Occasionally, the system gets STUCK doing retries of a component but the retry time is so short that nothing gets dispensed.

*The LAG TIME parameter is set for too short a time. See KEYPAD, TIME, and PARAMETER, _LA.

*The dispense valve is sticking, slightly delaying it's opening.

The time period is too short for the valve to begin moving.

The system USED TO WORK but now it does unexplainable things.

*Static or a voltage surge has altered RAM memory. Do a CLEAR or CLEAR ALL. See "CLEAR" RESTART or "CLEAR ALL" RESTART.

After a "CLEAR ALL", LOAD CELL CALIBRATION is necessary.

The Display reads 3100.0 even with the bin empty. This is the upper limit load cell readout.

*The Load Cells are not plugged in and the circuitry has drifted to the top limit.

*The load cells have been overloaded way beyond their limit and are now permanently deflected.

Dispenses from a slide gate are not as consistent as they should be. *

The slide gate is sticking slightly. With the hopper empty, move the slide manually to see that it moves freely. Press up or down on the air cylinder to adjust for proper alignment.

*The material does not flow very well. A bridge breaker adaptor may be required.

Load Cell weight readings are not holding steady. They vary as much as 100 grams from second to second.

*This is static and improper grounding. See WIRING CONSIDERATIONS

*If readings drift slowly in one direction, requiring frequent recalibration, a component on the circuit board is most likely faulty. Call us.

*If TARE weights are not steady, something may be physically interfering with free movement of the cells.

The Weigh Bin dump valve does not stay open long enough for the bin to empty fully.

*The air flow control valve is adjusted too far in and the valve opens too slowly. This should be adjusted to slow the closing just enough to prevent excessive banging.

*The DTI parameter is not set for enough dump time. This parameter controls Dump Time (DTI). Recommended times are 2000 grams = 6 sec.; 4000 grams = 10 sec.; 9000 grams = 4 sec. Entries are in seconds. See PARAMETERS for more information.

The MIX MOTOR runs when set to ON but not when set to TIMED.

*The fuse on the RELAY circuit board is blown. See hardware maintenance for replacement instructions.

Page 82

Image 81
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Part Hardware Maintenance Part Troubleshooting / SoftwareFour Component Software Part OperationCheck OUT Procedure Assembly InstructionsSpecial Features Proceed to Safety Hazards NextSafety Features Safety Interlock Switch Safety Hazards MIX BladesProceed to Assembly Next Additional MIX Blade HazardDisclaimers Load Cells are Easily Damaged Part AssemblyPlease Be Careful On the NextPage Proceed to Check OUT Procedure Next Wiring ConsiderationsTurn Power on Procedure What should Happen Plug in ControllerAT this Point Touch Weigh BIN Very LightlyPress REG KEY Press Alarm KEYLED # Press NAT KEYPage Exit PasswordBe Sure Part Operation Load Cell CalibrationCAL OFF CALOper Proceed to Normal Operation NextOperate COLMicro Pulse Selected Models Special InstructionsGB/WSB MB GB/WSB 240RPower OFF If Problems DevelopPower on Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind ROM OK Eight Character DisplayStrobe Light and Beeper Alarms Right Column AlarmsAlarm Silence LED LightsMixer Motor ON/OFF/TIMED Switch Mixer Motor OutletMixer Motor Fuse Keypad Internal FusesDate Recipe Keypad Automatic Operation ModeRUN RCPSave BtchTABLE, FLG Page TAG FastALL Keypad Manual ModeTime ADD TimedPage Keypad Program Mode Para Star FunctionsYLD Ctrl Page Page Page Page Page Page Page Page Parameters Parameter List Brief ExplanationsMIX Time XXX RLO Page CPL Full Explanation of Parameters MPO No ALARM, no RetriesMIX BER KDF / WDFPage ROV Page Example RHL is Set 10 percent Page SET SettingPage Page Page Page Page XCV + XRC TCV + TRCXTP XUL XALPTD LIQMCT Page FLG RPO NPO CPO Parameter Default Settings Four SoftwareAPO MPO RAL NAL CAL AAL MIX JOGRTI NPT CPT APT RWTNWT NTIChanging Parameters Prnt Prnt OFFREG Natural COL TotalFinal DISP,% What to Check for Page Page Page Time Special TestsTime Natural Calibrate NaturalPARAMETER, PRT Material Usage InformationDate Time Totals Grand PCT Current Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function Load Cell RAW Signal Readout CNT OFFCNT Results to Expect Clear Routine Clear ALL RestartCore Dump Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Zero Recalibration of Load CellsWait FullDispense Gates Blender Preventive MaintenanceLoad Cells Weigh BinsThese Instructions for Totalizers only Stop END of Cycle Special Totalizer FunctionBlender TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Gravimetric Batch Blenders Autoweigh GBM Series Models SpecificationsTOP View Front View Side View Gravimetric Batch Blenders AutoWeigh GB100 Series ModelsGravimetric Batch Blenders GB 220 and 420 Models 120V/1 phase/50-60 Hz 240V/1 phase/50-60 HzTOP View Mounting Interface Gravimetric Batch Blenders AutoWeigh GB240 and GB440 Models2124 Gravimetric Batch Blenders AutoWeigh GB900 Series ModelsGB1840 GB1860 Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 ModelsControl Remote Mounted Models WSBM22 WSBM131 WSBM140 Gravimetric Batch Blenders Wsbm Series modelsSide View Front View Side View, R Model Front View, R Model Gravimetric Batch Blenders WSB 100 and 100R Models24.4 Gravimetric Batch Blenders WSB 220 and 420 ModelsWSB442 Gravimetric Batch Blenders WSB 240/440 and 240/440R ModelsGravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C