Hitachi hitachi series inverter user manual Using the Front Panel Keypad, Key and Indicator Legend

Page 16

Using the Front Panel Keypad

Please take a moment to familiarize yourself with the keypad layout shown in the figure below. The display is used in programming the inverter’s parameters, as well as monitoring specific parameter values during operation.

(4) RUN LED

(5) Monitor LED [Hz]

(6) Monitor LED [A]

(8) 7-seg LED

(7)Run command LED

(9)RUN key

(11)ESC key

8888

RUN

 

1

 

STOP

 

 

RESET

 

 

 

 

 

 

 

 

 

ESC

 

2

 

SET

 

 

 

 

 

RUN PWR

Hz ALM

A PRG

(1)POWER LED

(2)ALARM LED

(3)Program LED

(15)USB connector

(10)STOP/RESET key

(16)RJ45 connector

 

 

 

 

(12) Up key

(13) Down key

(14) SET key

 

Key and Indicator Legend

 

 

 

 

 

 

 

 

 

(1)

POWER LED

 

 

Turns ON (Green) while the inverter is powered up.

 

(2) ALARM LED

 

 

Turns ON (Red) when the inverter trips.

 

 

(3)

Program LED

 

 

Turns ON (Green) when the display shows changeable parameter.

 

 

 

Blinks when there is a mismatch in setting.

 

 

 

 

 

 

(4)

RUN LED

 

 

Turns ON (Green) when the inverter is driving the motor.

 

(5)

Monitor LED [Hz]

 

Turns ON (Green) when the displayed data is frequency related.

 

(6)

Monitor LED [A]

 

 

Turns ON (Green) when the displayed data is current related.

 

(7)

Run command LED

 

Turns ON (Green) when a Run command is set to the operator. (Run key is effective.)

 

(8)

7-seg LED

 

 

Shows each parameter, monitors etc.

 

 

(9)

RUN key

 

Makes inverter run.

 

 

 

(10) STOP/RESET key

 

 

Makes inverter decelerates to a stop.

 

 

 

 

Reset the inverter when it is in trip situation

 

 

 

 

 

 

 

 

 

 

Go to the top of next function group, when a function mode is shown

 

(11) ESC key

 

 

Cancel the setting and return to the function code, when a data is shown

 

 

 

Moves the cursor to a digit left, when it is in digit-to-digit setting mode

 

 

 

 

 

 

 

 

 

 

Pressing for 1 second leads to display data of d001, regardless of current display.

 

(12) Up key

 

 

Increase or decrease the data.

 

 

(13) Down key

 

 

Pressing the both keys at the same time gives you the digit-to-digit edit.

 

 

 

 

 

Go to the data display mode when a function code is shown

 

(14) SET key

 

 

Stores the data and go back to show the function code, when data is shown.

 

 

 

 

 

Moves the cursor to a digit right, when it is in digit-to-digit display mode

 

(15) USB connector

 

 

Connect USB connector (mini-B) for using PC communication

 

(16) RJ45 connector

 

 

Connect RJ45 jack for remote operator

 

 

14

Image 16
Contents WJ200 Series Inverter Quick Reference Guide Page Marking Requirements UL→ Cautions, Warnings and InstructionsTerminal symbols and Screw size Fuse Sizes Inverter Specification Label 5AT 123 45A-001 1005WJ200 Inverter Specifications Model-specific tables for 200V and 400V class invertersWJ200 Inverter Specifications, … WJ200 inverters, 400V models Derating GFI Basic System DescriptionInverter + Motor Output Determining Wire and Fuse SizesAllowable current Wire the Inverter Input to a Supply T1 V/T2 W/T3 L1 S/L2 T/L3 U/T1 V/T2 W/T3RB PD/+1 P/+ Three-phase 200V 11kW Three-phase 400V 11, 15kW Key and Indicator Legend Using the Front Panel KeypadPower LED Alarm LED Keypad Navigation Map Keys, Modes, and ParametersPRG LED Group d Group FSave Group aF001 Key Connecting to PLCs and Other Devices GNDExample Wiring Diagram MotorControl Logic Signal Specifications PulseTrain Output InputWiring sample of control logic terminal sink logic SP, SNWire size for control and relay terminals Sink/source logic of intelligent input terminalsRecommended ferrule Intelligent Terminal Listing Intelligent InputsIntelligent Outputs Sink logic connection Using Intelligent Input TerminalsSource logic connection WJ200 Sinking Inputs, Internal SupplySourcing Inputs, Internal Supply Sinking Inputs, External Supply Sourcing Inputs, External SupplyInserting OFFForward Run/Stop and Reverse Run/Stop Commands Option Terminal Code Symbol Function Name State DescriptionRequired settings Multi-Speed Select ~Binary OperationFW,RV Two Stage Acceleration and Deceleration2CH Unattended Start Protection Option Terminal Function Name State Description Code SymbolUSP Reset Inverter Using Intelligent Output Terminals Run SignalCode Symbol Option Terminal Function NameSettings Frequency Arrival SignalsRequired FA2/FA4 FA3/FA5Stop Alarm SignalTrip During normal operation AM H O OI L Analog Input OperationAM H O OI Other Analog Input-related topics Pulse Train Input Operation SN 7 6 5 4 3 2 1 L PLC P24Analog Output Operation AM signal offset and gain are adjustable, as indicated below Monitoring functions D006 D007D008 D009D029 D030D050 D060Main Profile Parameters Standard Functions A015 A220A241 A021 ~ A035A242 A043A243 A044A058 A059A061 A261A072 A073A074 A075A092 A292A093 A293A131 A132A141 A142A156 A157A161 A162Fine Tuning Functions B012 B212B013 B213B025 B026B027 B028B037 B038B039 B040B060 B061B062 B063B087 B088B089 B090B096 B097B100 B101B133 B134B145 B150Intelligent Terminal Functions C028 C030C031 C032C047 C052C053 C054C076 C077C078 C081C102 C103C104 C105C147 C148C149 C150Anlg FWD, REVPidc DWNSF1 SF2SF3 SF4255 Run Signal When the inverter is in Run Mode LOG2 LOG1LOG3 C039 MO1MO2 MO3Motor Constants Functions PM Motor Constants Functions H112 H113H116 H117Expansion Card Functions P041 P044P045 P046P072 P073P075 P077Monitoring Trip Events, History, & Conditions Trip History and Inverter StatusError Codes Error Name Causes CodeE37 Error Name Descriptions Code Restoring Factory Default SettingsOther indication CE-EMC Installation Guidelines Important notesPage Page Installation for WJ200 series example of SF models Metal plate earthHitachi EMC Recommendations Functional Safety Certification in Progress IntroductionStop Category defined in EN60204-1 How it worksInstallation Wiring example OFF G9SX GS9ANE1A