Conair GB/ WSB manual Parameters, Parameter List Brief Explanations, MIX Time

Page 43

PARAMETERS

All WEIGH SCALE BLENDER controllers operate according to certain internal PARAMETERS. Because customer requirements vary widely, we have made over 60 parameters accessible for change through the keypad.

BRIEF explanations are given first. FULL information is given in the section that follows.

NOTE: Values shown here are initial ROM values of a model 220. Initial values for other models are listed at the end of this section.

Parameters are five digits, with leading zeros added.

TIMES are expressed as seconds, minutes, or interrupts. (244 interrupts = 1 second).

WEIGHTS are always expressed as GRAMS.

100 and 200 models use tenths of grams: (xxxx.x). (00010 = 1 gram)

400, 900, and 1800 models; full grams: (xxxxx). (00050 = 50 grams)

PERCENTS are expressed in tenths for settings (0xxx.x),

and full percents for other percentage references (00xxx).

======================================================================

PARAMETER LIST - BRIEF EXPLANATIONS

FLG 00000 turns on the RECIPE, BATCH, FAST, and TAG keys.

These four keys will NOT WORK unless you set this parameter.

The

RECIPE key is for

storing up to 99 recipes.

The

BATCH key allows for filling a barrel or gaylord.

The

FAST key

allows a

higher output mode.

The

TAG key adds certain information to all printouts.

RPO 00000

Pulsed Output,

timing of ON/OFF pulses.

NPO 00000

(Reg,

Nat, Col, Add).

CPO 00000

Set only for Micro Pulse equipped slide gates.

APO 00000

 

 

 

MPO 00010

Pulsed output to the mixer motor

RAL 00000

Last digit = number of retries before ALARM.

NAL 00004

00001

to 00009

= sound alarm, hold process.

CAL 00004

00011

to 00019

= sound alarm, continue process.

AAL 00004

00000

= no alarm, no retries.

These parameters set ALARM

functions.

 

 

When material runs out,

or

does

not

dispense

fully, these flags

instruct the

controller

what to

do.

Default

settings shown

are

for

Natural,

Color, and

Additive to

alarm, but not Regrind.

 

MIX 00015

MIX TIME

 

 

 

 

 

 

This parameter times how long the MIX motor runs in seconds.

Page 44

Image 43
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Part Operation Part Troubleshooting / SoftwarePart Hardware Maintenance Four Component SoftwareProceed to Safety Hazards Next Assembly InstructionsCheck OUT Procedure Special FeaturesAdditional MIX Blade Hazard Safety Hazards MIX BladesSafety Features Safety Interlock Switch Proceed to Assembly NextDisclaimers On the Next Part AssemblyLoad Cells are Easily Damaged Please Be CarefulPage Proceed to Check OUT Procedure Next Wiring ConsiderationsTouch Weigh BIN Very Lightly Procedure What should Happen Plug in ControllerTurn Power on AT this PointPress NAT KEY Press Alarm KEYPress REG KEY LED #Page Exit PasswordCAL Part Operation Load Cell CalibrationBe Sure CAL OFFCOL Proceed to Normal Operation NextOper OperateGB/WSB 240R Selected Models Special InstructionsMicro Pulse GB/WSB MBInstructions for Normal Operation If Problems DevelopPower OFF Power onNormal Operating Sequence Each Cycle Exit Regrind ROM OK Eight Character DisplayLED Lights Right Column AlarmsStrobe Light and Beeper Alarms Alarm SilenceMixer Motor Outlet Mixer Motor ON/OFF/TIMED SwitchMixer Motor Fuse Keypad Internal FusesDate RCP Keypad Automatic Operation ModeRecipe RUNBtch SaveTABLE, FLG Page TAG FastALL Keypad Manual ModeTime ADD TimedPage Keypad Program Mode Star Functions ParaYLD Ctrl Page Page Page Page Page Page Page Page Parameter List Brief Explanations ParametersMIX Time XXX RLO Page CPL Full Explanation of Parameters MPO No ALARM, no RetriesMIX BER KDF / WDFPage ROV Page Example RHL is Set 10 percent Page SET SettingPage Page Page Page Page TCV + TRC XCV + XRCXTP XUL XALLIQ PTDMCT Page MPO RAL NAL CAL AAL MIX JOG Parameter Default Settings Four SoftwareFLG RPO NPO CPO APONTI NPT CPT APT RWTRTI NWTChanging Parameters Total Prnt OFFPrnt REG Natural COLFinal DISP,% What to Check for Page Page Page Calibrate Natural Special TestsTime Time NaturalCycles Last Printed 11/01/90 Material Usage InformationPARAMETER, PRT Date Time Totals Grand PCT CurrentPart IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function CNT OFF Load Cell RAW Signal ReadoutCNT Results to Expect Clear ALL Restart Clear RoutineCore Dump Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Full Recalibration of Load CellsZero WaitWeigh Bins Blender Preventive MaintenanceDispense Gates Load CellsThese Instructions for Totalizers only Totalize Special Totalizer FunctionStop END of Cycle BlenderComputer Outputs Wiring Supplement Call Appendix A-2 Gravimetric Batch Blenders Autoweigh GBM Series Models SpecificationsTOP View Front View Side View Gravimetric Batch Blenders AutoWeigh GB100 Series ModelsGravimetric Batch Blenders GB 220 and 420 Models 120V/1 phase/50-60 Hz 240V/1 phase/50-60 HzTOP View Mounting Interface Gravimetric Batch Blenders AutoWeigh GB240 and GB440 Models2124 Gravimetric Batch Blenders AutoWeigh GB900 Series ModelsGB1840 GB1860 Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 ModelsControl Remote Mounted Models WSBM22 WSBM131 WSBM140 Gravimetric Batch Blenders Wsbm Series modelsSide View Front View Side View, R Model Front View, R Model Gravimetric Batch Blenders WSB 100 and 100R Models24.4 Gravimetric Batch Blenders WSB 220 and 420 ModelsWSB442 Gravimetric Batch Blenders WSB 240/440 and 240/440R ModelsGravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C