Conair GB/ WSB manual Part Operation Load Cell Calibration, Be Sure, Cal Off, Zero WT

Page 14

+

--------------------------------------------------------------------

+

¦

PART II

- OPERATION

¦

+

--------------------------------------------------------------------

+

 

LOAD CELL

CALIBRATION

 

NOTE: Display examples shown here are in tenths of grams as displayed On 100 and 200 series models. 400, 900 and 1800 series models display full grams, no decimal.

If your

load cells are displaying a weight close to (

0.0), plus or

minus 5

grams, you may skip this section and go directly to

RATE CALIBRATION (next page).

 

 

If your

unit DOES NOT

display a weight of (

0.0) grams, plus or

minus 5

grams, you should recalibrate them, that is reset

ZERO weight,

at this

time.

 

 

 

 

To do so:

 

 

 

 

BE SURE

the weigh bin

is EMPTY.

 

 

BE SURE

the load cell

plug is plugged into the side of the controller.

BE SURE

the weigh bin

is resting on the load cells freely.

 

BE SURE

the air line to the dump valve is connected as it

would be

 

during normal

operation. (A disconnected air line

adds weight.)

BE SURE

The load cells and bin are not jammed in any way.

To test for

 

this see

that

a light touch on the bin causes the

display to

 

change.

When

the pressure is removed the display

must return

to exactly where it was, plus or minus 0.1 gram.

If this does not happen, something is touching something and the bin is not entirely free to move. Check EVERYTHING around the bin.

LOAD CELL CALIBRATION:

 

 

 

 

The sequence of keystrokes is as follows:

 

 

 

+

------------------------------------------------------

 

 

 

+

¦

Press:

*

Display will say:

(PASSWORD)

¦

¦

Press:

22222

Display will say:

(P

x.x)

¦

¦

Press:

*99

Display will say:

(CAL

OFF)

¦

¦

Press:

*

Display will say:

(CAL

ON )

¦

¦

Press:

EXIT

Display will say:

(P

x.x)

¦

¦

Press:

ZERO WT

Display will say:

(--WAIT--)

¦

¦

 

 

followed by:

(P

0.0)

¦

+

------------------------------------------------------

 

 

 

+

The ZERO point of the load cells is now set properly. FULL weight calibration may also be done at this time, however, it probably is NOT NECESSARY. When load cell readings shift due to rough handling, the entire range of readings from ZERO to FULL shift together. ZERO weight calibration resets the full range of the cells and, therefore, corrects FULL weight readings as well. For information on FULL weight calibration, see RECALIBRATION OF LOAD CELLS section.

+

-----------------------------------------------------

 

+

¦

PROCEED TO:

RATE CALIBRATION

NEXT PAGE

¦

+

-----------------------------------------------------

 

+

Page 15

Image 14
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Four Component Software Part Troubleshooting / SoftwarePart Hardware Maintenance Part OperationSpecial Features Assembly InstructionsCheck OUT Procedure Proceed to Safety Hazards NextProceed to Assembly Next Safety Hazards MIX BladesSafety Features Safety Interlock Switch Additional MIX Blade HazardDisclaimers Please Be Careful Part AssemblyLoad Cells are Easily Damaged On the NextPage Wiring Considerations Proceed to Check OUT Procedure NextAT this Point Procedure What should Happen Plug in ControllerTurn Power on Touch Weigh BIN Very LightlyLED # Press Alarm KEYPress REG KEY Press NAT KEYPage Password ExitCAL OFF Part Operation Load Cell CalibrationBe Sure CALOperate Proceed to Normal Operation NextOper COLGB/WSB MB Selected Models Special InstructionsMicro Pulse GB/WSB 240RPower on If Problems DevelopPower OFF Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind Eight Character Display ROM OKAlarm Silence Right Column AlarmsStrobe Light and Beeper Alarms LED LightsMixer Motor Fuse Mixer Motor ON/OFF/TIMED SwitchMixer Motor Outlet Internal Fuses KeypadDate RUN Keypad Automatic Operation ModeRecipe RCPTABLE, FLG SaveBtch Page Fast TAGKeypad Manual Mode ALLTimed Time ADDPage Keypad Program Mode YLD Ctrl ParaStar Functions Page Page Page Page Page Page Page Page MIX Time ParametersParameter List Brief Explanations XXX RLO Page CPL Full Explanation of Parameters No ALARM, no Retries MPOMIX KDF / WDF BERPage ROV Page Example RHL is Set 10 percent Page Setting SETPage Page Page Page Page XTP XCV + XRCTCV + TRC XAL XULMCT PTDLIQ Page APO Parameter Default Settings Four SoftwareFLG RPO NPO CPO MPO RAL NAL CAL AAL MIX JOGNWT NPT CPT APT RWTRTI NTIChanging Parameters REG Natural COL Prnt OFFPrnt TotalFinal DISP,% What to Check for Page Page Page Time Natural Special TestsTime Calibrate NaturalDate Time Totals Grand PCT Current Material Usage InformationPARAMETER, PRT Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function CNT Load Cell RAW Signal ReadoutCNT OFF Results to Expect Core Dump Clear RoutineClear ALL Restart Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Wait Recalibration of Load CellsZero FullLoad Cells Blender Preventive MaintenanceDispense Gates Weigh BinsThese Instructions for Totalizers only Blender Special Totalizer FunctionStop END of Cycle TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Specifications Gravimetric Batch Blenders Autoweigh GBM Series ModelsGravimetric Batch Blenders AutoWeigh GB100 Series Models TOP View Front View Side View120V/1 phase/50-60 Hz 240V/1 phase/50-60 Hz Gravimetric Batch Blenders GB 220 and 420 ModelsGravimetric Batch Blenders AutoWeigh GB240 and GB440 Models TOP View Mounting InterfaceGravimetric Batch Blenders AutoWeigh GB900 Series Models 2124Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 Models GB1840 GB1860Gravimetric Batch Blenders Wsbm Series models Control Remote Mounted Models WSBM22 WSBM131 WSBM140Gravimetric Batch Blenders WSB 100 and 100R Models Side View Front View Side View, R Model Front View, R ModelGravimetric Batch Blenders WSB 220 and 420 Models 24.4Gravimetric Batch Blenders WSB 240/440 and 240/440R Models WSB442Gravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C