Toshiba STE 58760 instruction manual -3-13-

Page 72

STE 58760

(5)Motor revolving direction

Specifies the basic direction in which the motor revolves (i.e., CW or CCW). SR–7000 can use only axis 1 to axis 4, and specify zero for axis 5 and axis 6.

(6)Not used (spare)

(7)Not used (spare)

(8)Not used (spare)

(9)Control method for external automatic mode

Specifies whether the system is to be controlled using I/O signals or data communication from a host computer.

(10)Not used (spare)

(11)File selection signal line

Specifies an external input signal to be used to select a file which is to be externally executed.

(12)Speed in low speed instruction mode

Sets a speed at which the robot works when a low speed instruction signal is input.

(13)Communication mode

Sets a communication channel mode used for data communication.

(14)Auxiliary signal line

Sets auxiliary signals used for hand and air control axes of the robot.

(15) Storage

Sets the use of a floppy disk unit or a substitute personal computer.

(16)Not used (spare)

3-13

Image 72
Contents Industrial Robot SR Series START-UP Manual - i - Preface For Euporean Union EU - iv - Table of Contents Changing File DATA・・・・・・・・・・・・・・・・・・・・ Backing UP FILES・・・・・・・・・・・・・・・・・・・・・ Chapter Before Operating SR Series Robot Overview- 1-2 - - 1-3 - - 1-4 - PTP - 1-6 - - 1-7 - - 1-8 - Outline of Operational Procedure -1-10- Specifications -1-12- -1-13- Coordinate System -1-15- System Configuration -1-17- -1-18- -1-19- STE -1-20- Names and Functions of SR7000 Controller Control PanelPower LED Fault LEDTeach Pendant -1-24- -1-25- -1-26- STE -1-27- -1-28- Chapter Power on to Manual Guidance Turning on Main Power Cold Starting- 2-3 - Edit Load Save Testrun Reset Next Hot Starting - 2-6 - - 2-7 - Setting Controller Environmental Conditions Turning the Servo Power on Manual Guidance of Each Axis -2-11- -2-12- Manual Guidance Operation -2-14- -2-15- Setting Joint Limit Values by Teaching Motion Range LimitFormat Verify Zerop Jlimit Channel Next Next Jlimit Travel Joint Negative PositiveSetting Joint Limit by Numeric Value Entry Channel Next-2-19- Travel Joint Negative Positive Turning OFF the Power Turning OFF Servo PowerTurning OFF the Main Power -2-22- -2-23- Setting Date and Time Setting DateDate Date Time Next Setting Time Date Time NextTime Date Time Next - 3-5 - Changing File Data Edit CONSTRUC.SYS Edit Load Save Testrun Reset Next - 3-8 - - 3-9 - -3-10- -3-11- Setting the System Configuration Outline of Data-3-13- Specify for Gravity Compensation Servo Free Mode File FormatConstruction of MANIPULATER. =0WITHOUT,=1WITH Type of JOINT=0LINEAR.=1ROTATE, 1ST Joint to 5THSpecify for External File Selection Signal Mode of Serial ChannelMode of Channel COM1 Mode of Channel COM2Mode of AIR Driven Axis Specify for USE or not USE -3-17- Details of Data -3-19- -3-20- -3-21- PRT Host=HOST -3-24- -3-25- Setting External Selection Files Signals Used for Selecting FileContents of File -3-28- Batch Processing Batch File-3-30- Automatic Execution File LOADPRO1 LOADPRO2 LOADPRO3 LOADPRO4 Loadpros LOADPRO6Using Batch Processing Effectively Select PRO1Loadconstruc .SYS LOADSYSTEM. PAR LOADUSER. PAR LOAD*. PRO -3-33- Program Execution Environment Program Execution Environment-3-35- Resetting Execution Environment Reset Timing of Program Execution Environment Setting Coordinate System Robot Coordinate Systems-3-39- Teaching Coordinate Data System and the original coordinate system unit deg-3-41- Program Sample Move P1 Move P2 END -3-43- -3-44- -3-45- Selecting Coordinate System in Data Editor Mode -3-47- Z,C,T RightyLefty -3-49- -3-50- -3-51- -3-52- Selecting Coordinate System in Utility Mode Robot Utility Work Tool Where Signal Memory -3-55- Selecting Coordinate System Using Robot Language Timing of Changing Coordinate System