Conair GB/ WSB manual LED Lights, Left Column, Right Column Alarms, Strobe Light and Beeper Alarms

Page 22

10.LED LIGHTS

The LED lights in two vertical columns of eight located above the 8 character display indicate the following:

LEFT COLUMN:

1.REG Regrind dump solenoid operating.

2.NAT Natural dump solenoid operating.

3.COL Color drive relay operating.

4.ADD Additive drive relay operating.

5.DMP Dump valve solenoid operating.

6.ALM Alarm output operating.

7.MIX Mixer motor drive relay operating.

8.HLD Mixer flow valve is open (Optional).

RIGHT COLUMN:

ALARMS

1.Alarm is on because Regrind ran out.

2.Alarm is on because Natural ran out.

3.Alarm is on because Color ran out.

4.Alarm is on because Additive ran out.

5.Alarm is on because Weigh bin is not within limits.

6.C Color thumbwheel switches are locked out and the setting being used does not match the thumbwheel setting.

7.A Additive thumbwheel switches are locked out and the setting being used does not match the thumbwheel setting.

8.R Regrind thumbwheel switches are locked out and the setting being used does not match the thumbwheel setting.

11.STROBE LIGHT AND BEEPER ALARMS

The Strobe light flashes and the Beeper sounds when NATURAL, COLOR, or ADDITIVE fail to meter properly. Alarms begin after a preset number of retries have occurred. The number of retries before Alarm is determined by settings in the parameter table (see parameters _AL). Regrind can also be alarmed.

12.ALARM SILENCE

This button stops the STROBE and BEEPER ALARMS. The continuation of the cycle to its proper completion will also stop the alarm.

If the BATCH mode is in operation, this button starts the next batch.

13.LEVEL SENSOR input

The high level sensor in the mixing chamber plugs into this outlet and signals the controller to start a dispense cycle when it is uncovered. The sensor must be uncovered for at least 2 seconds before a cycle will start. (see DLY 00488) parameter). Once a dispense cycle is started, covering the sensor does not stop it. Operation continues until the cycle is complete.

Page 23

Image 22
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Four Component Software Part Troubleshooting / SoftwarePart Hardware Maintenance Part OperationSpecial Features Assembly InstructionsCheck OUT Procedure Proceed to Safety Hazards NextProceed to Assembly Next Safety Hazards MIX BladesSafety Features Safety Interlock Switch Additional MIX Blade HazardDisclaimers Please Be Careful Part AssemblyLoad Cells are Easily Damaged On the NextPage Wiring Considerations Proceed to Check OUT Procedure NextAT this Point Procedure What should Happen Plug in ControllerTurn Power on Touch Weigh BIN Very LightlyLED # Press Alarm KEYPress REG KEY Press NAT KEYPage Password ExitCAL OFF Part Operation Load Cell CalibrationBe Sure CALOperate Proceed to Normal Operation NextOper COLGB/WSB MB Selected Models Special InstructionsMicro Pulse GB/WSB 240RPower on If Problems DevelopPower OFF Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind Eight Character Display ROM OKAlarm Silence Right Column AlarmsStrobe Light and Beeper Alarms LED LightsMixer Motor Outlet Mixer Motor ON/OFF/TIMED SwitchMixer Motor Fuse Internal Fuses KeypadDate RUN Keypad Automatic Operation ModeRecipe RCPBtch SaveTABLE, FLG Page Fast TAGKeypad Manual Mode ALLTimed Time ADDPage Keypad Program Mode Star Functions ParaYLD Ctrl Page Page Page Page Page Page Page Page Parameter List Brief Explanations ParametersMIX Time XXX RLO Page CPL Full Explanation of Parameters No ALARM, no Retries MPOMIX KDF / WDF BERPage ROV Page Example RHL is Set 10 percent Page Setting SETPage Page Page Page Page TCV + TRC XCV + XRCXTP XAL XULLIQ PTDMCT Page APO Parameter Default Settings Four SoftwareFLG RPO NPO CPO MPO RAL NAL CAL AAL MIX JOGNWT NPT CPT APT RWTRTI NTIChanging Parameters REG Natural COL Prnt OFFPrnt TotalFinal DISP,% What to Check for Page Page Page Time Natural Special TestsTime Calibrate NaturalDate Time Totals Grand PCT Current Material Usage InformationPARAMETER, PRT Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function CNT OFF Load Cell RAW Signal ReadoutCNT Results to Expect Clear ALL Restart Clear RoutineCore Dump Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Wait Recalibration of Load CellsZero FullLoad Cells Blender Preventive MaintenanceDispense Gates Weigh BinsThese Instructions for Totalizers only Blender Special Totalizer FunctionStop END of Cycle TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Specifications Gravimetric Batch Blenders Autoweigh GBM Series ModelsGravimetric Batch Blenders AutoWeigh GB100 Series Models TOP View Front View Side View120V/1 phase/50-60 Hz 240V/1 phase/50-60 Hz Gravimetric Batch Blenders GB 220 and 420 ModelsGravimetric Batch Blenders AutoWeigh GB240 and GB440 Models TOP View Mounting InterfaceGravimetric Batch Blenders AutoWeigh GB900 Series Models 2124Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 Models GB1840 GB1860Gravimetric Batch Blenders Wsbm Series models Control Remote Mounted Models WSBM22 WSBM131 WSBM140Gravimetric Batch Blenders WSB 100 and 100R Models Side View Front View Side View, R Model Front View, R ModelGravimetric Batch Blenders WSB 220 and 420 Models 24.4Gravimetric Batch Blenders WSB 240/440 and 240/440R Models WSB442Gravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C