21 | Safety Sensor Alignment |
|
| Top View |
In | In |
Tools Needed:
Pliers
Align the safety sensors by moving the sending and receiving units in or out until the alignment light on the receiving unit comes on. The
Once the alignment light comes on, tighten all bolts and mounting screws. Finish securing all wires making sure not to break or open any of the conductors. Loop and secure any excess wire.
Out | Out |
| |
| Bolts |
| For this adjustment, bend |
| Bracket at wall mount |
| Top View |
22 | Securing the Opener |
| |
| and Checking for Obstructions |
|
|
Tools Needed:
7/16” Wrench
Step Ladder
With the emergency disconnect still in the manual door operated position, manually raise the door to the fully open position. Then, manually lower the door to the fully closed position verifying freedom of movement and good door balance.
Tighten both
NOTE: Good door balance and freedom of movement are essential for proper opener performance. If door is heavy to lift, hard to close or if door sticks or binds in
the track, make proper adjustments now.
Support | 1/4” - 20 |
Bracket | Flange Nuts |
27Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.
You can reach us Toll Free at