Wayne-Dalton Wayne Dalton Torquemaster Spring Installation Instructions for Your Garage Door Opener

Page 23

10

Cable Adjustments

 

Tools Needed:

Starting on the right hand side, rotate the

Pliers/Wire

cable drum until the set screw faces

directly away from the header. Torque tube

Cutter

cam peak should be pointing straight up.

 

Flat Tip

NOTE: Illustrations show the right hand

Screwdriver

cable drum, left hand cable drum is

 

Locking Pliers

symmetrically opposite.

Step Ladder

NOTE: Cable tension is set during the initial

 

door installation. If there is slack between

 

the counterbalance cable and the cable

 

drum or unequal tension between the right

 

and left hand counterbalance cables, the

Torquemaster®

1/2 Wrap Shown

Counterbalance Cable

Cam Peak

Straight Up

First

Groove

Right Hand Drum

Cut Cable Here

Set Screw

6”

counterbalance cables will have to be

readjusted. If there is no slack and cable

tension is equal, proceed to Step 11.

Loosen the set screw no more than 1/2

turn. Using locking pliers, pull on the end of

the cable to remove all cable slack.

Check to ensure the cable is aligned and

seated in the first groove of the cable drum.

Snug the set screw, and then tighten an

additional 1-1/2 turns. Left side will be

Torquemaster® Plus

1-1/2 Wrap Shown

Cut Cable Here

Counterbalance Cable

Cam Peak

Straight Up

First Groove

Right Hand Drum

Set Screw

INSTALLATION

adjusted in Step 12.

IMPORTANT! ENSURE THE CABLE IS

ALIGNED AND SEATED IN THE

APPROPRIATE GROOVE(S) OF THE CABLE

DRUM PRIOR TO WINDING SPRINGS.

Measure approximately 6” of cable, cut off

excess cable, tuck end into cable drum

(Torquemaster®) or insert end in hole of

cable drum (Torquemaster® Plus).

Hole

6”

IDRIVE® FOR TORQUEMASTER®

Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need. 16 You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Image 23
Contents Copyright 2008 Wayne-Dalton Corp Rev 7 7/16/2008 Important NoticeSecurity arm manually locks Idrive mounts to Lift cables raise doorCounterbalance above door From bottom Closed door Package Contents Look for this symbol When Installing a NEW Door with AN IdriveEyes to Prevent Possible Severe or Fatal Injury Pre-InstallationInspection 10,12,14,15 System RequirementsTools Needed WAYNE-DALTON Track Radius Photoelectric LOW HeadDefinition of key words used in this manual Table of ContentsRemoval Retro-Fit InstallationSpring Tension Removal Drum Wrap & End BracketCenter Bracket & Cable Drum End Bracket RemovalTorquemaster Plus RemovalRetro-Fit Installation End Bracket Removal RETRO-FIT Torquemaster8000/8100/8200 Track Re-Install If NecessaryVertical Track Height Adjustment Top BracketTracks to the Support Before Opening Door can Cause Door RETRO-FIT InstallationsTop Roller Adjustment Failure to RE-ATTACH HorizontalAssembling Opener InstallationIdrive for Torquemaster InstallationCable Drums Brackets End BracketsCable Drum/ Drive Gear InstallationIdrive for Torquemaster Installation Counterbalance Springs End Bracket InstallationSupport Bracket InstallationPositioning Support Bracket Attaching Opener ToPliers Attaching Disconnect CablePliers Slack between opener and right end6ft Pilot drill lag screw location using 1/8 drill bitMounting Disconnect Handle BracketDisconnect Attaching Disconnect HandleDisconnect Handle Usage Aligned and Seated Cable AdjustmentsTools Needed Vice Clamps Securing DoorFor Spring Winding Hands Winding SpringsTools Needed Step Ladder Drum Wrap InstallationIMPORTANT! do not Overwind Springs Recommended Spring TurnsIMPORTANT! do not Overwind Setting Spring TensionGarage Door Mounting Wall StationPRE-OPERATION Installing BatteryInstalling the Light Fixture Attaching Diffuser Connecting OpenerPower Cord Sensor Unit Photoelectric Eyes are notFor Proper Alignment View of the Opener from the Front Sensor Wire InstallationChecking for Obstructions Safety Sensor AlignmentSecuring the Opener On and remain on for 30 seconds On when program button is pushedProgramming Light Fixture Profile Routine Standard Upper LimitWork Properly Adjusting DetentProfile Routine Custom Upper LimitOperation Lock Arm InstallationContact Obstruction Test Lock Arm InstallationFatal Injury MAY Result Testing the Safety SensorsNever GO Under a STOPPED, Partially Open Door Read and Follow ALL InstructionsDoor activation Emergency DisconnectOperating the Wireless Wall Station Teaching HomeLink to the idrive opener Programming/Training HomeLink UnitOperation For more profile options go to page 28 Customizing the SettingsCustom pet position Multi-Door ProgrammingMaintenance Confirm pot nut position* shown below Power Connection Permanent Wiring OptionReconnect Power Disconnect Handle Prior to Stations or Transmitters to OpenerProgramming Wireless WallOPENER, Using the Emergency Programming Remote ControlsSymptom Probable Cause Corrective Action TroubleshootingTroubleshootingoperation Lock Arm TroubleshootingDalton dealer or distributor Pre-drill 5/64 pilot hole Cut-Out Template to Aid InstallationPre-drill 3/32 pilot hole Drill TemplatePatent Information