Customizing the Settings

 

Custom pet position:

Normal install routine sets the pet position to approximately 8 inches above the ground. The pet opening height may be changed to open anywhere between 8” and 30” above the ground. To change the automatic pet opening height refer to the following procedure:

a. After completion of the normal install routine, with the door in the closed position, place the disconnect handle in the manual operated position.

Manually position the door to the desired pet opening height (between 8” and 30” above ground) and return disconnect handle to the motor operated position.

b. Move the slide switch from the NORMAL (Unlock) position to the DOOR LOCK (Lock) position and then back to the NORMAL (Unlock) position. The opener will beep once. The pet button is now programmed to automatically open the door to this custom height.

NOTE: The opener will NOT accept programmed pet lock position if door is below 8” or higher than 30”.

NOTE: Activation of the normal install routine will reset the pet position to the default 8” target height. For use of the pet button see operation section.

Multi-Door Programming:

Momentarily pressing the button programmed in the transmitter programming step activates the door. Other buttons can also be programmed to activate different doors, for multi-door installations. Each button or a combination of two buttons pressed simultaneously can be programmed to activate a different door. Only one button at a time can be programmed to activate a specific opener.

Custom Upper Limits

Disconnect door and manually move it to the desired upper limit. NOTE: The door must be positioned more than halfway open. Reconnect door.

Press and hold the profile button for 5 seconds. The opener will beep twice, indicating the activation of the profile routine. The door will now move to the closed position. Then, the door will open to the new upper limit.

Next, the door will go down to the closed position. Once this is complete, the door limits are set and the installation is complete.

For more profile options go to page 28 and 29.

NOTE: Before performing custom upper limit, first profile must be done from closed position.

NORMAL

 

DOOR LOCK

 

Up/Down Button

 

Pet Button

 

Up/Down Button

Profile Button

 

37Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.

You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Image 44
Contents Important Notice Copyright 2008 Wayne-Dalton Corp Rev 7 7/16/2008Security arm manually locks Idrive mounts to Lift cables raise doorCounterbalance above door From bottom Closed door Package Contents When Installing a NEW Door with AN Idrive Look for this symbolEyes to Prevent Possible Severe or Fatal Injury Pre-InstallationInspection System Requirements Tools NeededWAYNE-DALTON Track Radius Photoelectric LOW Head 10,12,14,15Table of Contents Definition of key words used in this manualRetro-Fit Installation Spring Tension RemovalDrum Wrap & End Bracket RemovalEnd Bracket Removal Torquemaster PlusRemoval Center Bracket & Cable DrumRetro-Fit Installation RETRO-FIT Torquemaster End Bracket RemovalRe-Install If Necessary Vertical Track Height AdjustmentTop Bracket 8000/8100/8200 TrackRETRO-FIT Installations Top Roller AdjustmentFailure to RE-ATTACH Horizontal Tracks to the Support Before Opening Door can Cause DoorInstallation Assembling OpenerIdrive for Torquemaster InstallationCable Drums End Brackets BracketsCable Drum/ Drive Gear InstallationIdrive for Torquemaster Installation End Bracket Installation Counterbalance SpringsInstallation Positioning Support BracketAttaching Opener To Support BracketAttaching Disconnect Cable PliersSlack between opener and right end PliersPilot drill lag screw location using 1/8 drill bit Mounting DisconnectHandle Bracket 6ftDisconnect Attaching Disconnect HandleDisconnect Handle Usage Cable Adjustments Aligned and SeatedTools Needed Vice Clamps Securing DoorFor Spring Winding Winding Springs HandsDrum Wrap Installation IMPORTANT! do not Overwind SpringsRecommended Spring Turns Tools Needed Step LadderSetting Spring Tension IMPORTANT! do not OverwindMounting Wall Station Garage DoorInstalling Battery PRE-OPERATIONInstalling the Light Fixture Attaching Diffuser Connecting OpenerPower Cord Sensor Unit Photoelectric Eyes are notFor Proper Alignment Sensor Wire Installation View of the Opener from the FrontChecking for Obstructions Safety Sensor AlignmentSecuring the Opener On when program button is pushed Programming Light FixtureProfile Routine Standard Upper Limit On and remain on for 30 secondsAdjusting Detent Profile RoutineCustom Upper Limit Work ProperlyLock Arm Installation OperationLock Arm Installation Contact Obstruction TestTesting the Safety Sensors Fatal Injury MAY ResultRead and Follow ALL Instructions Door activationEmergency Disconnect Never GO Under a STOPPED, Partially Open DoorOperating the Wireless Wall Station Programming/Training HomeLink Unit Teaching HomeLink to the idrive openerOperation Customizing the Settings Custom pet positionMulti-Door Programming For more profile options go to page 28Maintenance Confirm pot nut position* shown below Power Connection Permanent Wiring OptionReconnect Power Stations or Transmitters to OpenerProgramming Wireless Wall OPENER, Using the EmergencyProgramming Remote Controls Disconnect Handle Prior toTroubleshooting Symptom Probable Cause Corrective ActionLock Arm Troubleshooting TroubleshootingoperationDalton dealer or distributor Cut-Out Template to Aid Installation Pre-drill 3/32 pilot holeDrill Template Pre-drill 5/64 pilot holePatent Information