1
12
13
14
15
1Using the side handles, open the top cover.
2Firmly lift the two green handles on either side of the fuser to disengage the fuser rollers.
3Grasp the media by both corners and pull to remove it.
Note If the media tears, make sure that all media fragments are removed from the paper path before resuming printing. Do not reach into the fuser until it has cooled.
4Grasp the green handle on the transfer unit and pull down. The front cover will open as the transfer unit is pulled down.
CAUTION Do not place anything on the transfer unit while it is open. If the transfer unit is punctured, print quality problems may result.
5Grasp the media by both corners and pull down. If the media appears to be crumpled in the fuser, go to step six.
ENWW | 167 |