Conair GB/ WSB manual Cpl

Page 47

SCR 00000 Special Customer Request function to be activated.

BCR 00000 For BAR CODE input equipped blenders.

The following parameters are all related to EXTRUSION CONTROL only.

XTP 05050 Extrusion Control - TRIP POINT for a Rate adjustment.

As batch timing errors accumulate, this number determines how large the accumulated error must be to force an adjustment.

XCV 00000 Extrusion Control - Extruder speed Control Voltage.

XRC 00004 Extrusion Control - Extruder speed Rate of Change.

These two paremeters control the voltage output to the extruder speed control, and its rate of change.

TCV 00000 Extrusion Control - Takeoff speed control voltage.

TRC 00004 Extrusion Control - Takeoff speed Rate of Change.

These two paremeters control the voltage output to the downstream takeoff speed control, and its rate of change.

XAL 00005 Extrusion Control - Single Adjustment Limit, percent.

Single rate adjustments are limited to this percentage change.

XUL 00200 Extrusion Control - Upper Adjustment Limit, volts

Adjustments beyond this voltage change will sound the alarm.

CPL

Yield Control - Counts per unit Length.

Matches your down stream takeoff speed encoder to the software.

PTD 00020 Yield Control - Pulse Train Delta

Allows slight errors in encoder pulse train pulse rate

LIQ 00000 For LIQUID COLOR applications using dual pumps.

Allows automatic switching when current container runs out.

MCT 00000 Monitor Cycle Time

Alarms if normal cycle timing exceeds previous cycle time by a specified amount. Used to detect mechanical failures.

Page 48

Image 47
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Part Operation Part Troubleshooting / SoftwarePart Hardware Maintenance Four Component SoftwareProceed to Safety Hazards Next Assembly InstructionsCheck OUT Procedure Special FeaturesAdditional MIX Blade Hazard Safety Hazards MIX BladesSafety Features Safety Interlock Switch Proceed to Assembly NextDisclaimers On the Next Part AssemblyLoad Cells are Easily Damaged Please Be CarefulPage Proceed to Check OUT Procedure Next Wiring ConsiderationsTouch Weigh BIN Very Lightly Procedure What should Happen Plug in ControllerTurn Power on AT this PointPress NAT KEY Press Alarm KEYPress REG KEY LED #Page Exit PasswordCAL Part Operation Load Cell CalibrationBe Sure CAL OFFCOL Proceed to Normal Operation NextOper OperateGB/WSB 240R Selected Models Special InstructionsMicro Pulse GB/WSB MBInstructions for Normal Operation If Problems DevelopPower OFF Power onNormal Operating Sequence Each Cycle Exit Regrind ROM OK Eight Character DisplayLED Lights Right Column AlarmsStrobe Light and Beeper Alarms Alarm SilenceMixer Motor Fuse Mixer Motor ON/OFF/TIMED SwitchMixer Motor Outlet Keypad Internal FusesDate RCP Keypad Automatic Operation ModeRecipe RUNTABLE, FLG SaveBtch Page TAG FastALL Keypad Manual ModeTime ADD TimedPage Keypad Program Mode YLD Ctrl ParaStar Functions Page Page Page Page Page Page Page Page MIX Time ParametersParameter List Brief Explanations XXX RLO Page CPL Full Explanation of Parameters MPO No ALARM, no RetriesMIX BER KDF / WDFPage ROV Page Example RHL is Set 10 percent Page SET SettingPage Page Page Page Page XTP XCV + XRCTCV + TRC XUL XALMCT PTDLIQ Page MPO RAL NAL CAL AAL MIX JOG Parameter Default Settings Four SoftwareFLG RPO NPO CPO APONTI NPT CPT APT RWTRTI NWTChanging Parameters Total Prnt OFFPrnt REG Natural COLFinal DISP,% What to Check for Page Page Page Calibrate Natural Special TestsTime Time NaturalCycles Last Printed 11/01/90 Material Usage InformationPARAMETER, PRT Date Time Totals Grand PCT CurrentPart IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function CNT Load Cell RAW Signal ReadoutCNT OFF Results to Expect Core Dump Clear RoutineClear ALL Restart Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Full Recalibration of Load CellsZero WaitWeigh Bins Blender Preventive MaintenanceDispense Gates Load CellsThese Instructions for Totalizers only Totalize Special Totalizer FunctionStop END of Cycle BlenderComputer Outputs Wiring Supplement Call Appendix A-2 Gravimetric Batch Blenders Autoweigh GBM Series Models SpecificationsTOP View Front View Side View Gravimetric Batch Blenders AutoWeigh GB100 Series ModelsGravimetric Batch Blenders GB 220 and 420 Models 120V/1 phase/50-60 Hz 240V/1 phase/50-60 HzTOP View Mounting Interface Gravimetric Batch Blenders AutoWeigh GB240 and GB440 Models2124 Gravimetric Batch Blenders AutoWeigh GB900 Series ModelsGB1840 GB1860 Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 ModelsControl Remote Mounted Models WSBM22 WSBM131 WSBM140 Gravimetric Batch Blenders Wsbm Series modelsSide View Front View Side View, R Model Front View, R Model Gravimetric Batch Blenders WSB 100 and 100R Models24.4 Gravimetric Batch Blenders WSB 220 and 420 ModelsWSB442 Gravimetric Batch Blenders WSB 240/440 and 240/440R ModelsGravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C