Conair GB/ WSB manual Setting

Page 57

_SE (This might be useful)

_SE is the upper SETTING limits for the thumbwheel switches. This allows a reasonable cap to be set for each component so that an operator cannot accidentally set the controls to an excessively high setting. For color and additive, these limits will ensure that expensive material is not wasted. Thumbwheel settings that are greater than the limit are held to the limit.

EXAMPLE: If the highest color usage in your plant is 6%, you may enter this upper limit in the parameter table. Since settings are stored as 1/10s of percent (##.#), the parameter would be:

CSE 00060

Color thumbwheel settings above 060 will be held to 6 percent.

NOTE: If

you wish to positively fix the settings so that the

thumbwheel

switches have no control

and no one can change them without

authorization,

you may do this by using the KEYPAD to enter any or

all

settings.

To do so:

 

 

 

 

 

+---------------------------------------------------

 

 

 

+

 

¦ Press:

*

Display will say:

(PASSWORD)

¦

 

¦ Press:

22222

Display will say:

(P

x)

¦

 

¦ Press:

SET

Display will say:

(SETTING )

¦

 

¦ Press:

COL (or ADD or REG)

 

 

¦

 

¦

 

Display will say:

(C = xx.x)

¦

 

¦ Enter:

New setting

 

 

¦

 

¦

 

 

 

 

¦

 

¦ Press:

EXIT

Display will say:

(P

xxxxx)

¦

 

+---------------------------------------------------

 

 

 

+

An LED will light indicating this override condition. This occurs only when the thumbwheel does not match the internal setting.

To later return to thumbwheel control, use the same procedure as above except instead of entering a setting, press the "CE" key when you see the setting displayed.

The operator may still prevent running this component by entering a setting of all ZEROS (00.0). This will override any setting entered by the keypad. If you do not want this override option, enter a 1 as the first digit in the SE parameter. (_SE 1xxxx)

======================================================================

RLO (probably no need to ever change this)

RLO is the lower limit for SETTING the regrind thumbwheel switches. Settings lower than this number will be held to the low limit. Air operated dump valves are not intended to dispense very small quantities. We have set RLO at the factory to 5 percent (00050) allowing a minimum dispense of 5% or about 100 grams.

======================================================================

DLY (consider changing if mixing is a problem)

DLY is the TIME the mix chamber level sensor must be uncovered before a cycle begins. The sensor must be uncovered without

Page 58

Image 57
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Part Hardware Maintenance Part Troubleshooting / SoftwareFour Component Software Part OperationCheck OUT Procedure Assembly InstructionsSpecial Features Proceed to Safety Hazards NextSafety Features Safety Interlock Switch Safety Hazards MIX BladesProceed to Assembly Next Additional MIX Blade HazardDisclaimers Load Cells are Easily Damaged Part AssemblyPlease Be Careful On the NextPage Proceed to Check OUT Procedure Next Wiring ConsiderationsTurn Power on Procedure What should Happen Plug in ControllerAT this Point Touch Weigh BIN Very LightlyPress REG KEY Press Alarm KEYLED # Press NAT KEYPage Exit PasswordBe Sure Part Operation Load Cell CalibrationCAL OFF CALOper Proceed to Normal Operation NextOperate COLMicro Pulse Selected Models Special InstructionsGB/WSB MB GB/WSB 240RPower OFF If Problems DevelopPower on Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind ROM OK Eight Character DisplayStrobe Light and Beeper Alarms Right Column AlarmsAlarm Silence LED LightsMixer Motor ON/OFF/TIMED Switch Mixer Motor OutletMixer Motor Fuse Keypad Internal FusesDate Recipe Keypad Automatic Operation ModeRUN RCPSave BtchTABLE, FLG Page TAG FastALL Keypad Manual ModeTime ADD TimedPage Keypad Program Mode Para Star FunctionsYLD Ctrl Page Page Page Page Page Page Page Page Parameters Parameter List Brief ExplanationsMIX Time XXX RLO Page CPL Full Explanation of Parameters MPO No ALARM, no RetriesMIX BER KDF / WDFPage ROV Page Example RHL is Set 10 percent Page SET SettingPage Page Page Page Page XCV + XRC TCV + TRCXTP XUL XALPTD LIQMCT Page FLG RPO NPO CPO Parameter Default Settings Four SoftwareAPO MPO RAL NAL CAL AAL MIX JOGRTI NPT CPT APT RWTNWT NTIChanging Parameters Prnt Prnt OFFREG Natural COL TotalFinal DISP,% What to Check for Page Page Page Time Special TestsTime Natural Calibrate NaturalPARAMETER, PRT Material Usage InformationDate Time Totals Grand PCT Current Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function Load Cell RAW Signal Readout CNT OFFCNT Results to Expect Clear Routine Clear ALL RestartCore Dump Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Zero Recalibration of Load CellsWait FullDispense Gates Blender Preventive MaintenanceLoad Cells Weigh BinsThese Instructions for Totalizers only Stop END of Cycle Special Totalizer FunctionBlender TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Gravimetric Batch Blenders Autoweigh GBM Series Models SpecificationsTOP View Front View Side View Gravimetric Batch Blenders AutoWeigh GB100 Series ModelsGravimetric Batch Blenders GB 220 and 420 Models 120V/1 phase/50-60 Hz 240V/1 phase/50-60 HzTOP View Mounting Interface Gravimetric Batch Blenders AutoWeigh GB240 and GB440 Models2124 Gravimetric Batch Blenders AutoWeigh GB900 Series ModelsGB1840 GB1860 Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 ModelsControl Remote Mounted Models WSBM22 WSBM131 WSBM140 Gravimetric Batch Blenders Wsbm Series modelsSide View Front View Side View, R Model Front View, R Model Gravimetric Batch Blenders WSB 100 and 100R Models24.4 Gravimetric Batch Blenders WSB 220 and 420 ModelsWSB442 Gravimetric Batch Blenders WSB 240/440 and 240/440R ModelsGravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C