Henny Penny 680 KFC manual Hertz

Page 53

With the carrier and racks installed on the lid, the lid should stay down, in contact with the pot rim, when the lid is lowered. The user will then be able to lock the lid in place. If the lid has a tendency to rise up before getting the lid locked down, the magnet plate probably needs adjusting. Follow these steps:

1.Remove the six nuts securing the back shroud and remove back shroud.

2.Loosen the bottom nut under the plate and unscrew both nuts a couple turns, then lower the lid again to see if the lid stays down. If not, repeat procedure.

3.Tighten lower nut up against the other nut and install back shroud - adjustment is now complete.

This is an electromechanical device that causes pressure to be held in the cookpot. The solenoid valve closes at the beginning of the cook cycle and opens automatically at the end of the cook cycle. If this valve should become dirty, or the Teflon seat nicked, pressure will not build up. The electric fryer uses a 208/240 volt, 60 hertz coil (50 hertz internationally). The gas uses a 120 volt, 60 hertz coil (208/240 volt, 50 hertz internationally).

Before starting repair procedures! move the Power/Pump Switch to the “OFF” position. Discon- nect main circuit breaker at the circuit breaker box and/or unplug service cord from the wall receptacle or electrical shock could result.

Remove the solenoid wires from the wire nuts which are found behind the control panel. Check across wires.

 

 

 

RESULTS

208/240 Volt,

60

Hertz

150 Ohms

208/240 Volt,

50

Hertz

230 Ohms

120 Volt, 60 Hertz

50 Ohms

Image 53
Contents Page Henny Penny 8 Head GAS Pressure Fryer SpecificationsPage Page Limited Warranty for Henny Penny Appliances Introduction Section Pressure Fryer IntroductionPressure HeatPage Page Page Prop UP a Ramp for Each Caster on the Selected Side Insert Page Page Page ALL STR N Unit again after installation Shortening MAY Start UP Procedure Lever Is not to be Pulled Page Page Push handle back and raise lid Lo Mode Switches IndicatorsCool Mode Melt Cycle OperationHeat Light will illuminate whenever the control calls for Page Refer to KFC’s Standards Library on cleaning instructions Page 397 Connecw Hj i’.,‘i ,e.*f Page Product Color Not Correct Too Dark Spotted Rancid Taste Shortening Too old Pressure will not Eplace pressure plate Replace module Heating of shortening too slow Or boil Water Shortening Ing over Gasket coming out of lid Pressure System Page Page Pump Position Check from Page Panel Henny Penny Complete ControlPressure Regulation Every 90 daysPage Page Page Pressure PAD LID Counterweight CONT’DLID Adjustment Hertz Page Solenoid Valve ReplacementSeat Operating Control ValveRemoval & Cleaning Do not Manuallyactivate the SafetySafety Valve Operating ControlCalibration Steps Do not Disassemble or Modify this VavlePressure Gauge Page Page Page Page Page Page Page Page Page Using 3/8 socket, remove nut securing ground wire If no red glow is seen, proceed with the following Page Page Page Epyg-ui nuebq plea ewy Page Page Page Page Product One Part PER Number Description Assy UnitsLatch Plate PANEL, Right Side Page Not Avail Page Part PER Number Description Counterweight BARCable CarriageHenny Penny Model 1005 Units Part PER Number Description Assy LinkageassemblyLID Instruction Label CAM Slide FillerPage 705 Page Fitting Connector Dead WeightPressure Gauge Pipe ELBOW, 1/4Page SUPPORT, Drain ROD LINK, Drain RODBRACKET, HI-LIMIT HI-LIMITPage Units Smooth and Rounded Edge of Blade CORE, Disc Assembly Solenoid ValveassemblyCOVER, Coil Housing HOUSING, CoilHead GAS Cooker I I SIE IAy--4A-+-7 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 Henny Penny Model 501 Code SMS ProgrammingIfApplicable After the load compensation, press and release the Func Mode SMS Special ProgramReview Usage Factory Presets F/C, Gas/Electric, Speaker Volume Reset UsageMode Speaker Frequency, Codes, Initialize SystemHeat Control Tech I/O ModeAppliance Test Press and release the Function button and MELT, Mode