RATE CALIBRATION
RATE CALIBRATION is probably not necessary. The software initially expects STANDARD hardware. However, if you are using an auger feeder on a model with four dispense valves, or a 1/2 inch auger instead of a 1" auger, the software will take 10 or 20 cycles to adjust to correct operation. This slows down the process for a short time, but does not effect accuracy.
If your hardware is STANDARD, or |
| |
you prefer letting the system SELF ADJUST, |
| |
you may: |
|
|
+ | ||
¦ |
| ¦ |
¦ PROCEED TO: | NORMAL OPERATION | NEXT PAGE ¦ |
¦ |
| ¦ |
+ |
To perform a RATE CALIBRATION:
Have all HOPPERS LOADED with enough material to run for several cycles without running out.
Have the "OFF AT END OF CYCLE" and "PAUSE" switches DOWN.
Press: | * | Display | will | say: | (PASSWORD) | |
Press: | 22222 | Display | will | say: | (P | x) |
If your system has auger feeders, operate them briefly to ensure they are fully primed. To do so:
Press: | OPER | Display will say: | (OPERATE ) | |||
Press: | COL | Run | until auger is dispensing. | |||
Press: | ADD | Run | until | auger | is dispensing. | |
Press: | DUMP | This will | empty | the | weigh bin. |
Now you can CALIBRATE EACH material.
To do so:
Press: | CAL | Display | will | say: | (CALIBRATE) |
Press: | REG | REGRIND | will | calibrate itself. |
For each material, press CAL followed by the proper component key. Each time a dispense will occur, followed by weighing, followed by a dump to empty the weigh bin.
Press: | EXIT | when all calibrations are done. |
|
| |
YOU ARE NOW READY FOR ACCURATE PRODUCTION BLENDING. |
| ||||
|
|
| + | ||
| ¦ |
|
|
| ¦ |