Bosch Appliances KTS 340 Technical data, General data, Interface protocols, Power supply unit

Page 17

Technical data TS

17

 

en

 

 

 

 

 

7.Technical data

7.1

General data

 

 

 

 

Property

 

Value/Range

 

 

Operating voltage

11 VDC — 34 VDC

Power consumption

approx. 50 W

LCD

 

8.4"

 

 

800 x 600 pixels

Dimensions (L x W x H)

235 x 290 x 67 mm

 

 

9.25 x 11.42 x 2.64 inch

 

 

Weight (without connecting cables)

2100 g

 

 

4.6 lb

Operating temperature

5 °C – 40 °C

 

 

41 °F – 104 °F

Relative humidity

90 % (at 25 °C)

Degree of protection

IP 40

7.2Interface protocols

The following interfaces and their associated protocols are supported for control unit diagnosis in compliance with ISO 15031:

RR ISO/DIS 15765-4 (CAN) - baud rates: 250 kbit/s and 500 kbit/s)

RR ISO 9141-2 Fast

RR ISO/DIS 14230-4 (keyword protocol 2000) 5 bauds RR ISO/DIS 14230-4 (keyword protocol 2000) Fast

RR ISO/DIS 11519-4 (SAE J1850) PWM

RR ISO/DIS 11519-4 (SAE J1850) VPW

7.3Power supply unit

Property

Value/Range

 

 

Input voltage

100 VAC — 240 VAC

 

 

 

Input frequency

50

Hz — 60 Hz

 

 

 

Output voltage

15

V

 

 

Operating temperature

0 °C — 40 °C

 

 

 

7.4Multimeter specifications

RR CH1 zero potential (blue input may be connected to live measurement points). Input resistance

> 900 kohms.

RR CH2 non-floating (black ground input must be connected to vehicle ground). Input resistance > 900 kohms.

7.4.1DC measurement (CH1 and CH2)

Property

Value/Range

 

 

Measuring range

200 mV — 60 V

Accuracy of CH1

±0.75 % of measured value,

 

plus ±0.25 % of measuring range

Accuracy of CH2

±2 % of measured value,

 

plus ±0.5 % of measuring range

Resolution

100 µV — 100 mV

 

(depending on measuring range)

7.4.2Measurement of AC and rms value (CH1 and CH2)*)

Property

Value/Range

 

 

AC frequency range

10 Hz — 400 Hz (-3 dB)

Measuring range

200 mV — 60 V

AC accuracy at 100 Hz

±2 % of measured value, plus

rms accuracy at ≤ 100 H

±0.5 % of measuring range

 

Resolution

100 µV — 100 mV (depending

 

on measuring range)

*)

The measuring ranges in measurement modes "U" and "I" are

 

specified as peak-to-peak values. Consequently, the digital

 

display box is "grayed out" if the set measuring range is briefly

 

exceeded (overload).

7.4.3Resistance measurement (CH1)

Property

Value/Range

 

 

Measuring range

100 — 1 M

Accuracy up to 200 K

±0.75 % of measured value

 

plus ±0.25 % of measuring ran-

 

ge

Accuracy up to 1 M

±2 % of measured value

 

plus ±0.25 % of measuring ran-

 

ge

Resolution

0.1 — 1000 (depending on

 

measuring range)

Input resistance

> 9 M

Robert Bosch LLC

1 689 989 072 2010-04-06

Image 17
Contents KTS Page  TS Contents English Sommaire Français Índice EspañolContents User information Symbols usedKTS 340 Symbols used Wlan Wireless Local Area NetworkProduct description Special accessoriesUse Scope of deliveryDescription of the unit Battery charge LEDLED status KTS 340 Product descriptionConnection IiThe selected installation language will also beLicensing with the ESItronic Startcenter Commissioning TSKTS 340 Commissioning Under Service User setting Language settingLicensing the KTS 340 online KTS 340 Commissioning Operation KTS 340 fax licensing procedureConnection to the vehicle Licensing the KTS 340 by faxSwitching off Switching onTouchscreen with stylus Program descriptionFaults Software updateOpen the Settings Online updates input box KTS 340 software updateCleaning MaintenanceRechargeable battery replacement En 16 KTS 340 MaintenancePower supply unit Technical dataMultimeter specifications General dataWlan KTS 340 Technical dataCurrent measurement CH1 and CH2 Continuity tester CH1Page Sommaire Consignes dutilisation Symboles utilisésRemarques importantes sur Wlan KTS 340 Symboles utilisésRemarques sur la borne daccès Remarques sur Wlan pour le Canada CanadaDescription du produit Accessoires spéciauxApplication Conditions préalablesEtat des LED Description de lappareilKTS 340 Description du produit LED état de charge de laccumulateurPremière mise en service TS Première mise en serviceInstallation de ESItronic Startcenter Marche à suivre RaccordementKTS 340 Première mise en service Sélectionner le menu Enregistrement de licence Enregistrement de la licence du KTS 340 en ligneGénérer Enregistrer la licence du KTS 340 par télécopie UtilisationRaccordement au véhicule Mise à l’arrêt Mise en marcheRemarques relatives au multimètre Ecran tactile avec stylo tactileRemarques en cas de défauts Mise à jour du logicielUtilisation TS Mise à jour du logiciel du KTSFr 32 KTS 340 Maintenance Remplacement des accumulateursNettoyage Pièces de rechange et dusureCaractéristiques générales Caractéristiques techniquesProtocoles dinterface Bloc d’alimentationMesure du courant CH1 et CH2 KTS 340 Caractéristiques techniquesTesteur de continuité CH1 Mesure des diodes CH1Page Índice Indicaciones para el usuario Símbolos empleadosKTS 340 Símbolos empleados Descripción del producto Volumen de suministroUtilización RequisitosLED estado Descripción del equipoKTS 340 Descripción del producto LED estado de carga acumuladorConexión Primera puesta en servicioActivar licencia con ESItronic Startcenter Primera puesta en servicio TSKTS 340 Primera puesta en servicio Licencia Online Activación de licencia del KTS 340 onlineGenerar Conexión al vehículo ManejoApagar EncenderIndicaciones sobre el multímetro Pantalla táctil con lápiz táctilInstrucciones en caso de avería Actualización del softwareManejo TS Paso 2 Actualización de software del KTSLimpieza MantenimientoSustitución del acumulador Piezas de repuesto y de desgasteDatos generales Datos técnicosProtocolo de interfaces Fuente de alimentaciónMedición de corriente CH1 y CH2 KTS 340 Datos técnicosVerificador de paso CH1 Medición de diodos CH1Page Robert Bosch LLC