Hitachi hitachi series inverter D006, D007, D008, D009, D010, D012, D013, D014, D015, D016, D017

Page 49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Run

 

 

Units

 

 

Func.

 

 

Name

 

 

 

Description

 

 

 

Mode

 

 

 

 

Code

 

 

 

 

 

 

 

 

Edit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D006

 

Intelligent output

 

 

Displays the state of the intelligent

 

 

 

 

 

 

 

 

 

terminal status

 

 

output terminals:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay

12 11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D007

 

Scaled output frequency

 

 

Displays the output frequency scaled

 

 

 

 

Hz times

 

 

 

 

monitor

 

 

by the constant in B086.

 

 

 

 

 

 

 

constant

 

 

 

 

 

 

 

Decimal point indicates range:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 3999

 

 

 

 

 

 

 

 

 

 

d008

 

Actual frequency monitor

 

 

Displays the actual frequency, range

 

 

 

 

 

Hz

 

 

 

 

 

 

 

is -400 to 400 Hz

 

 

 

 

 

 

 

 

 

 

d009

 

Torque command monitor

 

 

Displays the torque command, range

 

 

 

 

%

 

 

 

 

 

 

 

 

is -200 to 200 %

 

 

 

 

 

 

 

 

 

 

d010

 

Torque bias monitor

 

 

Displays the torque bias value, range

 

 

 

 

%

 

 

 

 

 

 

 

 

is -200 to 200 %

 

 

 

 

 

 

 

 

 

 

d012

 

Output torque monitor

 

 

Displays the output torque, range is

 

 

 

 

%

 

 

 

 

 

 

 

 

-200 to 200 %

 

 

 

 

 

 

 

 

 

 

D013

 

Output voltage monitor

 

 

Voltage of output to motor,

 

 

 

 

 

V

 

 

 

 

 

 

 

Range is 0.0 to 600.0V

 

 

 

 

 

 

 

 

 

 

d014

 

Input power monitor

 

 

Displays the input power, range is 0

 

 

 

 

 

KW

 

 

 

 

 

 

 

to 999.9 kW

 

 

 

 

 

 

 

 

 

 

d015

 

Watt-hour monitor

 

 

Displays watt-hour of the inverter,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

range is 0 to 9999000

 

 

 

 

 

 

 

 

 

 

D016

 

Elapsed RUN time monitor

 

 

Displays total time the inverter has

 

 

 

 

 

hours

 

 

 

 

 

 

 

been in RUN mode in hours.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range is 0 to 9999 / 1000 to 9999 /

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 to 999 (10,000 to 99,900)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D017

 

Elapsed power-on time

 

 

Displays total time the inverter has

 

 

 

 

 

hours

 

 

 

 

monitor

 

 

been powered up in hours.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range is 0 to 9999 / 1000 to 9999 /

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 to 999 (10,000 to 99,900)

 

 

 

 

 

 

 

 

D018

 

Heat sink temperature monitor

 

 

Temperature of the cooling fin, range

 

 

 

 

 

°C

 

 

 

 

 

 

 

is -20~150

 

 

 

 

 

 

 

 

 

 

d022

 

Life check monitor

 

 

Displays the state of lifetime of

 

 

 

 

 

 

 

 

 

 

 

 

electrolytic capacitors on the PWB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and cooling fan.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lifetime expired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling fan

Electrolytic caps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d023

 

Program counter monitor

 

 

Range is 0 to 1024

 

 

 

 

 

 

 

 

 

 

 

[EzSQ]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d024

 

Program number monitor

 

 

Range is 0 to 9999

 

 

 

 

 

 

 

 

 

 

 

[EzSQ]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d025

 

User monitor 0

 

 

Result of EzSQ execution, range is

 

 

 

 

 

 

 

 

 

[EzSQ]

 

 

–2147483647~2147483647

 

 

 

 

 

 

 

 

d026

 

User monitor 1

 

 

Result of EzSQ execution, range is

 

 

 

 

 

 

 

 

 

[EzSQ]

 

 

–2147483647~2147483647

 

 

 

 

 

 

 

 

d027

 

User monitor 2

 

 

Result of EzSQ execution, range is

 

 

 

 

 

 

 

 

 

[EzSQ]

 

 

–2147483647~2147483647

 

 

 

 

 

 

 

 

47

Image 49
Contents WJ200 Series Inverter Quick Reference Guide Page UL→ Cautions, Warnings and Instructions Marking RequirementsTerminal symbols and Screw size Fuse Sizes 5AT 123 45A-001 1005 Inverter Specification LabelModel-specific tables for 200V and 400V class inverters WJ200 Inverter SpecificationsWJ200 Inverter Specifications, … WJ200 inverters, 400V models Derating GFI Basic System DescriptionInverter + Motor Output Determining Wire and Fuse SizesAllowable current T1 V/T2 W/T3 L1 S/L2 T/L3 U/T1 V/T2 W/T3 Wire the Inverter Input to a SupplyRB PD/+1 P/+ Three-phase 200V 11kW Three-phase 400V 11, 15kW Key and Indicator Legend Using the Front Panel KeypadPower LED Alarm LED Keypad Navigation Map Keys, Modes, and ParametersPRG LED Group F Group dSave Group aF001 Key GND Connecting to PLCs and Other DevicesMotor Example Wiring DiagramPulse Control Logic Signal SpecificationsTrain Output InputSP, SN Wiring sample of control logic terminal sink logicSink/source logic of intelligent input terminals Wire size for control and relay terminalsRecommended ferrule Intelligent Inputs Intelligent Terminal ListingIntelligent Outputs Sink logic connection Using Intelligent Input TerminalsSource logic connection WJ200 Sinking Inputs, Internal SupplySourcing Inputs, Internal Supply Sourcing Inputs, External Supply Sinking Inputs, External SupplyOFF InsertingOption Terminal Code Symbol Function Name State Description Forward Run/Stop and Reverse Run/Stop CommandsMulti-Speed Select ~Binary Operation Required settingsFW,RV Two Stage Acceleration and Deceleration2CH Unattended Start Protection Option Terminal Function Name State Description Code SymbolUSP Reset Inverter Run Signal Using Intelligent Output TerminalsCode Symbol Option Terminal Function NameSettings Frequency Arrival SignalsRequired FA3/FA5 FA2/FA4Stop Alarm SignalTrip During normal operation AM H O OI L Analog Input OperationAM H O OI Other Analog Input-related topics SN 7 6 5 4 3 2 1 L PLC P24 Pulse Train Input OperationAnalog Output Operation AM signal offset and gain are adjustable, as indicated below Monitoring functions D007 D006D008 D009D030 D029D050 D060Main Profile Parameters Standard Functions A220 A015A241 A021 ~ A035A043 A242A243 A044A059 A058A061 A261A073 A072A074 A075A292 A092A093 A293A132 A131A141 A142A157 A156A161 A162Fine Tuning Functions B212 B012B013 B213B026 B025B027 B028B038 B037B039 B040B061 B060B062 B063B088 B087B089 B090B097 B096B100 B101B134 B133B145 B150Intelligent Terminal Functions C030 C028C031 C032C052 C047C053 C054C077 C076C078 C081C103 C102C104 C105C148 C147C149 C150FWD, REV AnlgPidc DWNSF2 SF1SF3 SF4255 Run Signal When the inverter is in Run Mode LOG2 LOG1LOG3 MO1 C039MO2 MO3Motor Constants Functions PM Motor Constants Functions H113 H112H116 H117Expansion Card Functions P044 P041P045 P046P073 P072P075 P077Trip History and Inverter Status Monitoring Trip Events, History, & ConditionsError Name Causes Code Error CodesE37 Error Name Descriptions Code Restoring Factory Default SettingsOther indication Important notes CE-EMC Installation GuidelinesPage Page Metal plate earth Installation for WJ200 series example of SF modelsHitachi EMC Recommendations Introduction Functional Safety Certification in ProgressStop Category defined in EN60204-1 How it worksInstallation Wiring example OFF G9SX GS9ANE1A