Henny Penny 680 KFC manual Reset Usage, Mode, Factory Presets F/C, Gas/Electric, Speaker Volume

Page 107

Henny Penny

 

Model 680

SMS SPECIAL PROGRAM

 

Reset Usage

MODE (Continued)

1.

Press and hold the Function button for two seconds

 

 

until “REG PROGRAM” shows in the display. As soon

 

 

as “REG PROGRAM” shows in the display, press and

 

 

release the Function button 2 times until “RESET USE”

 

 

shows in the display.

 

2.

When “CODE” shows in the display, press 1-3-5.

 

 

“DAILY will show in the display, and press any of the

 

 

Product buttons to reset them to 0.

 

 

Factory Presets (F/C, Gas/Electric, Speaker Volume,

 

 

Speaker Frequency, Codes, Initialize System)

 

1.

Press and hold the Function button for two seconds until

 

 

“REG PROGRAM” shows in the display. As soon as

 

 

“REG PROGRAM” shows in the display, press and

 

 

release the Function button 3 times until “FAC PRESET”

 

 

shows in the display.

 

2.

When “CODE” shows on the display, enter 2957.

 

 

“DEG” and “MODE” flashes in the display. Press any of

 

 

the product buttons to toggle from ºF to ºC, vice versa.

 

3.

Press and release the Function button and “TYPE”

 

 

and “FRYR” flashes in the display. Press any of the

 

 

product buttons to toggle from “GAS” to “ELEC”, or vice

 

 

versa.

 

4.

Press and release the Function button twice, and “SPKR”

 

 

and “VOL” flashes in the display. The volume can be

 

 

changed from 01 to 10, 10 being the loudest.

 

5.

Press and release the Function button 3 times, and

 

 

“SPKR” and “FREQ” will flash in the display. The

 

 

frequency can be set from 100 to 2000.

 

6.

Press and release the Function button 10 times, and

 

 

“INTITIALIZE SYSTEM” scrolls across the display.

 

 

Press and hold any of the Product buttons and the display

will count down from 5. Once the display counts down, release the Product button, and the control will set factory preset parameters into the controls.

NOTE

Before attempting to change the other modes in the

Factory Preset mode, please call Technical Service

Department at Henny Penny. 1-800-417-8405.

6-34

1005

Image 107
Contents Page Henny Penny 8 Head GAS Pressure Fryer SpecificationsPage Page Limited Warranty for Henny Penny Appliances Introduction Section Heat IntroductionPressure Fryer PressurePage Page Page Prop UP a Ramp for Each Caster on the Selected Side Insert Page Page Page ALL STR N Unit again after installation Shortening MAY Start UP Procedure Lever Is not to be Pulled Page Page Push handle back and raise lid Melt Cycle Operation Switches IndicatorsLo Mode Cool ModeHeat Light will illuminate whenever the control calls for Page Refer to KFC’s Standards Library on cleaning instructions Page 397 Connecw Hj i’.,‘i ,e.*f Page Product Color Not Correct Too Dark Spotted Rancid Taste Shortening Too old Pressure will not Eplace pressure plate Replace module Heating of shortening too slow Or boil Water Shortening Ing over Gasket coming out of lid Pressure System Page Page Pump Position Check from Page Every 90 days Complete ControlPanel Henny Penny Pressure RegulationPage Page Page Pressure PAD LID Counterweight CONT’DLID Adjustment Hertz Page Operating Control Valve ReplacementSolenoid Valve SeatOperating Control Do not Manuallyactivate the SafetyRemoval & Cleaning Safety ValveCalibration Steps Do not Disassemble or Modify this VavlePressure Gauge Page Page Page Page Page Page Page Page Page Using 3/8 socket, remove nut securing ground wire If no red glow is seen, proceed with the following Page Page Page Epyg-ui nuebq plea ewy Page Page Page Page Product One Part PER Number Description Assy UnitsLatch Plate PANEL, Right Side Page Not Avail Page Carriage Counterweight BARPart PER Number Description CableHenny Penny Model 1005 CAM Slide Filler LinkageassemblyUnits Part PER Number Description Assy LID Instruction LabelPage 705 Page Pipe ELBOW, 1/4 Dead WeightFitting Connector Pressure GaugePage HI-LIMIT LINK, Drain RODSUPPORT, Drain ROD BRACKET, HI-LIMITPage Units Smooth and Rounded Edge of Blade HOUSING, Coil Solenoid ValveassemblyCORE, Disc Assembly COVER, Coil HousingHead GAS Cooker I I SIE IAy--4A-+-7 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 Code SMS ProgrammingIfApplicable After the load compensation, press and release the Func Mode SMS Special ProgramReview Usage Speaker Frequency, Codes, Initialize System Reset UsageFactory Presets F/C, Gas/Electric, Speaker Volume ModeHeat Control Tech I/O ModeAppliance Test Press and release the Function button and MELT, Mode