RMI 00001 Minimum valid dump rate GRAMS/sec. (full or tenth grams)

NMI 00001 Error correction is bypassed when dispense rate is lower. CMI 00001

AMI 00001

On power up, these are always set to 1. After several consistent cycles, they are reset to 80 percent of actual flow rate. These prevent excessive swings in flow rate calculations if material is running out.

RNC 00050 Allowable GRAM error within which NO correction is made. NNC 00050

CNC 00010

ANC 00010

This is the acceptable error range for each component to prevent hunting. They adjust automatically over an extended time period to match the flow characteristics of each material.

RRP 00010 PERCENT shortage error that will force a retry. NRP 00010

CRP 00010

ARP 00010

RRD 00500 GRAM weight shortage error that will force a retry. NRD 00500

CRD 00050

ARD 00050

Both RP and RD limits must be met before system will advance to the next component. Retries occur until both conditions are met.

RLA 00020 Lag TIME before dumping ACTUALLY starts.

NLA 00020 (mechanical response time, interrupts)

CLA 00012

ALA 00012

These parameters state the lag time between when a device is signaled and when it actually begins to operate.

Change ONLY if you change to non-standard equipment.

PRC 00010 Maximum allowable PERCENT rate change per cycle.

This prevents excessive swings in flow rates. Do not change.

STL 00244 Dispense settle TIME before a weight reading is taken.

The time (interrupts) allowed for material to SETTLE in the weigh bin before a weight is taken. Lengthen only to slow the next cycle start, thereby lowering the pile of material in the mix chamber, and, in some cases, improving mixing.

LCL 00027 LOAD CELL limits, low slope, high slope, frequency, zero.

LCH 00039 DO NOT CHANGE except for different weight load cells. LCF 00079

LCZ 00583

These parameters relate to the characteristics of the LOAD CELLS on your blender. DO NOT CHANGE THEM.

Page 47

Image 46
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Four Component Software Part Troubleshooting / SoftwarePart Hardware Maintenance Part OperationSpecial Features Assembly InstructionsCheck OUT Procedure Proceed to Safety Hazards NextProceed to Assembly Next Safety Hazards MIX BladesSafety Features Safety Interlock Switch Additional MIX Blade HazardDisclaimers Please Be Careful Part AssemblyLoad Cells are Easily Damaged On the NextPage Wiring Considerations Proceed to Check OUT Procedure NextAT this Point Procedure What should Happen Plug in ControllerTurn Power on Touch Weigh BIN Very LightlyLED # Press Alarm KEYPress REG KEY Press NAT KEYPage Password ExitCAL OFF Part Operation Load Cell CalibrationBe Sure CALOperate Proceed to Normal Operation NextOper COLGB/WSB MB Selected Models Special InstructionsMicro Pulse GB/WSB 240RPower on If Problems DevelopPower OFF Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind Eight Character Display ROM OKAlarm Silence Right Column AlarmsStrobe Light and Beeper Alarms LED LightsMixer Motor Outlet Mixer Motor ON/OFF/TIMED SwitchMixer Motor Fuse Internal Fuses KeypadDate RUN Keypad Automatic Operation ModeRecipe RCPBtch SaveTABLE, FLG Page Fast TAGKeypad Manual Mode ALLTimed Time ADDPage Keypad Program Mode Star Functions ParaYLD Ctrl Page Page Page Page Page Page Page Page Parameter List Brief Explanations ParametersMIX Time XXX RLO Page CPL Full Explanation of Parameters No ALARM, no Retries MPOMIX KDF / WDF BERPage ROV Page Example RHL is Set 10 percent Page Setting SETPage Page Page Page Page TCV + TRC XCV + XRCXTP XAL XULLIQ PTDMCT Page APO Parameter Default Settings Four SoftwareFLG RPO NPO CPO MPO RAL NAL CAL AAL MIX JOGNWT NPT CPT APT RWTRTI NTIChanging Parameters REG Natural COL Prnt OFFPrnt TotalFinal DISP,% What to Check for Page Page Page Time Natural Special TestsTime Calibrate NaturalDate Time Totals Grand PCT Current Material Usage InformationPARAMETER, PRT Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function CNT OFF Load Cell RAW Signal ReadoutCNT Results to Expect Clear ALL Restart Clear RoutineCore Dump Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Wait Recalibration of Load CellsZero FullLoad Cells Blender Preventive MaintenanceDispense Gates Weigh BinsThese Instructions for Totalizers only Blender Special Totalizer FunctionStop END of Cycle TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Specifications Gravimetric Batch Blenders Autoweigh GBM Series ModelsGravimetric Batch Blenders AutoWeigh GB100 Series Models TOP View Front View Side View120V/1 phase/50-60 Hz 240V/1 phase/50-60 Hz Gravimetric Batch Blenders GB 220 and 420 ModelsGravimetric Batch Blenders AutoWeigh GB240 and GB440 Models TOP View Mounting InterfaceGravimetric Batch Blenders AutoWeigh GB900 Series Models 2124Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 Models GB1840 GB1860Gravimetric Batch Blenders Wsbm Series models Control Remote Mounted Models WSBM22 WSBM131 WSBM140Gravimetric Batch Blenders WSB 100 and 100R Models Side View Front View Side View, R Model Front View, R ModelGravimetric Batch Blenders WSB 220 and 420 Models 24.4Gravimetric Batch Blenders WSB 240/440 and 240/440R Models WSB442Gravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C