Wayne-Dalton 3663-372 installation instructions Lock Arm Installation, Contact Obstruction Test

Page 38

Lock Arm Installation

(Continued)

Once track radius has been determined, secure the lock arm to the motor with

(1) 5mm x .8mm phillips pan head screw.

NOTE: If unsure of track radius, begin with lock arm in position 1.

After assembly of the lock arm, manually raise and lower the door and verify that the lock arm does not interfere with the door. If there is interference between the door and the lock arm, see Page 42 for lock arm troubleshooting.

NOTE: Do not operate the door or opener if there is interference between the lock arm and the door.

Reconnect the door to the motor operated position. Activate a motor operated up/down cycle to confirm clearance.

Lock Arm

Motor

5mm x 8mm

Phillips

Pan Screw

28

Contact Obstruction Test

 

 

 

Tools Needed:

After installing the opener, the door must

2 x 4 Board

reverse when it contacts a 1-1/2” high

object (or a 2 x 4 board laid flat) on the

 

 

garage floor.

 

Using the wall station, activate the door

 

to the fully open position.

 

Place a 2 x 4 board flat on the garage

 

floor, under the door path.

 

Activate the door to the closed position

 

with the wall station. Upon contacting the

 

2 x 4 board, the door should stop, then

 

reverse direction within two seconds and

 

travel to the full open position.

 

If the door does not respond to the

 

required tests, repeat profile routine Step

 

24 or 25, making sure the door is in the

 

fully closed position prior to activation.

 

 

Center Of Door

2 x 4 Laid Flat

On Floor

WARNING

IF OPENER DOES NOT RESPOND PROPERLY TO THESE TESTS (STEPS

28 AND 29), DO NOT USE DOOR UNTIL A QUALIFIED SERVICE PERSON HAS MADE NECESSARY ADJUSTMENTS/REPAIRS, OR SEVERE OR FATAL INJURY COULD RESULT FROM OPERATING THE DOOR/OPENER.

31Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.

You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Image 38
Contents Important Notice Copyright 2008 Wayne-Dalton Corp Rev 7 7/16/2008Security arm manually locks Idrive mounts to Lift cables raise doorCounterbalance above door From bottom Closed door Package Contents When Installing a NEW Door with AN Idrive Look for this symbolEyes to Prevent Possible Severe or Fatal Injury Pre-InstallationInspection WAYNE-DALTON Track Radius Photoelectric LOW Head System RequirementsTools Needed 10,12,14,15Table of Contents Definition of key words used in this manualDrum Wrap & End Bracket Retro-Fit InstallationSpring Tension Removal RemovalRemoval End Bracket RemovalTorquemaster Plus Center Bracket & Cable DrumRetro-Fit Installation RETRO-FIT Torquemaster End Bracket RemovalTop Bracket Re-Install If NecessaryVertical Track Height Adjustment 8000/8100/8200 TrackFailure to RE-ATTACH Horizontal RETRO-FIT InstallationsTop Roller Adjustment Tracks to the Support Before Opening Door can Cause DoorInstallation Assembling OpenerIdrive for Torquemaster InstallationCable Drums End Brackets BracketsCable Drum/ Drive Gear InstallationIdrive for Torquemaster Installation End Bracket Installation Counterbalance SpringsAttaching Opener To InstallationPositioning Support Bracket Support BracketSlack between opener and right end Attaching Disconnect CablePliers PliersHandle Bracket Pilot drill lag screw location using 1/8 drill bitMounting Disconnect 6ftDisconnect Attaching Disconnect HandleDisconnect Handle Usage Cable Adjustments Aligned and SeatedTools Needed Vice Clamps Securing DoorFor Spring Winding Winding Springs HandsRecommended Spring Turns Drum Wrap InstallationIMPORTANT! do not Overwind Springs Tools Needed Step LadderSetting Spring Tension IMPORTANT! do not OverwindMounting Wall Station Garage DoorInstalling Battery PRE-OPERATIONInstalling the Light Fixture Attaching Diffuser Connecting OpenerPower Cord Sensor Unit Photoelectric Eyes are notFor Proper Alignment Sensor Wire Installation View of the Opener from the FrontChecking for Obstructions Safety Sensor AlignmentSecuring the Opener Profile Routine Standard Upper Limit On when program button is pushedProgramming Light Fixture On and remain on for 30 secondsCustom Upper Limit Adjusting DetentProfile Routine Work ProperlyLock Arm Installation OperationLock Arm Installation Contact Obstruction TestTesting the Safety Sensors Fatal Injury MAY ResultEmergency Disconnect Read and Follow ALL InstructionsDoor activation Never GO Under a STOPPED, Partially Open DoorOperating the Wireless Wall Station Programming/Training HomeLink Unit Teaching HomeLink to the idrive openerOperation Multi-Door Programming Customizing the SettingsCustom pet position For more profile options go to page 28Maintenance Confirm pot nut position* shown below Power Connection Permanent Wiring OptionReconnect Power Programming Remote Controls Stations or Transmitters to OpenerProgramming Wireless WallOPENER, Using the Emergency Disconnect Handle Prior toTroubleshooting Symptom Probable Cause Corrective ActionLock Arm Troubleshooting TroubleshootingoperationDalton dealer or distributor Drill Template Cut-Out Template to Aid InstallationPre-drill 3/32 pilot hole Pre-drill 5/64 pilot holePatent Information