Wayne-Dalton 3663-372 Attaching Disconnect Handle, Disconnect Handle Usage

Page 22

8Attaching Disconnect Handle

Tools Needed:

NOTE: The motor must be in the fully down

position before setting handle position on

 

Phillips

cable. Bring motor to the down position by

pulling the disconnect cable while pushing

Head

the motor down. Insure opener disconnect

Screwdriver

teeth are engaged before installing

Wire Cutters

disconnect handle. If motor is not fully down

when teeth are engaged, turn motor shaft

Flat Blade

with screwdriver at back of motor counter

clockwise until motor is fully down.

Screwdriver

NOTE: Do not use power drill to assemble

 

 

set screw to handle.

 

Start the #6-20 x 1/2" screw into the

 

disconnect handle. Thread the disconnect

 

cable through the top of the disconnect

 

handle bracket and then the disconnect

 

handle.

 

Locate the disconnect handle in full upper

 

position of disconnect handle bracket.

 

Remove all disconnect cable slack between

 

the opener and the top of the disconnect

 

handle bracket. Tighten #6-20 x 1/2" screw

 

into the disconnect handle until snug, and

 

then tighten screw an additional 1 to 1-1/2

 

turns to secure disconnect cable to the

 

disconnect handle. Trim off excess cable

 

from bottom of the disconnect handle.

 

CAUTION: PULL CABLE ONLY TAUT

 

ENOUGH TO REMOVE THE CABLE SLACK.

 

PULLING THE CABLE MORE COULD CAUSE

 

OPENER TO DISCONNECT FROM THE

 

TORQUE TUBE AND CAUSE FAILURE OF THE

 

DISCONNECT.

Upper

Position

#6-20 x 1/2”

Screw

Disconnect

Handle

Disconnect

Cable Disconnect

Handle

Bracket

9

Tools Needed:

None

Disconnect Handle Usage

Apply emergency disconnect label next to the mounted bracket. Use mechanical fasteners if adhesive will not adhere.

Using the emergency disconnect, pull down on disconnect handle and place it in the manual door operated position (use disconnect label for reference). Motor will be rotated 90° from its packaged position.

If motor does not pivot 90°, see troubleshooting section in this manual.

Manual operated position

Motor operated position

Emergency

Disconnect

Label

15Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.

You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Image 22
Contents Important Notice Copyright 2008 Wayne-Dalton Corp Rev 7 7/16/2008Counterbalance above door From bottom Closed door Idrive mounts to Lift cables raise doorSecurity arm manually locks Package Contents When Installing a NEW Door with AN Idrive Look for this symbolInspection Pre-InstallationEyes to Prevent Possible Severe or Fatal Injury WAYNE-DALTON Track Radius Photoelectric LOW Head System RequirementsTools Needed 10,12,14,15Table of Contents Definition of key words used in this manualDrum Wrap & End Bracket Retro-Fit InstallationSpring Tension Removal RemovalRemoval End Bracket RemovalTorquemaster Plus Center Bracket & Cable DrumRetro-Fit Installation RETRO-FIT Torquemaster End Bracket RemovalTop Bracket Re-Install If NecessaryVertical Track Height Adjustment 8000/8100/8200 TrackFailure to RE-ATTACH Horizontal RETRO-FIT InstallationsTop Roller Adjustment Tracks to the Support Before Opening Door can Cause DoorInstallation Assembling OpenerCable Drums Torquemaster InstallationIdrive for End Brackets BracketsIdrive for Torquemaster Installation InstallationCable Drum/ Drive Gear End Bracket Installation Counterbalance SpringsAttaching Opener To InstallationPositioning Support Bracket Support BracketSlack between opener and right end Attaching Disconnect CablePliers PliersHandle Bracket Pilot drill lag screw location using 1/8 drill bitMounting Disconnect 6ftDisconnect Handle Usage Attaching Disconnect HandleDisconnect Cable Adjustments Aligned and SeatedFor Spring Winding Securing DoorTools Needed Vice Clamps Winding Springs HandsRecommended Spring Turns Drum Wrap InstallationIMPORTANT! do not Overwind Springs Tools Needed Step LadderSetting Spring Tension IMPORTANT! do not OverwindMounting Wall Station Garage DoorInstalling Battery PRE-OPERATIONInstalling the Light Fixture Power Cord Connecting OpenerAttaching Diffuser For Proper Alignment Photoelectric Eyes are notSensor Unit Sensor Wire Installation View of the Opener from the FrontSecuring the Opener Safety Sensor AlignmentChecking for Obstructions Profile Routine Standard Upper Limit On when program button is pushedProgramming Light Fixture On and remain on for 30 secondsCustom Upper Limit Adjusting DetentProfile Routine Work ProperlyLock Arm Installation OperationLock Arm Installation Contact Obstruction TestTesting the Safety Sensors Fatal Injury MAY ResultEmergency Disconnect Read and Follow ALL InstructionsDoor activation Never GO Under a STOPPED, Partially Open DoorOperating the Wireless Wall Station Programming/Training HomeLink Unit Teaching HomeLink to the idrive openerOperation Multi-Door Programming Customizing the SettingsCustom pet position For more profile options go to page 28Maintenance Reconnect Power Power Connection Permanent Wiring OptionConfirm pot nut position* shown below Programming Remote Controls Stations or Transmitters to OpenerProgramming Wireless WallOPENER, Using the Emergency Disconnect Handle Prior toTroubleshooting Symptom Probable Cause Corrective ActionLock Arm Troubleshooting TroubleshootingoperationDalton dealer or distributor Drill Template Cut-Out Template to Aid InstallationPre-drill 3/32 pilot hole Pre-drill 5/64 pilot holePatent Information