Hitachi hitachi series inverter user manual 255

Page 76

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option

 

 

Terminal

 

 

Function Name

 

 

 

Description

 

 

Code

 

 

Symbol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

 

 

MI3

 

General purpose input

 

ON

General purpose input (3) is made ON under EzSQ

 

 

 

 

 

 

 

(3)

 

 

OFF

General purpose input (3) is made OFF under EzSQ

 

 

59

 

 

MI4

General purpose input

 

ON

General purpose input (4) is made ON under EzSQ

 

 

 

 

 

 

 

(4)

 

 

OFF

General purpose input (4) is made OFF under EzSQ

 

 

60

 

 

MI5

General purpose input

 

ON

General purpose input (5) is made ON under EzSQ

 

 

 

 

 

 

 

(5)

 

 

OFF

General purpose input (5) is made OFF under EzSQ

 

 

61

 

 

MI6

General purpose input

 

ON

General purpose input (6) is made ON under EzSQ

 

 

 

 

 

 

 

(6)

 

 

OFF

General purpose input (6) is made OFF under EzSQ

 

 

62

 

 

MI7

General purpose input

 

ON

General purpose input (7) is made ON under EzSQ

 

 

 

 

 

 

 

(7)

 

 

OFF

General purpose input (7) is made OFF under EzSQ

 

 

65

 

 

AHD

Analog command hold

 

ON

Analog command is held

 

 

 

 

 

 

 

 

 

 

 

OFF

Analog command is not held

 

 

66

 

 

CP1

 

Multistage-position

 

ON

Multistage position commands are set according to the

 

 

 

 

 

 

 

 

switch (1)

 

OFF

combination of these switches.

 

 

67

 

 

CP2

 

Multistage-position

 

ON

 

 

 

 

 

 

 

 

 

switch (2)

 

OFF

 

 

 

68

 

 

CP3

 

Multistage-position

 

ON

 

 

 

 

 

 

 

 

 

switch (3)

 

OFF

 

 

 

69

 

 

ORL

Limit signal of homing

 

ON

Limit signal of homing is ON

 

 

 

 

 

 

 

 

 

 

 

OFF

Limit signal of homing is OFF

 

 

70

 

 

ORG

Trigger signal of

 

ON

Starts homing operation

 

 

 

 

 

 

 

 

homing

 

OFF

No action

 

 

73

 

 

SPD

Speed/position

 

ON

Speed control mode

 

 

 

 

 

 

 

 

changeover

 

OFF

Position control mode

 

 

77

 

 

GS1

GS1 input

 

ON

EN60204-1 related signals:

 

 

 

 

 

 

 

 

 

 

 

OFF

Signal input of “Safe torque off” function.

 

 

78

 

 

GS2

GS2 input

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

81

 

485

 

 

Start EzCOM

 

ON

Starts EzCOM

 

 

 

 

 

 

 

 

 

 

 

OFF

No execution

 

 

82

 

 

PRG

Executing EzSQ

 

ON

Executing EzSQ program

 

 

 

 

 

 

 

 

program

 

OFF

No execution

 

 

83

 

 

HLD

 

Retain output

 

ON

Retain the current output frequency

 

 

 

 

 

 

 

 

frequency

 

OFF

No retention

 

 

84

 

 

ROK

Permission of Run

 

ON

Run command permitted

 

 

 

 

 

 

 

 

command

 

OFF

Run command is not permitted

 

 

85

 

 

EB

Rotation direction

 

ON

Forward rotation

 

 

 

 

 

 

 

 

detection (C007 only)

 

OFF

Reverse rotation

 

 

86

 

 

DISP

Display limitation

 

ON

Only a parameter configured in b038 is shown

 

 

 

 

 

 

 

 

 

 

 

OFF

All the monitors can be shown

 

 

255

 

 

no

 

No function

 

ON

(input ignored)

 

 

 

 

 

 

OFF

(input ignored)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

Image 76
Contents WJ200 Series Inverter Quick Reference Guide Page Marking Requirements UL→ Cautions, Warnings and InstructionsTerminal symbols and Screw size Fuse Sizes Inverter Specification Label 5AT 123 45A-001 1005WJ200 Inverter Specifications Model-specific tables for 200V and 400V class invertersWJ200 Inverter Specifications, … WJ200 inverters, 400V models Derating GFI Basic System DescriptionInverter + Motor Output Determining Wire and Fuse SizesAllowable current Wire the Inverter Input to a Supply T1 V/T2 W/T3 L1 S/L2 T/L3 U/T1 V/T2 W/T3RB PD/+1 P/+ Three-phase 200V 11kW Three-phase 400V 11, 15kW Key and Indicator Legend Using the Front Panel KeypadPower LED Alarm LED Keypad Navigation Map Keys, Modes, and ParametersPRG LED Group d Group FSave Group aF001 Key Connecting to PLCs and Other Devices GNDExample Wiring Diagram MotorControl Logic Signal Specifications PulseTrain Output InputWiring sample of control logic terminal sink logic SP, SNWire size for control and relay terminals Sink/source logic of intelligent input terminalsRecommended ferrule Intelligent Terminal Listing Intelligent InputsIntelligent Outputs Sink logic connection Using Intelligent Input TerminalsSource logic connection WJ200 Sinking Inputs, Internal SupplySourcing Inputs, Internal Supply Sinking Inputs, External Supply Sourcing Inputs, External SupplyInserting OFFForward Run/Stop and Reverse Run/Stop Commands Option Terminal Code Symbol Function Name State DescriptionRequired settings Multi-Speed Select ~Binary OperationFW,RV Two Stage Acceleration and Deceleration2CH Unattended Start Protection Option Terminal Function Name State Description Code SymbolUSP Reset Inverter Using Intelligent Output Terminals Run SignalCode Symbol Option Terminal Function NameSettings Frequency Arrival SignalsRequired FA2/FA4 FA3/FA5Stop Alarm SignalTrip During normal operation AM H O OI L Analog Input OperationAM H O OI Other Analog Input-related topics Pulse Train Input Operation SN 7 6 5 4 3 2 1 L PLC P24Analog Output Operation AM signal offset and gain are adjustable, as indicated below Monitoring functions D006 D007D008 D009D029 D030D050 D060Main Profile Parameters Standard Functions A015 A220A241 A021 ~ A035A242 A043A243 A044A058 A059A061 A261A072 A073A074 A075A092 A292A093 A293A131 A132A141 A142A156 A157A161 A162Fine Tuning Functions B012 B212B013 B213B025 B026B027 B028B037 B038B039 B040B060 B061B062 B063B087 B088B089 B090B096 B097B100 B101B133 B134B145 B150Intelligent Terminal Functions C028 C030C031 C032C047 C052C053 C054C076 C077C078 C081C102 C103C104 C105C147 C148C149 C150Anlg FWD, REVPidc DWNSF1 SF2SF3 SF4255 Run Signal When the inverter is in Run Mode LOG2 LOG1LOG3 C039 MO1MO2 MO3Motor Constants Functions PM Motor Constants Functions H112 H113H116 H117Expansion Card Functions P041 P044P045 P046P072 P073P075 P077Monitoring Trip Events, History, & Conditions Trip History and Inverter StatusError Codes Error Name Causes CodeE37 Error Name Descriptions Code Restoring Factory Default SettingsOther indication CE-EMC Installation Guidelines Important notesPage Page Installation for WJ200 series example of SF models Metal plate earthHitachi EMC Recommendations Functional Safety Certification in Progress IntroductionStop Category defined in EN60204-1 How it worksInstallation Wiring example OFF G9SX GS9ANE1A