Conair GB/ WSB manual Keypad Automatic Operation Mode, Recipe, Run, Rcp

Page 26

Three (3) operation Modes are available; AUTOMATIC, MANUAL, PROGRAM.

KEYPAD - AUTOMATIC OPERATION MODE

This is the NORMAL operating mode. When power is turned on, the unit is in this mode. Automatic dispensing occurs ONLY in this mode. The AUTOMATIC mode is indicated by the ABSENCE of the letter "P" or "M" at the left end of the display.

Only the VIEW, RECIPE, BATCH, FAST, TAG, *, CE, and EXIT keys are available in this mode.

These keys operate BETWEEN cycles only or when the PAUSE switch is on. To stop between cycles, use the "OFF AT END OF CYCLE" switch.

VIEW DATA: Press to display the CURRENT Date and Time, LAST CLEARED

(VIEW) date and time, and stored material usage data. Six totals are available: (in Pounds, Kilos, Grams, or Ounces)

Number of CYCLES that have occurred:

(CY= #####)

Weight of REGRIND that has been dispensed:

(R = #####)

Weight of NATURAL:

(N = #####)

Weight of COLOR:

(C = #####)

Weight of ADDITIVE:

(A = #####)

Total weight of ALL materials:

(T = #####)

Each successive press of the VIEW key displays the next total. The last displayed line will say (00=CLEAR) for 5 seconds. During this time, you may press 0,0 to clear the data. Waiting 5 seconds or pressing any other key will exit the sequence. When the sequence is exited, normal automatic operation resumes. These totals may be displayed as pounds, grams, kilograms, or ounces by a selection procedure explained later (*89).

Press the VIEW key once followed by the "*" key to cause all information to be sent to the printer (if available). To then clear the data, press 00 within 5 seconds. Press any other key or, wait 5 seconds, to continue the process without clearing the totals.

RECIPE:

This key

allows you to LOOK at,

RUN,

and SAVE RECIPES.

(RCP)

To SAVE a recipe you must be in

the PROGRAM mode. Recipes

 

are thumbwheel

switch settings.

100

recipes may be stored,

 

numbered

00 to

99.

 

 

This key is NOT FUNCTIONAL unless the 3rd digit of the "FLG" parameter is set to 1 (xx1xx). To do this, see the SOFTWARE MAINTENANCE section, PARAMETER TABLE, "FLG".

In normal

Automatic

mode:

Press RCP key.

If no

RECIPE

is

currently

in

use,

display says (GET

__).

If a

RECIPE

is

currently

in

use then display

will flash through

the current

stored data:

 

 

 

 

 

 

 

 

 

(RCP

__), (R

=

xx ),

(C

= xx.x), (A = xx.x)

 

 

Press CE to CLEAR CURRENT RECIPE and return to thumbwheels.

Page 27

Image 26
Contents Gravimetric Blenders Date Manual Number UGB006/1103 Serial numbers Model numbers Four Component Software Part Troubleshooting / SoftwarePart Hardware Maintenance Part OperationSpecial Features Assembly InstructionsCheck OUT Procedure Proceed to Safety Hazards NextProceed to Assembly Next Safety Hazards MIX BladesSafety Features Safety Interlock Switch Additional MIX Blade HazardDisclaimers Please Be Careful Part AssemblyLoad Cells are Easily Damaged On the NextPage Wiring Considerations Proceed to Check OUT Procedure NextAT this Point Procedure What should Happen Plug in ControllerTurn Power on Touch Weigh BIN Very LightlyLED # Press Alarm KEYPress REG KEY Press NAT KEYPage Password ExitCAL OFF Part Operation Load Cell CalibrationBe Sure CALOperate Proceed to Normal Operation NextOper COLGB/WSB MB Selected Models Special InstructionsMicro Pulse GB/WSB 240RPower on If Problems DevelopPower OFF Instructions for Normal OperationNormal Operating Sequence Each Cycle Exit Regrind Eight Character Display ROM OKAlarm Silence Right Column AlarmsStrobe Light and Beeper Alarms LED LightsMixer Motor Fuse Mixer Motor ON/OFF/TIMED SwitchMixer Motor Outlet Internal Fuses KeypadDate RUN Keypad Automatic Operation ModeRecipe RCPTABLE, FLG SaveBtch Page Fast TAGKeypad Manual Mode ALLTimed Time ADDPage Keypad Program Mode YLD Ctrl ParaStar Functions Page Page Page Page Page Page Page Page MIX Time ParametersParameter List Brief Explanations XXX RLO Page CPL Full Explanation of Parameters No ALARM, no Retries MPOMIX KDF / WDF BERPage ROV Page Example RHL is Set 10 percent Page Setting SETPage Page Page Page Page XTP XCV + XRCTCV + TRC XAL XULMCT PTDLIQ Page APO Parameter Default Settings Four SoftwareFLG RPO NPO CPO MPO RAL NAL CAL AAL MIX JOGNWT NPT CPT APT RWTRTI NTIChanging Parameters REG Natural COL Prnt OFFPrnt TotalFinal DISP,% What to Check for Page Page Page Time Natural Special TestsTime Calibrate NaturalDate Time Totals Grand PCT Current Material Usage InformationPARAMETER, PRT Cycles Last Printed 11/01/90Part IV Troubleshooting What to do Increasing Throughput Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function CNT Load Cell RAW Signal ReadoutCNT OFF Results to Expect Core Dump Clear RoutineClear ALL Restart Weigh BIN Dump Valve Soft Close Clean OUT Issues MIX Problems Page Wait Recalibration of Load CellsZero FullLoad Cells Blender Preventive MaintenanceDispense Gates Weigh BinsThese Instructions for Totalizers only Blender Special Totalizer FunctionStop END of Cycle TotalizeComputer Outputs Wiring Supplement Call Appendix A-2 Specifications Gravimetric Batch Blenders Autoweigh GBM Series ModelsGravimetric Batch Blenders AutoWeigh GB100 Series Models TOP View Front View Side View120V/1 phase/50-60 Hz 240V/1 phase/50-60 Hz Gravimetric Batch Blenders GB 220 and 420 ModelsGravimetric Batch Blenders AutoWeigh GB240 and GB440 Models TOP View Mounting InterfaceGravimetric Batch Blenders AutoWeigh GB900 Series Models 2124Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 Models GB1840 GB1860Gravimetric Batch Blenders Wsbm Series models Control Remote Mounted Models WSBM22 WSBM131 WSBM140Gravimetric Batch Blenders WSB 100 and 100R Models Side View Front View Side View, R Model Front View, R ModelGravimetric Batch Blenders WSB 220 and 420 Models 24.4Gravimetric Batch Blenders WSB 240/440 and 240/440R Models WSB442Gravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C