Hitachi hitachi series inverter user manual Standard Functions

Page 52

Standard Functions

NOTE:. Mark “ ” in b031=10 shows the accessible parameters when b031 is set “10”, high level access.

 

 

 

 

 

 

 

 

Func.

 

Name

 

Description

 

 

Code

 

 

 

 

 

 

 

 

 

Run

Mode

Edit

Initialdata Units

A001

Frequency source

Eight options; select codes:

 

 

02

 

 

00

POT on ext. operator

 

 

 

 

 

 

01

Control terminal

 

 

 

 

A201

Frequency source,

02

Function F001 setting

 

 

02

2nd motor

03

Modbus network input

 

 

 

 

 

 

04

Option

 

 

 

 

 

 

06

Pulse train input

 

 

 

 

 

 

07

via EzSQ

 

 

 

 

 

 

10

Calculate function output

 

 

 

 

A002

Run command source

Four options; select codes:

 

 

02

 

 

01

Control terminal

 

 

 

 

 

Run command source,

02

Run key on keypad, or

 

 

 

 

A202

 

digital operator

 

 

02

2nd motor

03

Modbus network input

 

 

 

 

 

 

04

Option

 

 

 

 

A003

Base frequency

Settable from 30 Hz to the

 

 

60.0

Hz

 

 

maximum frequency(A004)

 

 

 

 

A203

Base frequency,

Settable from 30 Hz to the 2nd

 

 

 

Hz

 

 

60.0

2nd motor

maximum frequency(A204)

 

 

 

 

 

 

 

 

 

A004

Maximum frequency

Settable from the base

 

60.0

Hz

 

 

frequency to 400 Hz

 

 

 

A204

Maximum frequency,

Settable from the 2nd base

 

 

Hz

60.0

2nd motor

frequency to 400 Hz

 

 

 

 

 

 

 

 

 

A005

[AT] selection

Three options; select codes:

 

00

 

 

00...Select between [O] and [OI]

 

 

 

 

 

 

at [AT] (ON=OI, OFF=O)

 

 

 

 

 

02...Select between [O] and

 

 

 

 

 

 

external POT at [AT]

 

 

 

 

 

 

(ON=POT, OFF=O)

 

 

 

 

 

03...Select between [OI] and

 

 

 

 

 

 

external POT at [AT]

 

 

 

 

 

 

(ON=POT, OFF=OI)

 

 

 

A011

[O] input active range start

The output frequency

 

0.00

Hz

frequency

corresponding to the analog

 

 

 

 

 

input range starting point,

 

 

 

 

 

range is 0.00 to 400.0

 

 

 

A012

[O] input active range end

The output frequency

 

0.00

Hz

frequency

corresponding to the analog

 

 

 

 

 

input range ending point,

 

 

 

 

 

range is 0.0 to 400.0

 

 

 

A013

[O] input active range start

The starting point (offset) for the

 

0.

%

voltage

active analog input range,

 

 

 

 

 

range is 0. to 100.

 

 

 

A014

[O] input active range end

The ending point (offset) for the

 

100.

%

voltage

active analog input range,

 

 

 

 

 

range is 0. to 100.

 

 

 

50

Image 52
Contents WJ200 Series Inverter Quick Reference Guide Page Marking Requirements UL→ Cautions, Warnings and InstructionsTerminal symbols and Screw size Fuse Sizes Inverter Specification Label 5AT 123 45A-001 1005WJ200 Inverter Specifications Model-specific tables for 200V and 400V class invertersWJ200 Inverter Specifications, … WJ200 inverters, 400V models Derating GFI Basic System DescriptionInverter + Motor Output Determining Wire and Fuse SizesAllowable current Wire the Inverter Input to a Supply T1 V/T2 W/T3 L1 S/L2 T/L3 U/T1 V/T2 W/T3RB PD/+1 P/+ Three-phase 200V 11kW Three-phase 400V 11, 15kW Key and Indicator Legend Using the Front Panel KeypadPower LED Alarm LED Keypad Navigation Map Keys, Modes, and ParametersPRG LED Group d Group FSave Group aF001 Key Connecting to PLCs and Other Devices GNDExample Wiring Diagram MotorControl Logic Signal Specifications PulseTrain Output InputWiring sample of control logic terminal sink logic SP, SNWire size for control and relay terminals Sink/source logic of intelligent input terminalsRecommended ferrule Intelligent Terminal Listing Intelligent InputsIntelligent Outputs Sink logic connection Using Intelligent Input TerminalsSource logic connection WJ200 Sinking Inputs, Internal SupplySourcing Inputs, Internal Supply Sinking Inputs, External Supply Sourcing Inputs, External SupplyInserting OFFForward Run/Stop and Reverse Run/Stop Commands Option Terminal Code Symbol Function Name State DescriptionRequired settings Multi-Speed Select ~Binary OperationFW,RV Two Stage Acceleration and Deceleration2CH Unattended Start Protection Option Terminal Function Name State Description Code SymbolUSP Reset Inverter Using Intelligent Output Terminals Run SignalCode Symbol Option Terminal Function NameSettings Frequency Arrival SignalsRequired FA2/FA4 FA3/FA5Stop Alarm SignalTrip During normal operation AM H O OI L Analog Input OperationAM H O OI Other Analog Input-related topics Pulse Train Input Operation SN 7 6 5 4 3 2 1 L PLC P24Analog Output Operation AM signal offset and gain are adjustable, as indicated below Monitoring functions D006 D007D008 D009D029 D030D050 D060Main Profile Parameters Standard Functions A015 A220A241 A021 ~ A035A242 A043A243 A044A058 A059A061 A261A072 A073A074 A075A092 A292A093 A293A131 A132A141 A142A156 A157A161 A162Fine Tuning Functions B012 B212B013 B213B025 B026B027 B028B037 B038B039 B040B060 B061B062 B063B087 B088B089 B090B096 B097B100 B101B133 B134B145 B150Intelligent Terminal Functions C028 C030C031 C032C047 C052C053 C054C076 C077C078 C081C102 C103C104 C105C147 C148C149 C150Anlg FWD, REVPidc DWNSF1 SF2SF3 SF4255 Run Signal When the inverter is in Run Mode LOG2 LOG1LOG3 C039 MO1MO2 MO3Motor Constants Functions PM Motor Constants Functions H112 H113H116 H117Expansion Card Functions P041 P044P045 P046P072 P073P075 P077Monitoring Trip Events, History, & Conditions Trip History and Inverter StatusError Codes Error Name Causes CodeE37 Error Name Descriptions Code Restoring Factory Default SettingsOther indication CE-EMC Installation Guidelines Important notesPage Page Installation for WJ200 series example of SF models Metal plate earthHitachi EMC Recommendations Functional Safety Certification in Progress IntroductionStop Category defined in EN60204-1 How it worksInstallation Wiring example OFF G9SX GS9ANE1A