PARAMETERS
All WEIGH SCALE BLENDER controllers operate according to certain internal PARAMETERS. Because customer requirements vary widely, we have made over 60 parameters accessible for change through the keypad.
BRIEF explanations are given first. FULL information is given in the section that follows.
NOTE: Values shown here are initial ROM values of a model 220. Initial values for other models are listed at the end of this section.
Parameters are five digits, with leading zeros added.
TIMES are expressed as seconds, minutes, or interrupts. (244 interrupts = 1 second).
WEIGHTS are always expressed as GRAMS.
100 and 200 models use tenths of grams: (xxxx.x). (00010 = 1 gram)
400, 900, and 1800 models; full grams: (xxxxx). (00050 = 50 grams)
PERCENTS are expressed in tenths for settings (0xxx.x),
and full percents for other percentage references (00xxx).
======================================================================
PARAMETER LIST - BRIEF EXPLANATIONS
FLG 00000 turns on the RECIPE, BATCH, FAST, and TAG keys.
These four keys will NOT WORK unless you set this parameter.
The | RECIPE key is for | storing up to 99 recipes. | |
The | BATCH key allows for filling a barrel or gaylord. | ||
The | FAST key | allows a | higher output mode. |
The | TAG key adds certain information to all printouts. | ||
RPO 00000 | Pulsed Output, | timing of ON/OFF pulses. | |
NPO 00000 | (Reg, | Nat, Col, Add). | |
CPO 00000 | Set only for Micro Pulse equipped slide gates. | ||
APO 00000 |
|
|
|
MPO 00010 | Pulsed output to the mixer motor | ||
RAL 00000 | Last digit = number of retries before ALARM. | ||
NAL 00004 | 00001 | to 00009 | = sound alarm, hold process. |
CAL 00004 | 00011 | to 00019 | = sound alarm, continue process. |
AAL 00004 | 00000 | = no alarm, no retries. |
These parameters set ALARM | functions. |
|
| |||||
When material runs out, | or | does | not | dispense | fully, these flags | |||
instruct the | controller | what to | do. | Default | settings shown | are | ||
for | Natural, | Color, and | Additive to | alarm, but not Regrind. |
| |||
MIX 00015 | MIX TIME |
|
|
|
|
|
|
This parameter times how long the MIX motor runs in seconds.
Page 44