Technical data �TS | 17 |
| en |
| |||
|
|
|
|
7.Technical data
7.1 | General data |
|
|
|
|
Property |
| Value/Range |
|
| |
Operating voltage | 11 VDC — 34 VDC | |
Power consumption | approx. 50 W | |
LCD |
| 8.4" |
|
| 800 x 600 pixels |
Dimensions (L x W x H) | 235 x 290 x 67 mm | |
|
| 9.25 x 11.42 x 2.64 inch |
|
| |
Weight (without connecting cables) | 2100 g | |
|
| 4.6 lb |
Operating temperature | 5 °C – 40 °C | |
|
| 41 °F – 104 °F |
Relative humidity | 90 % (at 25 °C) | |
Degree of protection | IP 40 |
7.2Interface protocols
The following interfaces and their associated protocols are supported for control unit diagnosis in compliance with ISO 15031:
RR ISO/DIS
RR ISO
RR ISO/DIS
RR ISO/DIS
RR ISO/DIS
7.3Power supply unit
Property | Value/Range | |
|
| |
Input voltage | 100 VAC — 240 VAC | |
|
|
|
Input frequency | 50 | Hz — 60 Hz |
|
|
|
Output voltage | 15 | V |
|
| |
Operating temperature | 0 °C — 40 °C | |
|
|
|
7.4Multimeter specifications
RR CH1 zero potential (blue input may be connected to live measurement points). Input resistance
> 900 kohms.
RR CH2
7.4.1DC measurement (CH1 and CH2)
Property | Value/Range |
|
|
Measuring range | 200 mV — 60 V |
Accuracy of CH1 | ±0.75 % of measured value, |
| plus ±0.25 % of measuring range |
Accuracy of CH2 | ±2 % of measured value, |
| plus ±0.5 % of measuring range |
Resolution | 100 µV — 100 mV |
| (depending on measuring range) |
7.4.2Measurement of AC and rms value (CH1 and CH2)*)
Property | Value/Range |
|
|
AC frequency range | 10 Hz — 400 Hz |
Measuring range | 200 mV — 60 V |
AC accuracy at 100 Hz | ±2 % of measured value, plus |
rms accuracy at ≤ 100 H | ±0.5 % of measuring range |
| |
Resolution | 100 µV — 100 mV (depending |
| on measuring range) |
*) | The measuring ranges in measurement modes "U" and "I" are |
| specified as |
| display box is "grayed out" if the set measuring range is briefly |
| exceeded (overload). |
7.4.3Resistance measurement (CH1)
Property | Value/Range |
|
|
Measuring range | 100 — 1 M |
Accuracy up to 200 K | ±0.75 % of measured value |
| plus ±0.25 % of measuring ran- |
| ge |
Accuracy up to 1 M | ±2 % of measured value |
| plus ±0.25 % of measuring ran- |
| ge |
Resolution | 0.1 — 1000 (depending on |
| measuring range) |
Input resistance | > 9 M |
Robert Bosch LLC | 1 689 989 072 |