Definition of key words used in this manual:
WARNING
INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN SEVERE OR FATAL INJURY.
CAUTION: PROPERTY DAMAGE OR INJURY CAN RESULT FROM FAILURE TO FOLLOW INSTRUCTIONS.
IMPORTANT: REQUIRED STEP FOR SAFE AND PROPER DOOR OPERATION.
NOTE: Information assuring proper installation of the door.
WARNING
INCORRECT INSTALLATION CAN LEAD TO SEVERE OR FATAL INJURY. FOLLOW THESE INSTRUCTIONS CAREFULLY.
IMPORTANT SAFETY INSTRUCTIONS
1.READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2.Do not connect the opener to electrical power until instructed to do so.
3.Install the entrapment warning label next to the wall station in a prominent location. Install the emergency disconnect label next to the emergency disconnect.
4.Remove all ropes and remove, or make inoperative in the unlocked position, all locks connected to the garage door before installing the opener.
5.Do not wear rings, watches or loose clothing when installing or servicing a garage door system.
6.It is important that you install all the components supplied with the idrive® opener, i.e., wall stations, safety sensors, etc. Use
of parts not supplied by
7.Wear safety glasses for eye protection when installing or servicing the opener or door.
8.Install opener on a properly balanced and operating garage door. Have a qualified service person make adjustments/repairs to cables, spring assemblies, and other hardware before installing the opener. An improperly balanced door could cause severe injury.
9.Where possible, install the opener seven feet or more above the floor. Mount the emergency disconnect six feet above the floor.
10.Locate the wall station: (a) within sight of door, (b) at a minimum height of five feet, so small children cannot reach it, and (c) away from all moving parts of the door.
11.After installing the opener, the door must reverse when it contacts a 1- 1/2” high object (or 2 x 4 board laid flat) on the floor.
12.Installation and wiring must comply with local building and electrical codes. Connect the power cord to a properly grounded outlet. Do not remove the ground pin from power cord.
AFTER INSTALLATION IS COMPLETE, FASTEN THIS MANUAL NEAR GARAGE DOOR. PERFORM MONTHLY OBSTRUCTION TEST AND MAINTENANCE AS RECOMMENDED. SEE PAGES 31, 32 AND 38.
Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need. V You can reach us Toll Free at