5.Remove capillary bulb from bulb holder inside the cookpot.

6.Straighten the capillary tube.

7.Remove larger outside nut that threads into pot wall.

8.Remove the two nuts securing the high limit bracket at the front of the fryer, and remove bracket.

9.Remove the two screws that secure high limit to the high limit bracket.

10.Remove defective control from control panel area.

11.Insert new control and replace screws.

12.Uncoil capillary line, starting at capillary tube, and insert through cookpot wall.

To avoid electrical shock or other injury, the capillary line must run under and away from all electrical power wires and terminals. The tube must NEVER be in such a position where it could accidentally touch the elec- trical power terminals.

13.Carefully bend the capillary tube as shown in photo and place into bulb brackets.

14.Pull excess capillary line from pot and tighten nut into cookpot wall.

Be sure capillary bulb of high limit is positioned as not to interfere with carrier or when cleaning the cookpot wall, or damage to capillary tube could result.

15.With excess capillary line pulled out, tighten smaller nut.

16.Replace front panel.

17.Refill with shortening.

Image 44
Contents Page Specifications Henny Penny 8 Head GAS Pressure FryerPage Page Limited Warranty for Henny Penny Appliances Introduction Section Introduction Pressure FryerPressure HeatPage Page Page Prop UP a Ramp for Each Caster on the Selected Side Insert Page Page Page ALL STR N Unit again after installation Shortening MAY Start UP Procedure Lever Is not to be Pulled Page Page Push handle back and raise lid Switches Indicators Lo ModeCool Mode Melt Cycle OperationHeat Light will illuminate whenever the control calls for Page Refer to KFC’s Standards Library on cleaning instructions Page 397 Connecw Hj i’.,‘i ,e.*f Page Product Color Not Correct Too Dark Spotted Rancid Taste Shortening Too old Pressure will not Eplace pressure plate Replace module Heating of shortening too slow Or boil Water Shortening Ing over Gasket coming out of lid Pressure System Page Page Pump Position Check from Page Complete Control Panel Henny PennyPressure Regulation Every 90 daysPage Page Page LID Counterweight CONT’D Pressure PADLID Adjustment Hertz Page Replacement Solenoid ValveSeat Operating Control ValveDo not Manuallyactivate the Safety Removal & CleaningSafety Valve Operating ControlCalibration Steps Do not Disassemble or Modify this VavlePressure Gauge Page Page Page Page Page Page Page Page Page Using 3/8 socket, remove nut securing ground wire If no red glow is seen, proceed with the following Page Page Page Epyg-ui nuebq plea ewy Page Page Page Page Product One Units Part PER Number Description AssyLatch Plate PANEL, Right Side Page Not Avail Page Counterweight BAR Part PER Number DescriptionCable CarriageHenny Penny Model 1005 Linkageassembly Units Part PER Number Description AssyLID Instruction Label CAM Slide FillerPage 705 Page Dead Weight Fitting ConnectorPressure Gauge Pipe ELBOW, 1/4Page LINK, Drain ROD SUPPORT, Drain RODBRACKET, HI-LIMIT HI-LIMITPage Units Smooth and Rounded Edge of Blade Solenoid Valveassembly CORE, Disc AssemblyCOVER, Coil Housing HOUSING, CoilHead GAS Cooker I I SIE IAy--4A-+-7 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 Code SMS ProgrammingIfApplicable After the load compensation, press and release the Func Mode SMS Special ProgramReview Usage Reset Usage Factory Presets F/C, Gas/Electric, Speaker VolumeMode Speaker Frequency, Codes, Initialize SystemHeat Control Tech I/O ModeAppliance Test Press and release the Function button and MELT, Mode