Conair GB/ WSB manual Eight Character Display, Rom Ok

Page 21

7.ALL AIR SOLENOID outputs

This is a single 17 pin Amphanol plug located on the front of the control panel. This provides 24 volt power for the NATURAL, REGRIND, WEIGH BIN DUMP, and FLOW CONTROL (optional) air solenoids. On Models 140, 240, 440, 940, and 1840 (FOUR valve units), COLOR and ADDITIVE dispense valve solenoids are also powered. These power sources are transistor driven and are protected by the 1/2 amp panel fuse. See the wiring diagram section for the correct wiring to each pin.

8.COLOR and ADDITIVE power outlets (certain models only)

Each outlet puts out 120 volts (220 volts outside U.S.A.) through internal plug-in solid state relays rated at 5 amps and fused at 3 amps. These relay outputs are designed to drive motors or other devices requiring power up to 3 amps each.

The COLOR outlet is driven based on the COLOR setting. The ADDITIVE outlet follows the ADDITIVE setting. COLOR dispense occurs first but has no effect on the ADDITIVE dispense. The amount of each dispense is calculated based on the NATURAL dispense that precedes them.

9.EIGHT CHARACTER DISPLAY

Displays the accumulated total bin weight, in grams, 2 seconds after each dispense. The display flashes when an inadequate dispense has occurred and the dispense is going to be retried. Other information displayed here includes material usage totals, internal parameters, current thumbwheel settings or keypay entered settings, and various information prompts to assist the operator.

####.#

Numbers displayed

are

the total weight

of material, in grams,

 

in the bin at

any

time. The weight in

the bin is updated 2

 

seconds after

an each

dispense is completed. During the

 

dispense the displayed weight does not

change.

Pin the left most position indicates unit is in PROGRAM mode.

M indicates unit is in MANUAL mode.

R, N, C, or A indicates the component being dispensed. INVALID indicates:

1.you pressed an incorrect key,

2.you pressed a key for a function that is not active, or

3.you are not in the right mode for this key to operate. PASSWORD is displayed when you press the "*" key from the normal mode.

Enter "11111" for MANUAL mode or "22222" for PROGRAM mode or enter your own password number if you have established one.

SETTING, OPERATE, TIMED, and CALIBRATE are displayed when the respective keys are pressed from the manual or program modes. These displays are followed by pressing a device key; REG, NAT, COL, ADD, DUMP, ALARM, MIX, or HOLD.

FLASHING means that retries are occurring because the first dispense was not enough. Other error conditions also cause flashing.

ROM OK

or ROM BAD indicates condition of ROM chip.

 

See KEYPAD, *25 for explanation.

Page 22

Image 21
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Part Hardware Maintenance Part Troubleshooting / SoftwareFour Component Software Part OperationCheck OUT Procedure Assembly InstructionsSpecial Features Proceed to Safety Hazards NextSafety Features Safety Interlock Switch Safety Hazards MIX BladesProceed to Assembly Next Additional MIX Blade HazardDisclaimers Load Cells are Easily Damaged Part AssemblyPlease Be Careful On the NextPage Proceed to Check OUT Procedure Next Wiring ConsiderationsTurn Power on Procedure What should Happen Plug in ControllerAT this Point Touch Weigh BIN Very LightlyPress REG KEY Press Alarm KEYLED # Press NAT KEYPage Exit PasswordBe Sure Part Operation Load Cell CalibrationCAL OFF CALOper Proceed to Normal Operation NextOperate COLMicro Pulse Selected Models Special InstructionsGB/WSB MB GB/WSB 240RPower OFF If Problems DevelopPower on Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind ROM OK Eight Character DisplayStrobe Light and Beeper Alarms Right Column AlarmsAlarm Silence LED LightsMixer Motor ON/OFF/TIMED Switch Mixer Motor OutletMixer Motor Fuse Keypad Internal FusesDate Recipe Keypad Automatic Operation ModeRUN RCPSave BtchTABLE, FLG Page TAG FastALL Keypad Manual ModeTime ADD TimedPage Keypad Program Mode Para Star FunctionsYLD Ctrl Page Page Page Page Page Page Page Page Parameters Parameter List Brief ExplanationsMIX Time XXX RLO Page CPL Full Explanation of Parameters MPO No ALARM, no RetriesMIX BER KDF / WDFPage ROV Page Example RHL is Set 10 percent Page SET SettingPage Page Page Page Page XCV + XRC TCV + TRCXTP XUL XALPTD LIQMCT Page FLG RPO NPO CPO Parameter Default Settings Four SoftwareAPO MPO RAL NAL CAL AAL MIX JOGRTI NPT CPT APT RWTNWT NTIChanging Parameters Prnt Prnt OFFREG Natural COL TotalFinal DISP,% What to Check for Page Page Page Time Special TestsTime Natural Calibrate NaturalPARAMETER, PRT Material Usage InformationDate Time Totals Grand PCT Current Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function Load Cell RAW Signal Readout CNT OFFCNT Results to Expect Clear Routine Clear ALL RestartCore Dump Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Zero Recalibration of Load CellsWait FullDispense Gates Blender Preventive MaintenanceLoad Cells Weigh BinsThese Instructions for Totalizers only Stop END of Cycle Special Totalizer FunctionBlender TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Gravimetric Batch Blenders Autoweigh GBM Series Models SpecificationsTOP View Front View Side View Gravimetric Batch Blenders AutoWeigh GB100 Series ModelsGravimetric Batch Blenders GB 220 and 420 Models 120V/1 phase/50-60 Hz 240V/1 phase/50-60 HzTOP View Mounting Interface Gravimetric Batch Blenders AutoWeigh GB240 and GB440 Models2124 Gravimetric Batch Blenders AutoWeigh GB900 Series ModelsGB1840 GB1860 Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 ModelsControl Remote Mounted Models WSBM22 WSBM131 WSBM140 Gravimetric Batch Blenders Wsbm Series modelsSide View Front View Side View, R Model Front View, R Model Gravimetric Batch Blenders WSB 100 and 100R Models24.4 Gravimetric Batch Blenders WSB 220 and 420 ModelsWSB442 Gravimetric Batch Blenders WSB 240/440 and 240/440R ModelsGravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C