NOTE: Fractional cycles are not blended. Total weight may be in over the target by as much as one cycle weight.
The EXIT key will exit the BTCH sequence at any point but will NOT cause the system to start a new batch.
If an additional 120 volt output is desired for an alarm, substitute a 4 or 7 for the 00001. 4 turns on the Additive outlet, 7 turns on component 7 output.
If you have a printer connected, totals will print automatically. (see VIEW, * for details).
FAST: | This key | will | allow | you | to exceed the | normal blending rate | |
| of your unit. | Once | your system has learned proper flow | ||||
| rates of | each | material, | the timing of | each component | ||
| dispense | is very consistent cycle to cycle. The FAST key | |||||
| allows one or | more | FAST | REPEAT cycles | to follow a normal | ||
| calibrated cycle. | In a | FAST REPEAT cycle all components are | ||||
| dispensed simultaneously, without any | weights being taken. | |||||
| Errors in dispense amounts will not be detected. These are, | ||||||
| in fact, | volumetric | dispenses, not gravimetric. These | ||||
| dispenses take much | less time. Throughput may be doubled in | |||||
| this manner. |
|
|
|
|
|
This key is NOT FUNCTIONAL unless the 4th digit of the "FLG" parameter is set to 1 (xxx1x). To do this, see the SOFTWARE MAINTENANCE section, PARAMETER TABLE, "FLG".
The shorter mixing time may be a problem. So the number of FAST REPEAT cycles is kept as low as possible. Up to 4 repeats may occur.
After pressing the FAST key, use the * key to toggle the FAST flag ON of OFF. When set to (FAST OFF) FAST mode will not operate. When set (FAST ON) every normal calibrated dispense will be followed by up to 4 FAST repeat dispenses.
Press * to toggle between (FAST ON) and (FAST OFF).
Press EXIT, to exit.
When the FAST mode is in operation, the display ( FAST) will flash intermittently.
TAG: | This key (third row, | third key) | allows three pieces of | |
| information to be "tagged" onto | all data that is | either | |
| printed or retrieved | through the computer port. | The items | |
| are WORK ORDER, OPERATOR, and RECIPE number. |
|
This key is NOT FUNCTIONAL unless the 2nd digit of the "FLG" parameter is set to 1 (x1xxx). To do this, see the SOFTWARE MAINTENANCE section, PARAMETER TABLE, "FLG".
Press once to display the current Work Order number
number
Page 30