execution Environment Program Execution Environment-3-35- Resetting Execution Environment Reset Timing of Program Execution Environment Robot Coordinate Systems Setting Coordinate System-3-39- System and the original coordinate system unit deg Teaching Coordinate Data-3-41- Program Sample Move P1 Move P2 END -3-43- -3-44- -3-45- Selecting Coordinate System in Data Editor Mode -3-47- Righty Z,C,TLefty -3-49- -3-50- -3-51- -3-52- Selecting Coordinate System in Utility Mode Robot Utility Work Tool Where Signal Memory -3-55- Timing of Changing Coordinate System Selecting Coordinate System Using Robot Language