Conair GB/ WSB manual Gravimetric Batch Blenders Wsbm Series models

Page 105

SPECIFICATIONS

TPBS016/0700

GRAVIMETRIC BATCH BLENDERS WSBM Series models

B

A

CONTROL (REMOTE MOUNTED)

MODELS

WSBM22

WSBM131

WSBM140

Performance characteristics

 

 

 

Batch size lbs {g}

0.882 {400}

0.882 {400}

0.882 {400}

Maximum throughput lbs/hr {kg/hr}*

97 {44}

111 {50}

132 {60}

Bin capacity - standard bins ft3 {liter}

0.4 {5.7}

0.4 {5.7}

0.4 {5.7}

Maximum number of materials

4

4

4

Number of standard dispensing valves

2

3

4

Number of micro dispensing valves

2

1

0

Control software (# of components)

4 or 12

4 or 12

4 or 12

Dimensions inches {mm}

 

 

 

A - Height above mounting plate

27.25 {693}

27.25 {693}

27.25 {693}

B - Width

21.75 {552.4}

21.75 {552.4}

21.75 {552.4}

C - Depth

21.75 {552.4}

21.75 {552.4}

21.75 {552.4}

D - Controller height

11.25 {285.75}

11.25 {285.75}

11.25 {285.75}

E - Controller width

12.25 {311.15}

12.25 {311.15}

12.25 {311.15}

F - Controller depth

8.19 {208.03}

8.19 {208.03}

8.19 {208.03}

Weight lbs {kg}

 

 

 

Installed

60 {27}

60 {27}

60 {27}

Shipping

80 {36.3}

80 {36.3}

80 {36.3}

Voltage Running load amps

 

 

 

120V/1 phase 50/60 hz

1.0

1.0

1.0

220V/1 phase 50/60 hz

0.5

0.5

0.5

Compressed air requirements

 

 

 

 

40 psi @ 1 ft3/min { bars @ 0.47 liters/sec}

 

 

1/4 in. NPT fitting

 

Material filling options

 

 

 

Self-contained vacuum loader

 

ML8

 

Central vacuum receiver

 

DL8

 

Hand-fill

 

flat lid

 

 

 

 

 

MOUNTING INTERFACE

SPECIFICATION NOTES:

*Maximum throughput rates are based on using all dispense valves dispensing no more than 1.0% colorant or additive per each micropulsing valve. Refer to the selection guide for more specific throughput informa- tion.

APPLICATION NOTE:

Handfill unless otherwise specified.

If you will be using this blender for central blending applications, it will be necessary to use a flow control valve with an air solenoid.

One Conair Drive Pittsburgh, PA 15202 412-312-6000 FAX 412-312-6227 www.conairnet.com

APPENDIX B

Image 105
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Part Hardware Maintenance Part Troubleshooting / SoftwareFour Component Software Part OperationCheck OUT Procedure Assembly InstructionsSpecial Features Proceed to Safety Hazards NextSafety Features Safety Interlock Switch Safety Hazards MIX BladesProceed to Assembly Next Additional MIX Blade HazardDisclaimers Load Cells are Easily Damaged Part AssemblyPlease Be Careful On the NextPage Proceed to Check OUT Procedure Next Wiring ConsiderationsTurn Power on Procedure What should Happen Plug in ControllerAT this Point Touch Weigh BIN Very LightlyPress REG KEY Press Alarm KEYLED # Press NAT KEYPage Exit PasswordBe Sure Part Operation Load Cell CalibrationCAL OFF CALOper Proceed to Normal Operation NextOperate COLMicro Pulse Selected Models Special InstructionsGB/WSB MB GB/WSB 240RPower OFF If Problems DevelopPower on Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind ROM OK Eight Character DisplayStrobe Light and Beeper Alarms Right Column AlarmsAlarm Silence LED LightsMixer Motor ON/OFF/TIMED Switch Mixer Motor OutletMixer Motor Fuse Keypad Internal FusesDate Recipe Keypad Automatic Operation ModeRUN RCPSave BtchTABLE, FLG Page TAG FastALL Keypad Manual ModeTime ADD TimedPage Keypad Program Mode Para Star FunctionsYLD Ctrl Page Page Page Page Page Page Page Page Parameters Parameter List Brief ExplanationsMIX Time XXX RLO Page CPL Full Explanation of Parameters MPO No ALARM, no RetriesMIX BER KDF / WDFPage ROV Page Example RHL is Set 10 percent Page SET SettingPage Page Page Page Page XCV + XRC TCV + TRCXTP XUL XALPTD LIQMCT Page FLG RPO NPO CPO Parameter Default Settings Four SoftwareAPO MPO RAL NAL CAL AAL MIX JOGRTI NPT CPT APT RWTNWT NTIChanging Parameters Prnt Prnt OFFREG Natural COL TotalFinal DISP,% What to Check for Page Page Page Time Special TestsTime Natural Calibrate NaturalPARAMETER, PRT Material Usage InformationDate Time Totals Grand PCT Current Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function Load Cell RAW Signal Readout CNT OFFCNT Results to Expect Clear Routine Clear ALL RestartCore Dump Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Zero Recalibration of Load CellsWait FullDispense Gates Blender Preventive MaintenanceLoad Cells Weigh BinsThese Instructions for Totalizers only Stop END of Cycle Special Totalizer FunctionBlender TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Gravimetric Batch Blenders Autoweigh GBM Series Models SpecificationsTOP View Front View Side View Gravimetric Batch Blenders AutoWeigh GB100 Series ModelsGravimetric Batch Blenders GB 220 and 420 Models 120V/1 phase/50-60 Hz 240V/1 phase/50-60 HzTOP View Mounting Interface Gravimetric Batch Blenders AutoWeigh GB240 and GB440 Models2124 Gravimetric Batch Blenders AutoWeigh GB900 Series ModelsGB1840 GB1860 Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 ModelsControl Remote Mounted Models WSBM22 WSBM131 WSBM140 Gravimetric Batch Blenders Wsbm Series modelsSide View Front View Side View, R Model Front View, R Model Gravimetric Batch Blenders WSB 100 and 100R Models24.4 Gravimetric Batch Blenders WSB 220 and 420 ModelsWSB442 Gravimetric Batch Blenders WSB 240/440 and 240/440R ModelsGravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C