Conair GB/ WSB manual

Page 42

Date:11/09/93

Time:17:22:01

Machine number: 002

Display Readout: P 500.0

This is useful for obtaining printed verification of load cell accuracy to comply with ISO-9000 and British Standards rules.

The recommended procedure is:

1.Place the unit into the Program mode.

2.Press *88 for printout of empty bin TARE weight.

3.Place a KNOWN CERTIFIED WEIGHT into the weight bin.

4.Press *88 again for printout with the weight added.

5.The different between the two weight printouts should equal the KNOWN CERTIFIED WEIGHT.

*89 Press (*,8,9) to select the desired weight unit (GRAMS, KILOGRAMS, OUNCES, POUNDS) for readout of data. Systems in the U.S.A. are supplied with POUND readout selected. KILOGRAMS is preferred for nearly all countries outside the U.S.A. GRAM or OUNCE readout is appropriate only for very short runs or short demonstrations.

Use the * key to walk through the four possible selections. Press EXIT when the weight unit you want is displayed.

*98 Press (*,9,8) to set flag for RAW SIGNAL readout in place of gram readout of scale weight. A raw signal readout is useful to demonstrate the extreme sensitivity of the load cells. The raw signal readout bypasses calibration math.

Load cell function can be monitored without concern for any improper weight calibration that may have been done.

Use the * key to toggle flag ON or OFF.

Power On will always set this flag to OFF.

Press EXIT when desired flag status is displayed.

During normal operation, pressing the "CE" key will cause raw signal readout to be displayed for 5 seconds.

Page 43

Image 42
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Four Component Software Part Troubleshooting / SoftwarePart Hardware Maintenance Part OperationSpecial Features Assembly InstructionsCheck OUT Procedure Proceed to Safety Hazards NextProceed to Assembly Next Safety Hazards MIX BladesSafety Features Safety Interlock Switch Additional MIX Blade HazardDisclaimers Please Be Careful Part AssemblyLoad Cells are Easily Damaged On the NextPage Wiring Considerations Proceed to Check OUT Procedure NextAT this Point Procedure What should Happen Plug in ControllerTurn Power on Touch Weigh BIN Very LightlyLED # Press Alarm KEYPress REG KEY Press NAT KEYPage Password ExitCAL OFF Part Operation Load Cell CalibrationBe Sure CALOperate Proceed to Normal Operation NextOper COLGB/WSB MB Selected Models Special InstructionsMicro Pulse GB/WSB 240RPower on If Problems DevelopPower OFF Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind Eight Character Display ROM OKAlarm Silence Right Column AlarmsStrobe Light and Beeper Alarms LED LightsMixer Motor ON/OFF/TIMED Switch Mixer Motor OutletMixer Motor Fuse Internal Fuses KeypadDate RUN Keypad Automatic Operation ModeRecipe RCPSave BtchTABLE, FLG Page Fast TAGKeypad Manual Mode ALLTimed Time ADDPage Keypad Program Mode Para Star FunctionsYLD Ctrl Page Page Page Page Page Page Page Page Parameters Parameter List Brief ExplanationsMIX Time XXX RLO Page CPL Full Explanation of Parameters No ALARM, no Retries MPOMIX KDF / WDF BERPage ROV Page Example RHL is Set 10 percent Page Setting SETPage Page Page Page Page XCV + XRC TCV + TRCXTP XAL XULPTD LIQMCT Page APO Parameter Default Settings Four SoftwareFLG RPO NPO CPO MPO RAL NAL CAL AAL MIX JOGNWT NPT CPT APT RWTRTI NTIChanging Parameters REG Natural COL Prnt OFFPrnt TotalFinal DISP,% What to Check for Page Page Page Time Natural Special TestsTime Calibrate NaturalDate Time Totals Grand PCT Current Material Usage InformationPARAMETER, PRT Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function Load Cell RAW Signal Readout CNT OFFCNT Results to Expect Clear Routine Clear ALL RestartCore Dump Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Wait Recalibration of Load CellsZero FullLoad Cells Blender Preventive MaintenanceDispense Gates Weigh BinsThese Instructions for Totalizers only Blender Special Totalizer FunctionStop END of Cycle TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Specifications Gravimetric Batch Blenders Autoweigh GBM Series ModelsGravimetric Batch Blenders AutoWeigh GB100 Series Models TOP View Front View Side View120V/1 phase/50-60 Hz 240V/1 phase/50-60 Hz Gravimetric Batch Blenders GB 220 and 420 ModelsGravimetric Batch Blenders AutoWeigh GB240 and GB440 Models TOP View Mounting InterfaceGravimetric Batch Blenders AutoWeigh GB900 Series Models 2124Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 Models GB1840 GB1860Gravimetric Batch Blenders Wsbm Series models Control Remote Mounted Models WSBM22 WSBM131 WSBM140Gravimetric Batch Blenders WSB 100 and 100R Models Side View Front View Side View, R Model Front View, R ModelGravimetric Batch Blenders WSB 220 and 420 Models 24.4Gravimetric Batch Blenders WSB 240/440 and 240/440R Models WSB442Gravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C