The blower motor circulates air into the burner area to create the correct heat for the fryer. If the blower fails, a sensor will shut the power control valve down.
1. Remove the electrical power supplied to the unit.
Remove electrical power supplied to the unit by unplug- ging the unit, or by turning off the wall circuit breaker, or electrical shock could result.
1.Remove both side panels.
2.Remove the nut from the ground wire and remove ground wire.
3.Disconnect wires at junction box on right, back of fryer.
4.Remove conduit fitting from the blower bracket,
5.Loosen hose clamp and remove hose from blower.
6.Remove two (2) screws from the frame which secures the bracket, and lift bracket and blower assembly from unit.
7.Remove the three (3) nuts from the back of the blower and remove the blower from bracket.
8.Replace new blower in reverse order of procedures.