the WEIGH SCALE BLENDER is to dispense materials in the proper ratios. Because all components are weighed by the same load cells, the accuracy of these ratios is not affected by zero or full scale errors.
STAR FUNCTIONS available in this mode.
*00 Press (*,0,0) to CLEAR ALL DATA fields. These are the material usage totals that are viewed with the VIEW key. If you are tracking material usage WITHOUT a computer, you may wish to reset them to zero on a regular basis for simplicity of calculations. If you are using a computer to gather and track totals, DO NOT clear these totals. The computer software will most likely loose data if you do.
After VIEWING the data or printing the data using the VIEW,* key sequence, a display of (00=CLEAR) will appear for 5 seconds. During this 5 seconds you may reset all data fields to zero by pressing 00. Pressing any other key will exit this sequence without clearing data.
*99 Press (*,9,9) to set flag to enable Weight Calibration of the Load Cells. This flag must be ON before the load cell weight calibration keys, ZERO and FULL WT, will function.
Use the * key to toggle flag ON or OFF.
Power On will always set this flag to OFF.
Press EXIT when desired flag status is displayed.
KEYPAD - PROGRAM MODE
In this mode, you may perform ALL of the functions available in MANUAL mode, plus additional functions that alters the logic with which the controller operates.
The PARA (PARAMETER) key operates in this mode. The SET key has additional functions.
STAR FUNCTIONS are available by pressing the * key and two numbers.
Just as with the MANUAL mode, you can enter this mode only when the controller is between cycles. The sensor must be covered or the sensor control switch must be in the "STOP - END OF CYCLE" position. When in this mode, no automatic dispensing will occur.
TO ENTER THIS MODE: press "*", then enter the correct password number. The correct password supplied with the unit is "22222". To change this to another 5 digit number of your choice, see (*78). When in the PROGRAM mode, the letter "P" shows at the left end of the display.
The following PROGRAM functions are available in the PROGRAM mode.
SETTING: Press the SET key once followed by one of 3 keys: REG, COL,
(SET) or ADD. The current thumbwheel setting will be displayed. If the keypad, or a computer, was used to enter this setting then it may not match the thumbwheel setting.
Page 34